Benedicte Schelde-Olesen

Dr. Benedicte Schelde-Olesen

Department of Surgery, Odense University Hospital, Odense, Syddanmark, Denmark
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2023 in Techniques in Coloproctology
Verified
Journal Article
Open access
PDF file
BSBenedicte Schelde-Olesen
Benedicte Schelde-Olesen
TBT. Bjørsum-Meyer
T. Bjørsum-Meyer
AKA. Koulaouzidis
A. Koulaouzidis
MBM. M. Buijs
M. M. Buijs
JHJ. Herp
J. Herp
UDU. Deding
U. Deding
Purpose: When an optical colonoscopy is carried out, Scope Guide can assist the endoscopist in determining the localization. In colon capsule endoscopy (CCE), this support is not available. To our knowledge, the interobserver agreement on landmark identification has never been studied. This study aims to investigate the interobserver agreement on landmark identification in CCE. Methods: An interobserver study was carried out comparing the landmark identification (the ileocecal valve, hepatic flexure, splenic flexure, and anus) in CCE investigations between an external private contractor and three in-house CCE readers with different levels of experience. All CCE investigations analyzed in this study were carried out as a part of the Danish screening program for colorectal cancer. Patients were between 50 and 74 years old with a positive fecal immunochemical test (FIT). A random sample of 20 CCE investigations was taken from the total sample of more than 800 videos. Results: Overall interobserver agreement on all landmarks was 51%. Interobserver agreement on the first cecal image (ileocecal valve), hepatic flexure, splenic flexure, and last rectal image (anus) was 72%, 29%, 22%, and 83%, respectively. The overall interobserver agreement, including only examinations with adequate bowel preparation (n = 16), was 54%, and for individual landmarks, 73%, 32%, 24%, and 85%. Conclusion: Overall interobserver agreement on all four landmarks from CCE was poor. Measures are needed to improve landmark identification in CCE investigations. Artificial intelligence could be a possible solution to this problem.

15 November 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
UDUlrik Deding
Ulrik Deding
SJSofie Sajan Jensen
Sofie Sajan Jensen
BSBenedicte Schelde-Olesen
Benedicte Schelde-Olesen
LKLasse Kaalby
Lasse Kaalby
TBThomas Bjørsum-Meyer
Thomas Bjørsum-Meyer
Anastasios KoulaouzidisAnastasios Koulaouzidis
Anastasios Koulaouzidis
Completing colon capsule endoscopy (CCE) investigations rely on successful transit and acceptable bowel preparation quality. We investigated the effect of adding castor oil to the CCE bowel preparation regimen on the completion rate using a meta-analysis of existing literature. We conducted a systematic literature search in PubMed, Web of Science, and Embase. Included studies underwent quality assessment, and data for meta-analysis were extracted. Pooled estimates for excretion rate and acceptable bowel preparation rate were calculated. We identified 72 studies matching our search criteria, and six were included in the meta-analysis. Three of the studies had control groups, although two used historical cohorts. The pooled excretion rate (92%) was significantly higher in patients who received castor oil than in those who did not (73%). No significant difference in acceptable colonic cleanliness was observed. Castor oil has been used in a few studies as a booster for CCE. This meta-analysis shows the potential for this medication to improve excretion rates, and castor oil could be actively considered in conjunction with other emerging laxative regimens in CCE. Still, prospective randomized trials with appropriate control groups should be conducted before any conclusions can be drawn. Prospero ID: CRD42022338939.

