In active magnetic bearing (AMB) system, the demand for reliability has been increasing, especially in high-speed applications. Failure of power electronics devices is one of primary challenges to the reliability. Among them, short-circuit is a typical failure that can lead to sustained overcurrent in the system, posing a severe threat to system stability. However, very few studies have been conducted on switch short-circuit fault-tolerant control in AMB system. Facing this problem, a general fault-tolerant strategy facing switch short-circuit is introduced in this paper. Once the short-circuit happens, the corresponding winding is controlled with constant current mode and the opposite winding is used to undertake dynamic response. The proposed method includes short-circuit failure detection, changes of relationship between leg and winding voltage in modulation, and proper fault-tolerant control based on force equivalence. Fault-tolerant control experiments show the effectiveness of the proposed approach. This approach provides high reliability for AMB system which will keep the rotor stable suspension even with power electronics devices short-circuit failure.
28 October 2024 in IEEE/ASME Transactions on Mechatronics
In active magnetic bearing (AMB) systems, the demand for reliability is extremely high owing to their specialized applications. Power electronic converter is one of the primary sources of faults that lead to AMB systems. Nonetheless, there is presently little research dedicated to fault-tolerant strategies for switching devices, particularly for short-circuit faults. In this article, a short-circuit fault-tolerant shared-bridge converter topology and control strategy are presented. First, two types of electromagnetic coils that control a single AMB axis are divided into separate sets and controlled individually using a shared-bridge topology, which helps to distribute risk. Subsequently, a detailed analysis is conducted on the control performance of shared-bridge topology in faulty mode, which clarifies the rationality of current reversal and the converter's ability to control constant currents. Then, based on the characteristics of faulty topology, a method of fault detection and a novel current distribution strategy using the principle of electromagnetic force conservation are proposed. Finally, the fault-tolerant experimental results at both standstill and rotation verify the effectiveness of the fault-tolerant strategy.
Cable-stayed bridge without backstays has great architectural aesthetic feeling in bridge design, and embodies the perfect combination of force and beauty in bridge type. It has been built in landscape bridges all over the world. The shape of cable-stayed bridge without backstays determines that its stress characteristics are different from those of conventional cable-stayed bridges, and the key points of bridge design and construction control are also different. Taking a (30+120+40)m three-span cable-stayed bridge without backstays as an example, this paper introduces the design originality, structural layout and design features of the bridge, and analyzes the control points that should be paid attention to in bridge construction, which provides guidance for bridge construction.