Brian De La Franier

Dr. Brian De La Franier

University of Toronto, Department of Chemistry
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

26 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SSSandro Spagnolo
Sandro Spagnolo
Brian De La FranierBrian De La Franier
Brian De La Franier
KDKatharina Davoudian
Katharina Davoudian
Tibor HianikTibor Hianik
Tibor Hianik
Michael ThompsonMichael Thompson
Michael Thompson
Milk is a significant foodstuff around the world, being produced and consumed in large quantities. The safe consumption of milk requires that the liquid has an acceptably low level of microbial contamination and has not been subjected to spoiling. Bacterial safety limits in milk vary by country but are typically in the thousands per mL of sample. To rapidly determine if samples contain an unsafe level of bacteria, an aptamer-based sensor specific to Escherichia coli bacteria was developed. The sensor is based on an ultra-high frequency electromagnetic piezoelectric acoustic sensor device (EMPAS), with the aptamer being covalently bound to the sensor surface by the anti-fouling linker, MEG-Cl. The sensor is capable of the selective measurement of E. coli in PBS and in cow’s milk samples down to limits of detection of 35 and 8 CFU/mL, respectively, which is well below the safe limits for commercial milk products. This sensing system shows great promise for the milk industry for the purpose of rapid verification of product safety.

14 February 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
Brian De La FranierBrian De La Franier
Brian De La Franier
Michael ThompsonMichael Thompson
Michael Thompson
Lysophosphatidic acid (LPA) is present during the medical condition of ovarian cancer at all stages of the disease, and, therefore possesses considerable potential as a biomarker for screening its presence in female patients. Unfortunately, there is currently no clinically employable assay for this biomarker. In the present work, we introduce a test based on the duel protein system of actin and gelsolin that could allow the quantitative measurement of LPA in serum samples in a biosensing format. In order to evaluate this possibility, actin protein was dye-modified and complexed with gelsolin protein, followed by surface deposition onto silica nanoparticles. This solid-phase system was exposed to serum samples containing various concentrations of LPA and analyzed by fluorescence microscopy. Measurements conducted for the LPA-containing serum samples were higher after exposure to the developed test than samples without LPA. Early results suggest a limit of detection of 5 μM LPA in serum. The eventual goal is to employ the chemistry described here in a biosensor configuration for the large population-scale, rapid screening of women for the potential occurrence of ovarian cancer.

1 April 2021 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
Brian De La FranierBrian De La Franier
Brian De La Franier
DADalal Asker
Dalal Asker
DBDesmond van Den Berg
Desmond van Den Berg
BHBenjamin Hatton
Benjamin Hatton
Michael ThompsonMichael Thompson
Michael Thompson

1 August 2017 in Applied Surface Science
Verified
Journal Article
Closed access
Brian De La FranierBrian De La Franier
Brian De La Franier
AJAlexander Jankowski
Alexander Jankowski
MTMichael Thompson
Michael Thompson

3 March 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
SSSandro Spagnolo
Sandro Spagnolo
Brian De La FranierBrian De La Franier
Brian De La Franier
Tibor HianikTibor Hianik
Tibor Hianik
Michael ThompsonMichael Thompson
Michael Thompson
This paper describes the anti-fouling capability of the novel monolayer-forming surface linker 3-(3-(trichlorosilylpropyloxy) propanoyl chloride (MEG-Cl). This compound was successfully attached to quartz crystal surfaces which are employed in an electromagnetic piezoelectric acoustic sensor (EMPAS) configuration. The MEG-Cl coated surface was both employed with Ni-NTA for the binding of recombinant proteins and for the tandem property of the avoidance of fouling from serum and milk. The MEG-Cl coated surfaces were found to provide a large degree of anti-fouling on the EMPAS device, and were comparable to previously studied MEG-OH surfaces. Importantly, the monolayer continued to provide anti-fouling capability to the biosensor following extension with Ni-NTA in place. Accordingly, this surface linker provides an attractive system for use in biosensor technology in terms of both its anti-fouling and linking properties.