Bastien Van Esbeen

Mr. Bastien Van Esbeen

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BEBastien Van Esbeen
Bastien Van Esbeen
CFCyrille Finet
Cyrille Finet
RVRobin Vandebrouck
Robin Vandebrouck
DKDamien Kinet
Damien Kinet
KBKevin Boelen
Kevin Boelen
Christophe CaucheteurChristophe Caucheteur
Christophe Caucheteur
There is today ample evidence that fiber Bragg gratings (FBGs) distributed along a railway track can provide robust axle counting and bring numerous assets compared to competing technologies in this practical environment. This work brings two relevant originalities with respect to the state-of-the-art solutions. First, a study of the strain distribution in the rail cross-section is performed to determine the sensitivity according to the charge and the position on the rail. Secondly, the technology is deployed along the rail track as a smart object where the sensor head is composed of four FBG wavelength-division-multiplexed in a single telecommunication-grade optical fiber and interrogated by a miniaturized read-out device. Two FBGs ensure the detection of the train direction and another two bring the required redundancy to reach a safety integrity level (SIL) 4. The read-out unit has been specifically developed for the application and contains a vertical-cavity surface-emitting laser (VCSEL) and a photodiode driven by a high-speed microprocessor unit that processes the data and communicates the useful information, i.e., the number of axles. On-field tests confirm that the proposed approach makes the installation process easier while it democratizes the technology.

24 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BEBastien Van Esbeen
Bastien Van Esbeen
VMValentin Manto
Valentin Manto
DKDamien Kinet
Damien Kinet
CGcorentin guyot
corentin guyot
Christophe CaucheteurChristophe Caucheteur
Christophe Caucheteur
This article presents the findings of an experimental study conducted on a vertical axis wind turbine (VAWT) tower instrumented with cascaded fiber Bragg grating (FBG) sensors to detect bending deformations. Structural health monitoring (SHM) is an essential need in the industry to reduce costs and maintenance time, and to prevent machine failures. First, FBG strain sensors were glued vertically along the tower to investigate the sensors behavior as a function of their height. The maximum signal-to-noise ratio is obtained when FBGs are placed at the tower base. Then, four packages were installed inside the tower, at the base, according to four cardinal directions. Each package contains an FBG strain sensor, and an extra temperature FBG for discrimination. The use of easy-to-deploy packages is a must for industrial installations. Afterwards, by using power spectral density (PSD) on the strain signals, three sources of tower oscillations are discovered: wind force, structure unbalance, and 1st tower mode resonance, each with its intrinsic frequency. Wind force and structure unbalance cause mechanical stresses at a frequency proportional to the wind turbine rotational speed, while the 1st tower mode frequency depends only on the machine geometry, regardless of the rotational speed. This study also analyzes the deformation amplitude for different rotational rates within the VAWT operational range (10–35 rpm). The resonance amplitude depends on the proximity of the rotational rate to the resonant frequency (22 rpm) and the duration at that rate. For structure unbalance, the oscillation amplitude increases with the rotational rate, due to the centrifugal effect. It is supposed that wind force deformation amplitude naturally depends on wind speed, which is unpredictable at a given precise time. The results of our experimental observations are very valuable for both the wind turbine manufacturer and owner.

28 December 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BEBastien Van Esbeen
Bastien Van Esbeen
DKDamien Kinet
Damien Kinet
CGCorentin Guyot
Corentin Guyot
ADAnnick Depré
Annick Depré
RKRik Knoppers
Rik Knoppers
Christophe CaucheteurChristophe Caucheteur
Christophe Caucheteur
This paper describes the creation and characterization of a smart elastic fabric strip that incorporates pre-strained fiber Bragg grating (FBG) sensors. The fabric strip is 700 mm long and 60 mm wide, and a standard single-mode optical fiber with four cascaded and wavelength-division-multiplexed gratings is sewn onto the strip. Each FBG sensor is affixed to a specifically-designed 3D-printed pad in a pre-strained manner, which permits the detection of both FBG traction and compression. Among three configurations, the design of the pad has been chosen following tensile tests. The sensitivity of the elastic fabric strip was measured, and it is found that there is a Bragg wavelength deviation of 12.2 pm per mm of textile elongation and 11.7 pm per mm in release. Validation tests are conducted to demonstrate the system sensitivity to compression: indeed, a negative Bragg wavelength shift compared to the rest position can be observed. Afterwards, ten traction cycles are applied to the fabric strip to validate its ability to repeat measurements in a dynamic setting. In stretched position, the standard deviation of the Bragg wavelength shifts from all the cycles is 2.46 pm. Similarly, in the rest position, the standard deviation is 0.60 pm. Finally, tests are performed in the context of backbone monitoring and results are analyzed for four backbone positions. These experiments pave the way to the use of the smart elastic band for the dynamic measurement of the backbone position of a patient.

