Athanasios Batagiannis

Dr. Athanasios Batagiannis

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2010 in Current Opinion in Solid State and Materials Science
Verified
Journal Article
Closed access
ABAthanasios Batagiannis
Athanasios Batagiannis
MWMichael Wübbenhorst
Michael Wübbenhorst
JHJürg Hulliger
Jürg Hulliger

4 February 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Konstantinos George KalkanisKonstantinos George Kalkanis
Konstantinos George Kalkanis
Kyriaki KISKIRAKyriaki KISKIRA
Kyriaki KISKIRA
Panagiotis PapageorgasPanagiotis Papageorgas
Panagiotis Papageorgas
SKStavros D. Kaminaris
Stavros D. Kaminaris
Dimitrios D. PiromalisDimitrios D. Piromalis
Dimitrios D. Piromalis
ABAthanasios Batagiannis
Athanasios Batagiannis
Nowadays, there is a market need that is pushing manufacturers to support more sustainable product designs regardless of any crisis. Two important lessons that society inferred from the COVID-19 pandemic are that the industry needs an improved collaboration efficiency that can handle such emergencies and improve its resource conservation to avoid having shortages. Additive manufacturing technologies use 3D object scanners to direct hardware to deposit material, layer upon layer, in precise geometric shapes, and are positioned to provide a disruptive transformation in how products are designed and manufactured. They can provide for the planet in fighting against crisis from a materials and applications perspective. In this context, the optimization and production of emergency ventilators in health systems were investigated with plans for 3D printing received from the University of Illinois Urbana–Champaign. An evaluation of the printability of CAD files and a partial redesign to limit dimensional variability, acceptable surface finish, and a more efficient printing process were performed. Six parts of the design were redesigned to make printing easier, faster, and less expensive. In the case of the O2 inlet attachment, the necessary supports were difficult to remove due to the part’s geometry, leading to redesign. The modulator top and bottom part, the patient tee, the manometer body, and the pop-off valve cap were also redesigned in order to avoid dimensional variability and possible rough surfaces. Metallic and thermoplastic composite ventilators were produced and then tested in real operating conditions, such as in a hospital setting with a realistic oxygen supply. The preliminary findings are promising compared to the initial design, both in terms of construction quality and performance such as exhalation rate adjustment and emergency valve operation. Also, a combination of manufacturing technologies was evaluated. The modifications allowed optimal casting (injection molding) of the parts and therefore faster production, instead of printing each part, when high output is required.

17 December 2009 in CrystEngComm
Verified
Journal Article
Closed access
PDF file
GLGaël Labat
Gaël Labat
NBNorwid-Rasmus Behrnd
Norwid-Rasmus Behrnd
GCGaëtan Couderc
Gaëtan Couderc
MBMichel Bonin
Michel Bonin
JTJulius Tsuwi
Julius Tsuwi
JHJürg Hulliger
Jürg Hulliger
4-Iodo-4′-nitrobiphenyl (INBP), a typical nonlinear optical molecule, features three polymorphs: Fdd2 as known before and two new forms, P2/c and P2. Monopolar crystals of the Fdd2 structure express a polar morphology and allowed an absolute structure determination. Iodo substituents cover the (001) and related faces. A negative pyroelectric coefficient was observed. The P2/c form was obtained from sublimation. Heating INBP (Fdd2) in the range of 150 to 180 °C ended in a second polar form (P2). DSC and dielectric measurements allowed us to assume a diffuse type of phase change from Fdd2 into P2. Lattice energy calculations for Fdd2 and P2/c yielded very similar energies. The twinning state observed for crystals not expressing polar symmetry is explained as a 50 : 50 % intergrowth of Fdd2 and P2/c. Periodic fragments allowed the close packing mode of all three polymorphs to be understood. A Hirshfeld surface analysis makes evident that apart from a strong linear synthon (I⋯NO2) other interactions in all three forms are very similar.