1 January 2024 in Therapeutic Advances in Gastroenterology
Verified
Journal Article
Open access
BSBenedicte Schelde-Olesen
Benedicte Schelde-Olesen
Anastasios KoulaouzidisAnastasios Koulaouzidis
Anastasios Koulaouzidis
UDUlrik Deding
Ulrik Deding
Ervin TothErvin Toth
Ervin Toth
KDKonstantinos John Dabos
Konstantinos John Dabos
TBThomas Bjørsum-Meyer
Thomas Bjørsum-Meyer
Background: The diagnostic accuracy of colon capsule endoscopy (CCE) depends on a well-cleansed bowel. Evaluating the cleansing quality can be difficult with a substantial interobserver variation. Objectives: Our primary aim was to establish a standard of agreement for bowel cleansing in CCE based on evaluations by expert readers. Then, we aimed to investigate the interobserver agreement on bowel cleansing. Design: We conducted an interobserver agreement study on bowel cleansing quality. Methods: Readers with different experience levels in CCE and colonoscopy evaluated bowel cleansing quality on the Leighton–Rex scale and Colon Capsule CLEansing Assessment and Report (CC-CLEAR), respectively. All evaluations were reported on an image level. A total of 24 readers rated 500 images on each scale. Results: An expert opinion-based agreement standard could be set for poor and excellent cleansing but not for the spectrum in between, as the experts agreed on only a limited number of images representing fair and good cleansing. The overall interobserver agreement on the Leighton–Rex full scale was good (intraclass correlation coefficient (ICC) 0.84, 95% CI (0.82–0.85)) and remained good when stratified by experience level. On the full CC-CLEAR scale, the overall agreement was moderate (ICC 0.62, 95% CI (0.59–0.65)) and remained so when stratified by experience level. Conclusion: The interobserver agreement was good for the Leighton–Rex scale and moderate for CC-CLEAR, irrespective of the reader’s experience level. It was not possible to establish an expert-opinion standard of agreement for cleansing quality in CCE images. Dedicated training in using the scales may improve agreement and enable future algorithm calibration for artificial intelligence supported cleansing evaluation. Trial registration: All included images were derived from the CAREforCOLON 2015 trial (Registered with The Regional Health Research Ethics Committee (Registration number: S-20190100), the Danish data protection agency (Ref. 19/29858), and ClinicalTrials.gov (registration number: NCT04049357)).

21 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
BSBenedicte Schelde-Olesen
Benedicte Schelde-Olesen
ANArtur Nemeth
Artur Nemeth
GJGabriele Wurm Johansson
Gabriele Wurm Johansson
UDUlrik Deding
Ulrik Deding
TBThomas Bjørsum-Meyer
Thomas Bjørsum-Meyer
Ervin TothErvin Toth
Ervin Toth
Colon capsule endoscopy (CCE) is a promising modality for colonic investigations, but completion rates (CR) and adequate cleansing rates (ACR) must be improved to meet established standards for optical colonoscopy. Improvements should be made with patient acceptability in mind. We aimed to compare a very low-volume polyethylene glycol (PEG) laxative to a conventional high-volume laxative. We carried out a single-center retrospective comparative cohort study including patients referred for CCE. One hundred and sixty-six patients were included in the final analysis, with eighty-three patients in each group. We found a CR and ACR of 77% and 67% in the high-volume group and 72% and 75% in the very low-volume group, respectively. In the high-volume group, 54% had complete transit and adequate cleansing, whereas this was the case for 63% in the very low-volume group. No statistically significant difference in CR, ACR, or a combination of the two was found. A very low-volume bowel preparation regimen was non-inferior to a high-volume regimen before CCE in terms of CR and ACR.

