Benita Johannsen

Ms. Benita Johannsen

Hahn-Schickard, Freiburg im Breisgau, Baden-Württemberg, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
KMKonstantinos Mitsakakis
Konstantinos Mitsakakis
BJBenita Johannsen
Benita Johannsen
MSMara Specht
Mara Specht
JLJan Lüddecke
Jan Lüddecke
MRMarkus Rombach
Markus Rombach
KMKonstantinos Mitsakakis
Konstantinos Mitsakakis
Periodontitis and dental caries are two major bacterially induced, non-communicable diseases that cause the deterioration of oral health, with implications in patients’ general health. Early, precise diagnosis and personalized monitoring are essential for the efficient prevention and management of these diseases. Here, we present a disk-shaped microfluidic platform (OralDisk) compatible with chair-side use that enables analysis of non-invasively collected whole saliva samples and molecular-based detection of ten bacteria: seven periodontitis-associated (Aggregatibacter actinomycetemcomitans, Campylobacter rectus, Fusobacterium nucleatum, Prevotella intermedia, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola) and three caries-associated (oral Lactobacilli, Streptococcus mutans, Streptococcus sobrinus). Each OralDisk test required 400 µL of homogenized whole saliva. The automated workflow included bacterial DNA extraction, purification and hydrolysis probe real-time PCR detection of the target pathogens. All reagents were pre-stored within the disk and sample-to-answer processing took < 3 h using a compact, customized processing device. A technical feasibility study (25 OralDisks) was conducted using samples from healthy, periodontitis and caries patients. The comparison of the OralDisk with a lab-based reference method revealed a ~90% agreement amongst targets detected as positive and negative. This shows the OralDisk’s potential and suitability for inclusion in larger prospective implementation studies in dental care settings.

30 November 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
BJBenita Johannsen
Benita Johannsen
LMLara Müller
Lara Müller
DBDesirée Baumgartner
Desirée Baumgartner
LKLena Karkossa
Lena Karkossa
SFSusanna M. Früh
Susanna M. Früh
KMKonstantinos Mitsakakis
Konstantinos Mitsakakis
Saliva offers many advantages for point-of-care (PoC) diagnostic applications due to non-invasive, easy, and cost-effective methods of collection. However, the complex matrix with its non-Newtonian behavior and high viscosity poses handling challenges. Several tedious and long pre-analytic steps, incompatible with PoC use, are required to liquefy and homogenize saliva samples before protein analysis can be performed. We apply magnet-beating to reduce hands-on time and to simplify sample preparation. A magnet in a chamber containing the whole saliva is actuated inside a centrifugal microfluidic cartridge by the interplay of centrifugal and magnetic forces. Rigorous mixing, which homogenizes the saliva sample, is then initiated. Consequently, fewer manual steps are required to introduce the whole saliva into the cartridge. After 4 min of magnet-beating, the processed sample can be used for protein analysis. The viscosity of whole saliva has been reduced from 10.4 to 2.3 mPa s. Immunoassay results after magnet-beating for three salivary periodontal markers (MMP-8, MMP-9, TIMP-1) showed a linear correlation with a slope of 0.99 when compared to results of reference method treated samples. Conclusively, magnet-beating has been shown to be a suitable method for the pre-analytic processing of whole saliva for fully automated PoC protein analysis.

14 November 2020 in Antibiotics
Verified
Journal Article
Open access
PDF file
Georgios BelibasakisGeorgios Belibasakis
Georgios Belibasakis
BLBodil K. Lund
Bodil K. Lund
CWCarina Krüger Weiner
Carina Krüger Weiner
BJBenita Johannsen
Benita Johannsen
DBDesirée Baumgartner
Desirée Baumgartner
KMKonstantinos Mitsakakis
Konstantinos Mitsakakis
Antibiotic resistance poses a global threat, which is being acknowledged at several levels, including research, clinical implementation, regulation, as well as by the World Health Organization. In the field of oral health, however, the issue of antibiotic resistances, as well as of accurate diagnosis, is underrepresented. Oral diseases in general were ranked third in terms of expenditures among the EU-28 member states in 2015. Yet, the diagnosis and patient management of oral infections, in particular, still depend primarily on empiric means. On the contrary, on the global scale, the field of medical infections has more readily adopted the integration of molecular-based systems in the diagnostic, patient management, and antibiotic stewardship workflows. In this perspective review, we emphasize the clinical significance of supporting in the future antibiotic resistance screening in dental practice with novel integrated and point-of-care operating tools that can greatly support the rapid, accurate, and efficient administration of oral antibiotics.

