Balbina Makurat-Kasprolewicz

Mrs. Balbina Makurat-Kasprolewicz

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2024 in Chemical Engineering Journal
Verified
Journal Article
Closed access
Balbina Makurat-KasprolewiczBalbina Makurat-Kasprolewicz
Balbina Makurat-Kasprolewicz
HIHossein Ipakchi
Hossein Ipakchi
PRPouya Rajaee
Pouya Rajaee
AOAgnieszka Ossowska
Agnieszka Ossowska
Aleksander HejnaAleksander Hejna
Aleksander Hejna
Mohammad Reza SaebMohammad Reza Saeb
Mohammad Reza Saeb

25 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Balbina Makurat-KasprolewiczBalbina Makurat-Kasprolewicz
Balbina Makurat-Kasprolewicz
MWMarcin Wekwejt
Marcin Wekwejt
LPLuca Pezzato
Luca Pezzato
ARAnna Ronowska
Anna Ronowska
Jolanta KrupaJolanta Krupa
Jolanta Krupa
AOAgnieszka Ossowska
Agnieszka Ossowska
Implant surgeries are increasingly challenging due to their rising number. Achieving the desired biomaterial surface properties to ensure a strong bond with human tissue is a significant issue. This study investigates the influence of ultrasound (US) during the micro-arc oxidation (MAO) process on Ti13Zr13Nb bio-alloy, an area not previously explored, to enhance titanium alloy coatings’ properties for biomedical applications. Porous calcium-phosphate-based coatings were successfully deposited on Ti13Zr13Nb using MAO and ultrasound micro-arc oxidation (UMAO). Various properties such as morphology, chemical composition, topography, wettability, surface free energy, thickness, adhesion to the substrate, as well as mechanical and corrosion characteristics were thoroughly analyzed. Cytocompatibility was assessed using human osteoblasts. Using US during the MAO process increased coating roughness (up to ~ 17%), core height (up to 22%), isotropy (up to 17%), thickness (up to ~ 46%), and hardness (up to ~ 18%), depending on MAO parameters and US mode. Optimal coating performance was achieved at 136 mA, 600 s, and a sinusoidal US setting, resulting in the highest isotropy (~ 79%) and rutile quantity (2.6%), the lowest elastic modulus (~ 57 GPa), and the contact angle of ~ 70°, all of which could have contributed to enhancing osteoblast viability in vitro. This study, for the first time, underscores the importance of using the US during the MAO in tailoring the Ti13Zr13Nb for specific biomedical applications.

31 October 2023 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Open access
Balbina Makurat-KasprolewiczBalbina Makurat-Kasprolewicz
Balbina Makurat-Kasprolewicz
AOAgnieszka Ossowska
Agnieszka Ossowska
Over the past decade, titanium implants have gained popularity as the number of performed implantation operations has significantly increased. There are a number of methods for modifying the surface of biomaterials, which are aimed at extending the life of titanium implants. The developments in this field in recent years have required a comprehensive discussion of all the properties of electrophoretically deposited coatings on titanium and its alloys, taking into account their bioactivity. The development that took place in this field in recent years required a comprehensive discussion of all the properties of coatings electrophoretically deposited on titanium and its alloys, with particular emphasis on their bioactivity. Herein, we attempt to assess the influence of the electrophoretic deposition (EPD) process parameters on these coatings' biological and mechanical properties. Particular attention has been addressed to the in‐vitro and in‐vivo studies conducted hitherto. We have seen an increased interest in using titanium alloys without the addition of toxic compounds and gaps in the EPD field such as the uncommon endeavors to develop a “Design of experiments” approach as well as the lack of assessment of the surface free energy and detailed topography of electrophoretically deposited coatings. The exact correlation of coating properties with EPD process parameters still seems explicitly not understood, necessitating more future investigations. Ipso facto, the exact mechanism of particle agglomeration and Hamaker's law need to be fathomable.

19 March 2024 in ACS Biomaterials Science & Engineering
Verified
Journal Article
Open access
Balbina Makurat-KasprolewiczBalbina Makurat-Kasprolewicz
Balbina Makurat-Kasprolewicz
Marcin WekwejtMarcin Wekwejt
Marcin Wekwejt
ARAnna Ronowska
Anna Ronowska
GGGrzegorz Gajowiec
Grzegorz Gajowiec
MGMarlena Grodzicka
Marlena Grodzicka
AOAgnieszka Ossowska
Agnieszka Ossowska
Over the past decade, bone tissue engineering has been at the core of attention because of an increasing number of implant surgeries. The purpose of this study was to obtain coatings on titanium (Ti) implants with improved properties in terms of biomedical applications and to investigate the effect of ultrasound (US) on these properties during the micro-arc oxidation (MAO) process. The influence of various process parameters, such as time and current density, as well as US mode, on the properties of such coatings was evaluated. Novel porous calcium-phosphate-based coatings were obtained on commercially pure Ti. Their microstructure, chemical composition, topography, wettability, nanomechanical properties, thickness, adhesion to the substrate, and corrosion resistance were analyzed. In addition, cytocompatibility evaluation was checked with the human osteoblasts. The properties of the coatings varied significantly, depending on applied process parameters. The US application during the MAO process contributes to the increase of coating thickness, porosity, roughness, and skewness, as well as augmented calcium incorporation. The most advantageous coating was obtained at a current of 136 mA, time 450 s, and unipolar rectangular US, as it exhibits high porosity, adequate wettability, and beneficial skewness, which enabled increased adhesion and proliferation of osteoblasts during in vitro studies. Finally, the conducted research demonstrated the influence of various UMAO process parameters, which allowed for the selection of appropriate Ti implant modification for specific biomedical utilization.

6 November 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Justyna KozlowskaJustyna Kozlowska
Justyna Kozlowska
JSJoanna Skopińska-Wiśniewska
Joanna Skopińska-Wiśniewska
BKBeata Kaczmarek-Szczepańska
Beata Kaczmarek-Szczepańska
SGSylwia Grabska
Sylwia Grabska
Balbina Makurat-KasprolewiczBalbina Makurat-Kasprolewicz
Balbina Makurat-Kasprolewicz
Marcin WekwejtMarcin Wekwejt
Marcin Wekwejt

10 November 2022 in Molecular Pharmaceutics
Verified
Journal Article
Open access
PSPatrycja Szumała
Patrycja Szumała
JKJolanta Kaplińska
Jolanta Kaplińska
Balbina Makurat-KasprolewiczBalbina Makurat-Kasprolewicz
Balbina Makurat-Kasprolewicz
SMSzymon Mania
Szymon Mania