6 October 2023 in BMJ Open
Verified
Journal Article
Open access
PDF file
BSBenedicte Schelde-Olesen
Benedicte Schelde-Olesen
LKLasse Kaalby
Lasse Kaalby
UDUlrik Deding
Ulrik Deding
MTMaja M I Thygesen
Maja M I Thygesen
PAPer Vadgaard Andersen
Per Vadgaard Andersen
TBThomas Bjørsum-Meyer
Thomas Bjørsum-Meyer
Introduction Follow-up after an episode of colonic diverticulitis is a common indication for colonoscopy, even though studies have shown a low risk of positive findings in this population. Our objective is to investigate colon capsule endoscopy (CCE) as a follow-up examination in patients with colonic diverticulitis compared with colonoscopy, particularly regarding patient satisfaction and clinical performance. Methods and analysis We will conduct a single-centre prospective randomised controlled trial. Patients seen at Odense University Hospital with acute diverticulitis confirmed by CT will be included and randomised to either follow-up by colonoscopy or CCE. Detection of suspected cancer, more than two polyps or any number of polyps larger than 9 mm in CCE will generate an invitation to a diagnostic colonoscopy for biopsies or polyp removal. We will compare colonoscopy and CCE regarding patient satisfaction and tolerance, the number of complete examinations, the number of patients referred to a subsequent colonoscopy after CCE and the prevalence of diverticula, polyps, cancers and other abnormal findings. Ethics and dissemination Informed consent will be obtained from all participants before randomisation. The study was approved by the regional ethics committee (ref. S-20210127) and the Danish Data Protection Agency (ref. 22/43235). After completion of the trial, we plan to publish two articles in high-impact journals. One article on both primary and secondary outcomes. Trial registration number NCT05700981.

29 August 2025 in Cancers
Verified
Journal Article
Open access
PDF file
ILIan Io Lei
Ian Io Lei
DGDaniel R. Gaya
Daniel R. Gaya
ARAlexander Ross Robertson
Alexander Ross Robertson
BSBenedicte Schelde-Olesen
Benedicte Schelde-Olesen
AMAlice Mapiye
Alice Mapiye
RARamesh Arasaradnam
Ramesh Arasaradnam
Background: Colon capsule endoscopy (CCE) has seen increased adoption since the COVID-19 pandemic, offering a non-invasive alternative for lower gastrointestinal investigations. However, inadequate bowel preparation remains a key limitation, often leading to higher conversion rates to colonoscopy. Manual assessment of bowel cleanliness is inherently subjective and marked by high interobserver variability. Recent advances in artificial intelligence (AI) have enabled automated cleansing scores that not only standardise assessment and reduce variability but also align with the emerging semi-automated AI reading workflow, which highlights only clinically significant frames. As full video review becomes less routine, reliable, and consistent, cleansing evaluation is essential, positioning bowel preparation AI as a critical enabler of diagnostic accuracy and scalable CCE deployment. Objective: This CESCAIL sub-study aimed to (1) evaluate interobserver agreement in CCE bowel cleansing assessment using two established scoring systems, and (2) determine the impact of AI-assisted scoring, specifically a TransUNet-based segmentation model with a custom Patch Loss function, on both interobserver and intraobserver agreement compared to manual assessment. Methods: As part of the CESCAIL study, twenty-five CCE videos were randomly selected from 673 participants. Nine readers with varying CCE experience scored bowel cleanliness using the Leighton–Rex and CC-CLEAR scales. After a minimum 8-week washout, the same readers reassessed the videos using AI-assisted CC-CLEAR scores. Interobserver variability was evaluated using bootstrapped intraclass correlation coefficients (ICC) and Fleiss’ Kappa; intraobserver variability was assessed with weighted Cohen’s Kappa, paired t-tests, and Two One-Sided Tests (TOSTs). Results: Leighton–Rex showed poor to fair agreement (Fleiss = 0.14; ICC = 0.55), while CC-CLEAR demonstrated fair to excellent agreement (Fleiss = 0.27; ICC = 0.90). AI-assisted CC-CLEAR achieved only moderate agreement overall (Fleiss = 0.27; ICC = 0.69), with weaker performance among less experienced readers (Fleiss = 0.15; ICC = 0.56). Intraobserver agreement was excellent (ICC > 0.75) for experienced readers but variable in others (ICC 0.03–0.80). AI-assisted scores were significantly lower than manual reads by 1.46 points (p < 0.001), potentially increasing conversion to colonoscopy. Conclusions: AI-assisted scoring did not improve interobserver agreement and may even reduce consistency amongst less experienced readers. The maintained agreement observed in experienced readers highlights its current value in experienced hands only. Further refinement, including spatial analysis integration, is needed for robust overall AI implementation in CCE.