31 October 2019 in European Archives of Oto-Rhino-Laryngology
Purpose: To evaluate the insertion results and hearing preservation of a novel slim modiolar electrode (SME) in patients with residual hearing. Methods: We retrospectively collected the data from the medical files of 17 patients (18 ears) implanted with a SME. All patients had functional low frequency hearing (PTA (0.125–0.5 kHz) ≤ 80 dB HL). The insertion results were re-examined from the postoperative cone-beam computed tomography scans. Postoperative thresholds were obtained at the time of switch-on of the sound processors (mean 43 days) and at latest follow-up (mean 582 days). The speech recognition in noise was measured with the Finnish matrix sentence test preoperatively and at follow-up. Results: The mean insertion depth angle (IDA) was 395°. Neither scala dislocations nor tip fold over were detected. There were no total hearing losses. Functional low-frequency hearing was preserved in 15/18 (83%) ears at switch-on and in 14/17 (82%) ears at follow-up. According to HEARRING classification, 55% (10/18) had complete HP at switch-on and 41% (7/17) still at follow-up. Thirteen patients (14 ears) were initially fitted with electric–acoustic stimulation and seven patients (8 ears) continued to use it after follow-up. Conclusions: The preliminary hearing preservation results with the SME were more favorable than reported for other perimodiolar electrodes. The results show that the array may also be feasible for electro-acoustic stimulation; it is beneficial in that it provides adequate cochlear coverage for pure electrical stimulation in the event of postoperative or progressive hearing loss.
27 November 2021 in European Archives of Oto-Rhino-Laryngology
Purpose: There is only limited data on the application of virtual reality (VR) for the evaluation of temporal bone anatomy. The aim of the present study was to compare the VR environment to traditional cross-sectional viewing of computed tomography images in a simulated preoperative planning setting in novice and expert surgeons. Methods: A novice (n = 5) and an expert group (n = 5), based on their otosurgery experience, were created. The participants were asked to identify 24 anatomical landmarks, perform 11 distance measurements between surgically relevant anatomical structures and 10 fiducial markers on five cadaver temporal bones in both VR environment and cross-sectional viewings in PACS interface. The data on performance time and user-experience (i.e., subjective validation) were collected. Results: The novice group made significantly more errors (p < 0.001) and with significantly longer performance time (p = 0.001) in cross-sectional viewing than the expert group. In the VR environment, there was no significant differences (errors and time) between the groups. The performance of novices improved faster in the VR. The novices showed significantly faster task performance (p = 0.003) and a trend towards fewer errors (p = 0.054) in VR compared to cross-sectional viewing. No such difference between the methods were observed in the expert group. The mean overall scores of user-experience were significantly higher for VR than cross-sectional viewing in both groups (p < 0.001). Conclusion: In the VR environment, novices performed the anatomical evaluation of temporal bone faster and with fewer errors than in the traditional cross-sectional viewing, which supports its efficiency for the evaluation of complex anatomy.
22 September 2020 in European Archives of Oto-Rhino-Laryngology
Purpose: Consumer-grade virtual reality (VR) has recently enabled various medical applications, but more evidence supporting their validity is needed. We investigated the accuracy of simulated surgical planning in a VR environment (VR) with temporal bones and compared it to conventional cross-sectional image viewing in picture archiving and communication system (PACS) interface. Methods: Five experienced otologic surgeons measured significant anatomic structures and fiducials on five fresh-frozen cadaveric temporal bones in VR and cross-sectional viewing. Primary image data were acquired by computed tomography. In total, 275 anatomical landmark measurements and 250 measurements of the distance between fiducials were obtained with both methods. Distance measurements between the fiducials were confirmed by physical measurement obtained by Vernier caliper. The experts evaluated the subjective validity of both methods on a 5-point Likert scale qualitative survey. Results: A strong correlation based on intraclass coefficient was found between the methods on both the anatomical (r > 0.900) and fiducial measurements (r > 0.916). Two-tailed paired t-test and Bland–Altman plots demonstrated high equivalences between the VR and cross-sectional viewing with mean differences of 1.9% (p = 0.396) and 0.472 mm (p = 0.065) for anatomical and fiducial measurements, respectively. Gross measurement errors due to the misidentification of fiducials occurred more frequently in the cross-sectional viewing. The mean face and content validity rating for VR were significantly better compared to cross-sectional viewing (total mean score 4.11 vs 3.39, p < 0.001). Conclusion: Our study supports good accuracy and reliability of VR environment for simulated surgical planning in temporal bones compared to conventional cross-sectional visualization.
9 August 2011 in Sleep and Breathing
30 January 2024 in Journal of Drug Delivery Science and Technology