24 December 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VTVictor Tocanne
Victor Tocanne
BEBastien Van Esbeen
Bastien Van Esbeen
DKDamien Kinet
Damien Kinet
CGCorentin Guyot
Corentin Guyot
CCChristophe Caucheteur
Christophe Caucheteur
In this paper, we report that a uniform fiber Bragg grating (FBG), interrogated with broadband light, can be used to reliably measure transverse force through the analysis of its unpolarized reflected amplitude spectrum. Unlike conventional FBG-based transverse force sensors, which typically rely on birefringence-induced spectral splitting or polarization-resolved interrogation schemes, our approach leverages the full spectral shape of the reflected signal, recorded with standard illumination. Two types of measurement devices are used for the readout process: (i) a broadband light source combined with an optical spectrum analyzer, and (ii) a spectrometer-based FBG interrogator. Both approaches yield similar performance in controlled conditions, confirming the robustness of the FBG interrogator, which is the only configuration suitable for deployment in the field. By training a model with hundreds of experimental spectra measured for calibrated transverse force values between 0 and 70 N, we achieve highly accurate and robust prediction of the applied transverse force, with a mean absolute error of 2.80 N for the multilayer perceptron (MLP) and 0.44 N for the gradient boosting (XGBoost) model. This data-driven method removes the need for polarization control or complex grating structures, and opens a new pathway towards simple, cost-effective, and highly sensitive transverse force sensing.

1 January 2023
Verified
Conference Paper
Closed access
PDF file
BEBastien Van Esbeen
Bastien Van Esbeen
VMValentin Manto
Valentin Manto
DKDamien Kinet
Damien Kinet
CCChristophe Caucheteur
Christophe Caucheteur
This paper presents experimental results of FBG sensors used for SHM of a vertical axis wind turbine tower. Thanks to power spectral density computations, three deformation types are detected, each characterized by a specific frequency.

25 June 2025 in Optics Letters
Verified
Journal Article
Closed access
BEBastien Van Esbeen
Bastien Van Esbeen
CCChun-Wei Chen
Chun-Wei Chen
TBTommy Boilard
Tommy Boilard
MBMartin Bernier
Martin Bernier
Christophe CaucheteurChristophe Caucheteur
Christophe Caucheteur
MDMichel J. F. Digonnet
Michel J. F. Digonnet
For many medical and safety applications, it is important to develop fiber sensors that can detect very low doses of gamma radiation (mGy) with integration times of 1 s or shorter. Here, we describe a sensor based on a new calorimetric technique that we believe is one of the most sensitive and compact reported to date. The fiber subjected to irradiation has a silica core doped with Ce-doped lutetium aluminum garnet nanocrystals selected to achieve a strong radiation-induced absorption (RIA). Light launched in the irradiated fiber is absorbed by RIA, the fiber heats up, and the temperature change is measured with a slow-light fiber Bragg grating (FBG) placed in physical contact with it. Thanks to the doped fiber’s large RIA, and the excellent resolution (mK/√Hz) and low drift (a few mK/min) of the slow-light sensor, with 1.2 W of excitation power at 1040 nm, this sensor has a very low detection limit of ∼6 mGy/√Hz. Thanks to the use of a short FBG (7 mm), it is also extremely small. With straightforward improvements, the detection limit can be reduced to sub-mGy/√Hz. For in situ measurements, this technique can also be easily extended to use the slow-light FBG itself as the radiation sensor.