Jolanta Krupa

Ms. Jolanta Krupa

Mechanical Engineering and Robotics, AGH University of Krakow, Kraków, Małopolskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Balbina Makurat-KasprolewiczBalbina Makurat-Kasprolewicz
Balbina Makurat-Kasprolewicz
MWMarcin Wekwejt
Marcin Wekwejt
LPLuca Pezzato
Luca Pezzato
ARAnna Ronowska
Anna Ronowska
Jolanta KrupaJolanta Krupa
Jolanta Krupa
AOAgnieszka Ossowska
Agnieszka Ossowska
Implant surgeries are increasingly challenging due to their rising number. Achieving the desired biomaterial surface properties to ensure a strong bond with human tissue is a significant issue. This study investigates the influence of ultrasound (US) during the micro-arc oxidation (MAO) process on Ti13Zr13Nb bio-alloy, an area not previously explored, to enhance titanium alloy coatings’ properties for biomedical applications. Porous calcium-phosphate-based coatings were successfully deposited on Ti13Zr13Nb using MAO and ultrasound micro-arc oxidation (UMAO). Various properties such as morphology, chemical composition, topography, wettability, surface free energy, thickness, adhesion to the substrate, as well as mechanical and corrosion characteristics were thoroughly analyzed. Cytocompatibility was assessed using human osteoblasts. Using US during the MAO process increased coating roughness (up to ~ 17%), core height (up to 22%), isotropy (up to 17%), thickness (up to ~ 46%), and hardness (up to ~ 18%), depending on MAO parameters and US mode. Optimal coating performance was achieved at 136 mA, 600 s, and a sinusoidal US setting, resulting in the highest isotropy (~ 79%) and rutile quantity (2.6%), the lowest elastic modulus (~ 57 GPa), and the contact angle of ~ 70°, all of which could have contributed to enhancing osteoblast viability in vitro. This study, for the first time, underscores the importance of using the US during the MAO in tailoring the Ti13Zr13Nb for specific biomedical applications.

8 November 2025 in Ceramics International
Verified
Journal Article
Closed access
Balbina Makurat-KasprolewiczBalbina Makurat-Kasprolewicz
Balbina Makurat-Kasprolewicz
MWMarcin Wekwejt
Marcin Wekwejt
Luca PezzatoLuca Pezzato
Luca Pezzato
Jolanta KrupaJolanta Krupa
Jolanta Krupa
SZSławomir Zimowski
Sławomir Zimowski
AOAgnieszka Ossowska
Agnieszka Ossowska

30 June 2020 in Tribologia
Verified
Journal Article
Closed access
Jolanta KrupaJolanta Krupa
Jolanta Krupa
GWGrzegorz Wiązania
Grzegorz Wiązania
SZSławomir Zimowski
Sławomir Zimowski
MKMarcin Kot
Marcin Kot
Fatigue cracking of thin hard anti-wear coatings occurs, among others, in the tribological contact of sliding friction pairs, in the top layers of cutting tools coatings, as well as in the surface of elements subjected to erosion processes. Coating fatigue wear is initiated as a result of cyclic interactions with micro-roughness of counterpart or other elements or particles that repeatedly impact the surface. The selection of appropriate coatings can increase the durability of machine components that are subjected to fatigue impact loads. The paper presents the results of tests on micro-impact fatigue wear of elements covered with single TiN and DLC coatings, as well as multi-layer (Ti/TiN)×8 type. Fatigue tests were carried out using the micro-impact method by cyclic impact of the surface of the coating with a diamond ball. The experiments were performed using a special laboratory stand. The correlation between fatigue life of coatings and their micromechanical properties such as Young's modulus and hardness were also examined. The hardness and Young's modulus were determined by an instrumented indentation method. The test results proved that the (Ti/TiN)×8 multilayer coating demonstrates wear 1.4 times smaller than the sample with the TiN coating and 1.2 than the sample with the DLC coating.

11 July 2024 in Materials
Verified
Journal Article
Open access
PDF file
Maciej JedlińskiMaciej Jedliński
Maciej Jedliński
Jolanta KrupaJolanta Krupa
Jolanta Krupa
Joanna Janiszewska-OlszowskaJoanna Janiszewska-Olszowska
Joanna Janiszewska-Olszowska
Background: Despite the large variety of retainer wires available, no studies could be found comparing the micromechanical properties and surface roughness of different retainer wires. Such characteristics affect the survival of the fixed retainer in terms of both fracture resistance and resistance to debonding from the tooth. Therefore, the aim of the present study was to examine and compare those characteristics in popular retainer wires. Methods: six different popular orthodontic retainer wires were subjected to instrumental indentation based on the Oliver and Pharr method. The geometric surface structure was analysed using a non-contact profilometer. Results: stainless steel wires had a higher hardness and a higher elastic modulus compared to titanium wires and white gold chain. The titanium wire and the white gold chain showed much more roughness than other wires. Conclusions: stainless steel wires are the most resistant, considering both the shape retention capacity and the ability to resist abrasive wear. The titanium wire showed the lowest hardness and, thus, the highest susceptibility to deformation. Bond-a-braid, Retainium and Orthoflex white gold are more resistant to fracture than other steel wires. Titanium wire and chain retainer wires have more roughness, which is a great advantage in terms of mechanical adhesion to composite materials.

24 August 2026 in Materials
Verified
Journal Article
Open access
PDF file
Jolanta KrupaJolanta Krupa
Jolanta Krupa
JBJędrzej Blaut
Jędrzej Blaut
MWMariusz Warzecha
Mariusz Warzecha
MKMateusz Kozioł
Mateusz Kozioł
ŁBŁukasz Breńkacz
Łukasz Breńkacz
This paper presents the results of experimental studies on the mechanical and tribological properties of samples produced using the fused filament fabrication method. These studies aim to identify a potential material for a water-lubricated sliding bearing that will be manufactured using 3D printing. Printed specimens fabricated from four different materials were analyzed for surface profile, mechanical properties via the instrumented indentation method, and tribological behavior using a pin-on-disc setup. Although increased hardness is generally associated with improved resistance to wear, the material that exhibited the lowest wear in the pin-on-disc tests was characterized by the lowest hardness among all investigated materials. The findings suggest that other aspects, including wear mechanisms, wear products, and tribolayer development, may also exert a substantial influence.

31 May 2022 in Tribologia
Verified
Journal Article
Closed access
Jolanta KrupaJolanta Krupa
Jolanta Krupa
SZSławomir Zimowski
Sławomir Zimowski
Fatigue tests are commonly used to define the mechanical properties of materials intended for responsible components operating in various conditions. The fatigue strength of monolithic materials is most often determined during bending, tensile, compression, or torsion tests. The growing area of thin, hard coatings application forced the researchers to extend the fatigue tests to the coating-substrate systems. Since the behaviour of complex, modern materials are not subject to general rules, it is necessary to conduct investigation and analyses and generalise the results of these tests for given groups of materials. In this article, microimpact fatigue tests were performed to analyse the behaviour of single- and double-layer chromium and chromium nitride coatings. The microhardness and elastic modulus obtained by an indentation method were used to determine the influence of mechanical properties of the coatings on their fatigue wear. After the fatigue tests, the deformation of the coating/substrate system was examined, taking into account the geometry of the craters, and the forms of coating wear caused mainly by cracking were analysed.