Electrolyzers are recognized as promising equipment to improve power systems' operation flexibility. However, existing electrolyzer models used in power system operation optimization are either nonconvex or inaccurate when operating over a broad temperature range. Hence, this letter proposes an enhanced feasible operational area of electrolyzer (EFOAE) model. The EFOAE model is the first model that is convex and accurate over a broad temperature range (0 ${}^{\circ }$ C-80 ${}^{\circ }$ C). Therefore, the EFOAE model is favorable for operation optimization of the power systems with high penetration of renewables. Besides, to reduce errors, this letter improves the current electrolyzer feasible operational area derivation method, and removes the infeasible part in EFOAE. Compared with existing narrow temperature range (60 ${}^{\circ }$ C-80 ${}^{\circ }$ C) electrolyzer models, using EFOAE may release greater flexibility for power systems' operation, thereby reducing costs by 4.6% and wind curtailment by 63% in case studies.
28 August 2024 in IEEE Transactions on Sustainable Energy
The power-to-hydrogen-and-heat (P2HH) method is a potential means of improving energy efficiency while reducing carbon emissions. However, existing P2HH methods are ineffective at low temperatures, and do not consider physical constraints on heat exchange between the electrolyzer and heating network. Hence, this paper proposes an improved P2HH (IP2HH) method to overcome these shortcomings. First, this paper proposes a novel collaborative mechanism between the electrolyzer and the heating network. In this system, the electrolyzer can not only transfer excess heat to the heating network when at high temperatures, but can also be heated by the heating network when at low temperatures. Second, this paper takes the physical limitations of heat exchange between electrolyzer and heating network into consideration, and models the regulating valve of heat exchanger. These considerations allow produce simulation results that better approximate real-world scenarios. Finally, a convex model integrated with the IP2HH approach is established. Compared with the existing P2HH method, the IP2HH method may allow electrolyzer to work intermittently based on fluctuations in renewables supplies while maintaining high hydrogen production efficiency. Such improvements could reduce carbon emissions by 35.5%, costs by 10.7%, and renewables curtailment by 26.4% at ambient temperature of 1 $^{\circ }$ C.
Fuel cell systems (FCS) are recognized as promising electric sources of power systems. However, existing FCS models are either nonconvex or inaccurate when the FCS is under heavy load. This letter proposes a mechanism-based FCS feasible operational area (FCSFOA) model, taking into account the decline in fuel cell efficiency and the dynamic power consumption of the auxiliary system. Therefore, the FCSFOA model is accurate both under light load and heavy load, and the average error is only 5.4% compared with the actual data. In contrast, the FCS linear model, the most commonly used in the dispatch of power systems, has an average error of 24.4% . Besides, the FCSFOA model is also convex, which is favorable for the dispatch of power systems.
18 February 2026 in IEEE Transactions on Industrial Informatics
Porcelain insulators are prone to degradation, including internal defects and mechanical fractures, due to long-term exposure to harsh operational stresses. Such failures threaten the safe and reliable operation of power grids. Existing online monitoring techniques often suffer from limitations in accuracy, safety, cost, or scalability. To address these challenges, this article proposes a novel online monitoring and intelligent fault diagnosis system for porcelain insulators. A low-cost, nonintrusive device is designed to measure voltage distribution across insulator strings and transmit data wirelessly. An intelligent diagnostic algorithm based on voltage patterns is then developed to assess insulator health, issue early warnings, and pinpoint fault locations. Simulation results confirm the algorithm’s predictive accuracy, achieving a mean squared error of 0.028–0.051 and a mean absolute error of 0.058–0.098 across multiple voltage levels and environmental conditions. More critically, field deployment on live transmission lines demonstrates a fault prediction accuracy exceeding 99.5% during two months of continuous operation. These results validate both the robustness and scalability of the proposed method. This article thus provides a practical solution for predictive maintenance, offering real-time, high-precision diagnostics that significantly enhance the operational intelligence and safety of modern power grids.