4 November 2022 in Magnetochemistry
Verified
Journal Article
Open access
PDF file
GBGeorgios Banis
Georgios Banis
Maria SavvidouMaria Savvidou
Maria Savvidou
Antonios GeorgasAntonios Georgas
Antonios Georgas
ABAthanasios Batagiannis
Athanasios Batagiannis
FKFragiskos N. Kolisis
Fragiskos N. Kolisis
Evangelos HristoforouEvangelos Hristoforou
Evangelos Hristoforou
Electroporation is a technique applied both in biomedical and biotechnological fields which uses a high-voltage electric current to temporarily destabilize the plasma membrane of living cells, permitting the introduction of small molecules as well as nucleic acids into the cytosol. Besides viral and chemical transfections, this method is a common way to manipulate living cells. However, the majority of electroporation machines available on the market can only work using batch-based cuvettes treating only a few micrograms of cells. To transform cells in the order of several grams in the quickest possible way, it is necessary to use a continuous-flow method. In this work, we present the design, electric and fluid dynamics simulations, construction and testing of a flow cuvette that can adapt to standard electroporator systems. The flow cuvette connected with a peristaltic pump was able to successfully electroporate 20 mL of medium containing microalgae cells in less than 5 min. Microalgae Scenedesmus almeriensis cells were transfected with a fluorescent siRNA oligo as well as magnetically transformed by introducing magnetic nanoparticles in their cytoplasm. The flow cuvette presented here offers a valid tool for the high-throughput transformation/transfection/transfer of both prokaryotic and eukaryotic organisms, especially suitable for bioreactor cultivation and other industrial biotechnological contexts.

31 October 2025 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
GBGeorgios Banis
Georgios Banis
CKCharoula Kousiatza
Charoula Kousiatza
MSMaria Sarkiri
Maria Sarkiri
KTKostas Touloupas
Kostas Touloupas
ASAlexis Spiliotopoulos
Alexis Spiliotopoulos
ABAthanasios Batagiannis
Athanasios Batagiannis
Purpose: Total hip arthroplasty is among the most successful orthopedic procedures; however, approximately 10%–20% of patients require revision surgery within 15–20 years. Potential failure mechanisms at the bone–implant interface include stress shielding and excessive micromotion. This experimental work aims at examining the optimal ratio of femur length and stem length with respect to primary stability and stress shielding effect, employing a validated finite element analysis. Methods: One hundred human femora were reconstructed from computed tomography (CT) scans, and for each femur, 13 personalized cementless stems were designed with varying lengths (70–130 mm, in 5 mm increments), resulting in 1300 finite element models. Each model was analyzed under standardized joint and muscle loading conditions. The model was validated experimentally after cadaveric implantation with digital image correlation (DIC) under static loading. Primary outcomes included micromotion at the bone–implant interface and proximal stress shielding. Optimal stem length was determined as the ratio of stem‐to‐femur length that minimized the combined normalized scores of micromotion and stress shielding. The effect of stem‐to‐femur length ratio was analysed with linear regression. Results: The analysis revealed a correlation between femoral length and stem length. Longer stems provided better initial stability and reduced micromotion. On the other hand, shorter stems demonstrated less proximal stress shielding and a better stress distribution resembling that of the intact femur. The optimal stem length was found to be 18.5% ± 2.7% (mean ± SD) of the femur length in terms of the mean of calculated micromotions and stress shielding, indicating that personalized stem length selection can enhance the bone–implant osseointegration. Conclusion: The selection of a stem length that corresponds proportionally to femoral length can improve primary stability and stress shielding upon implantation, highlighting the importance of enhancing initial fixation in order to extend the lifespan of hip replacements. Level of Evidence: N/A.

2 August 2008 in Journal of Mathematical Chemistry
Verified
Journal Article
Closed access
PDF file
ABAthanasios Batagiannis
Athanasios Batagiannis
TWThomas Wüst
Thomas Wüst
JHJürg Hulliger
Jürg Hulliger