Jaemin Kim

Jaemin Kim

Auto-generated profile, based on publicly available information

Jaemin Kim

Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
UBUijong Bong
Uijong Bong
SASoobin An
Soobin An
JVJohn Voccio
John Voccio
JKJaemin Kim
Jaemin Kim
JLJung Tae Lee
Jung Tae Lee
SHSeungyong Hahn
Seungyong Hahn
This paper presents a design study on a 40 MW synchronous motor having no-insulation (NI) high temperature superconductor (HTS) field coils. An in-house analytic code was used to obtain a first-cut design based on the published parameters of the AMSC 36.5 MW ship propulsion motor as a reference. Then, design refinement was followed using the finite element method to more accurately simulate electromechanical behaviours of the motor. After the final design was completed, transient torque responses of the NI motor, in no load and full load conditions, were simulated with our new equivalent circuit model to consider the non-linear behaviours of the NI field coils, and compare the results with those of its insulated counterpart. The overall torque response of the NI machine is essentially identical to that of the insulated one, though a notable discrepancy was observed at the moment when the rotor acceleration started and ended. The results may imply that the NI field coils play a role as an effective damper in perspective of the torque response. The results demonstrate a potential to use the NI HTS field coils for a low-speed synchronous machine such as the ship propulsion motor.

1 February 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JKJaemin Kim
Jaemin Kim
YKYungil Kim
Yungil Kim
SYSangwon Yoon
Sangwon Yoon
KSKanghwan Shin
Kanghwan Shin
JLJunghun Lee
Junghun Lee
SHSeungyong Hahn
Seungyong Hahn
We report the design, construction, and operation results of an 18 T 70 mm cold-bore high temperature superconductor (HTS) no-insulation (NI) magnet, which is developed for an axion haloscope experiment. The magnet consists of 44 double-pancake coils wound with multi-width and multi-thickness REBa2Cu3O7−x (RE = rare earth) tapes. Owing to the NI feature, the magnet is highly compact; is 162 mm in outer diameter and 476 mm tall; and provides an environment of 0.22 T2 m3 within the cold-bore target space of 66 mm in diameter and 200 mm in length. After an initial performance test at SuNAM Co. Ltd., the magnet was installed at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science in Daejeon, South Korea, in August 2017. The magnet has been successfully operating at the CAPP since then, except for maintenance in October 2018. The magnet may represent the first high field HTS user magnet that experienced long-term operation of over one year.

18 February 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MCMincheol Cho
Mincheol Cho
SNSo Noguchi
So Noguchi
JBJeseok Bang
Jeseok Bang
JKJaemin Kim
Jaemin Kim
UBUijong Bong
Uijong Bong
SHSeungyong Hahn
Seungyong Hahn
This paper presents a "combined" circuit model to simulate non-linear behaviors of a no-insulation (NI) high temperature superconductor (HTS) coil. The key idea is a selective use of either the lumped circuit model or distributed depending on an operating condition. When the NI coil current is below its critical current, the radial leak currents through turn-to-turn contacts may be assumed to be uniformly distributed over the entire coil, thus the lumped circuit model may suffice to analyze the NI behaviors. When the coil current increases beyond the critical current, the distributed model plays the role to simulate the spatial distribution of currents, both radial and azimuthal. By limiting the use of the time-consuming distributed model only for the post-quench part, the combined model enables substantial reduction in calculation time without sacrificing simulation accuracy. To verify the validity of the combined model, an over-current charging test of an NI HTS coil was simulated with the lumped, distributed, and combined models. The simulation results of the combined model are barely discernible from those of the distributed model, and agreed well with the measured ones as well. The results validate the combined model for more efficient simulation of an NI HTS coil.

15 June 2023 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
SWShu Wang
Shu Wang
Meritxell RoviraMeritxell Rovira
Meritxell Rovira
SDSilvia Demuru
Silvia Demuru
CLCe´line Lafaye
Ce´line Lafaye
JKJaemin Kim
Jaemin Kim
SLShih-Chii Liu
Shih-Chii Liu
Sweat secreted by the human eccrine sweat glands can provide valuable biomarker information during exercise. Real-time non-invasive biomarker recordings are therefore useful for evaluating the physiological conditions of an athlete such as their hydration status during endurance exercise. This work describes a wearable sweat biomonitoring patch incorporat- ing printed electrochemical sensors into a plastic microfluidic sweat collector and data analysis that shows the real-time recorded sweat biomarkers can be used to predict a physiological biomarker. The system was placed on subjects carrying out an hour-long exercise session and results were compared to a wearable system using potentiometric robust silicon-based sensors and to commercially available HORIBA-LAQUAtwin devices. Both prototypes were applied to the real-time monitoring of sweat during cycling sessions and showed stable readings for around an hour. Analysis of the sweat biomarkers collected from the printed patch prototype shows that their real-time measurements correlate well (correlation coefficient 0.65) with other physiological biomarkers such as heart rate and regional sweat rate collected in the same session. We show for the first time, that the real-time sweat sodium and potassium concentration biomarker measurements from the printed sensors can be used to predict the core body temperature with root mean square error (RMSE) of 0.02 °C which is 71% lower compared to the use of only the physiological biomarkers. These results show that these wearable patch technologies are promising for real- time portable sweat monitoring analytical platforms, especially for athletes performing endurance exercise.

28 September 2021 in Superconductor Science and Technology
Verified
Journal Article
Closed access
GKGeonyoung Kim
Geonyoung Kim
AMAndrea Musso
Andrea Musso
JBJeseok Bang
Jeseok Bang
JLJung Tae Lee
Jung Tae Lee
CIChaemin Im
Chaemin Im
SHSeungyong Hahn
Seungyong Hahn
This paper presents a numerical method, based on the partial element equivalent circuit (PEEC) technique, for spatially-distributed and time-varying simulation to analyze nonlinear ‘defect-irrelevant’ behaviors of a no-insulation (NI) high temperature superconductor (HTS) coil. We suggest a resistivity parameterization approach in combination of the PEEC method to replicate electromagnetic dynamics of an NI HTS coil containing multiple ‘defects.’ The proposed method is adopted to investigate ‘defect-irrelevant’ behaviors of an NI single pancake coil having lap joints as a form of artificial defects. To validate our approach, electromagnetic characteristics of the NI test coil are measured in a bath of liquid nitrogen at 77 K and compared with four key simulation results: (a) local voltages; (b) current distribution; (c) magnetic field; and (d) Joule heating distribution. Experimental measurements of local voltages and the magnetic field are compared to the simulation results to validate our numerical method.

7 February 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SASoobin An
Soobin An
KCKibum Choi
Kibum Choi
SNSo Noguchi
So Noguchi
CIChaemin Im
Chaemin Im
JBJeseok Bang
Jeseok Bang
SHSeungyong Hahn
Seungyong Hahn
When a quench occurs in a no-insulation (NI) high temperature superconductor (HTS) magnet that consists of a stack of double-pancake (DP) coils, a large amount of current is often induced in an NI DP coil that is electromagnetically coupled with neighboring DP coils. The large induced current leads to an excessive magnetic stress and occasionally damages the magnet. In this paper, we propose a new quench protection concept to reduce the amount of induced current in an NI HTS magnet. The key idea is to use resistive copper in order to absorb a portion of electromagnetic energy that is initially stored in the magnet before the quench. We tentatively name these resistive coils as a "magnetic dam," as they may slow down the electromagnetic quench propagation speed among the NI DP coils, which may be beneficial to avoid over-stressing by the large over-current.