1 April 2021 in Analytica Chimica Acta
Verified
Journal Article
Open access
BJBenita Johannsen
Benita Johannsen
MKMichal Karpíšek
Michal Karpíšek
DBDesirée Baumgartner
Desirée Baumgartner
VKVanessa Klein
Vanessa Klein
Nagihan BostanciNagihan Bostanci
Nagihan Bostanci
KMKonstantinos Mitsakakis
Konstantinos Mitsakakis
We present a simple and fast one-step heterogeneous immunoassay, with performance characteristics that can enable easy and versatile adaptation to miniaturized, automated point-of-care systems. This novel analytical method uses magnetic and fluorescent beads as capture and detection agents respectively. Its main feature is the measurement of the fluorescent signal in the bound-free phase for (semi-)quantitative detection of analytes. Thus, no washing is required and the workflow consists only of sample and reagent supply, incubation, separation and detection. The immunoassay concept is demonstrated with C-reactive protein (CRP), a systemic inflammation marker. CRP in only 5 μL of undiluted serum was measured in the range 20-140 mg L-1 (includes clinically relevant cut-off values). The limit of detection (LOD) was 22.1 ± 6.3 mg L-1 (incubation 15 min). A CRP certified reference material was measured on five different days. Intra- and inter-assay coefficients of variation were 4.6 ± 1.9% and 5.6% respectively. To demonstrate the compatibility of the assay concept with additional matrices and concentration ranges, three oral inflammation markers, namely matrix metalloproteinases 8 and 9 (MMP-8, MMP-9) and tissue inhibitor of metalloproteinases 1 (TIMP-1), were measured in saliva in the ranges 0.47-30 ng mL-1 for MMP-8 and MMP-9, and 0.69-44 ng mL-1 for TIMP-1. LODs were 0.24 ng mL-1, 0.38 ng mL-1 and 0.39 ng mL-1 respectively (incubation 20 min). Multiplexing capacity of the assay concept was also shown with these markers. The demonstrated excellent reproducibility of the results, combined with the versatility and low complexity of the introduced immunoassay concept, make it an attractive candidate for applied analytical chemistry and automated point-of-care testing.

14 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
BJBenita Johannsen
Benita Johannsen
DBDesirée Baumgartner
Desirée Baumgartner
LKLena Karkossa
Lena Karkossa
NPNils Paust
Nils Paust
MKMichal Karpíšek
Michal Karpíšek
KMKonstantinos Mitsakakis
Konstantinos Mitsakakis
In this paper, we present the ImmunoDisk, a fully automated sample-to-answer centrifugal microfluidic cartridge, integrating a heterogeneous, wash-free, magnetic- and fluorescent bead-based immunoassay (bound-free phase detection immunoassay/BFPD-IA). The BFPD-IA allows the implementation of a simple fluidic structure, where the assay incubation, bead separation and detection are performed in the same chamber. The system was characterized using a C-reactive protein (CRP) competitive immunoassay. A parametric investigation on air drying of protein-coupled beads for pre-storage at room temperature is presented. The key parameters were buffer composition, drying temperature and duration. A protocol for drying two different types of protein-coupled beads with the same temperature and duration using different drying buffers is presented. The sample-to-answer workflow was demonstrated measuring CRP in 5 µL of human serum, without prior dilution, utilizing only one incubation step, in 20 min turnaround time, in the clinically relevant concentration range of 15–115 mg/L. A reproducibility assessment over three disk batches revealed an average signal coefficient of variation (CV) of 5.8 ± 1.3%. A CRP certified reference material was used for method verification with a concentration CV of 8.6%. Our results encourage future testing of the CRP-ImmunoDisk in clinical studies and its point-of-care implementation in many diagnostic applications.

18 December 2020 in Processes
Verified
Journal Article
Open access
PDF file
SHSebastian Hin
Sebastian Hin
DBDesirée Baumgartner
Desirée Baumgartner
MSMara Specht
Mara Specht
JLJan Lüddecke
Jan Lüddecke
EAEhsan Mahmodi Arjmand
Ehsan Mahmodi Arjmand
KMKonstantinos Mitsakakis
Konstantinos Mitsakakis
Effective mosquito monitoring relies on the accurate identification and characterization of the target population. Since this process requires specialist knowledge and equipment that is not widely available, automated field-deployable systems are highly desirable. We present a centrifugal microfluidic cartridge, the VectorDisk, which integrates TaqMan PCR assays in two feasibility studies, aiming to assess multiplexing capability, specificity, and reproducibility in detecting disk-integrated vector-related assays. In the first study, pools of 10 mosquitoes were used as samples. We tested 18 disks with 27 DNA and RNA assays each, using a combination of multiple microfluidic chambers and detection wavelengths (geometric and color multiplexing) to identify mosquito and malaria parasite species as well as insecticide resistance mechanisms. In the second study, purified nucleic acids served as samples to test arboviral and malaria infective mosquito assays. Nine disks were tested with 14 assays each. No false positive results were detected on any of the disks. The coefficient of variation in reproducibility tests was <10%. The modular nature of the platform, the easy adaptation of the primer/probe panels, the cold chain independence, the rapid (2–3 h) analysis, and the assay multiplexing capacity are key features, rendering the VectorDisk a potential candidate for automated vector analysis.