Biswarup Neogi

Dr. Biswarup Neogi

Associate Professor & Head, ECE Dept. JIS College of Engineering

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2023 in Education and Information Technologies
Verified
Journal Article
Closed access
PDF file
SGSourajit Ghosh
Sourajit Ghosh
SKSarwar Kamal
Sarwar Kamal
LCLinkon Chowdhury
Linkon Chowdhury
Biswarup NeogiBiswarup Neogi
Biswarup Neogi
Nilanjan DeyNilanjan Dey
Nilanjan Dey
R. Simon SherrattR. Simon Sherratt
R. Simon Sherratt

1 January 2012
Verified
Book Chapter
Closed access
PDF file
SGSoumya Ghosal
Soumya Ghosal
RDRajkumar Darbar
Rajkumar Darbar
Biswarup NeogiBiswarup Neogi
Biswarup Neogi
ADAchintya Das
Achintya Das
DTDewaki N. Tibarewala
Dewaki N. Tibarewala

19 October 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
SDSusmita Das
Susmita Das
Dalia NandiDalia Nandi
Dalia Nandi
Biswarup NeogiBiswarup Neogi
Biswarup Neogi
Biswajit SarkarBiswajit Sarkar
Biswajit Sarkar
System performance and efficiency depends on the stability criteria. The lower limb prosthetic model design requires some prerequisites such as hardware design functionality and compatibility of the building block materials. Effective implementation of mathematical model simulation symmetry towards the achievement of hardware design is the focus of the present work. Different postures of lower limb have been considered in this paper to be analyzed for artificial system design of lower limb movement. The generated polynomial equations of the sitting and standing positions of the normal limb are represented with overall system transfer function. The behavioral analysis of the lower limb model shows the nonlinear nature. The Euler-Lagrange method is utilized to describe the nonlinearity in the field of forward dynamics of the artificial system. The stability factor through phase portrait analysis is checked with respect to nonlinear system characteristics of the lower limb. The asymptotic stability has been achieved utilizing the most applicable Lyapunov method for nonlinear systems. The stability checking of the proposed artificial lower extremity is the newer approach needed to take decisions on output implementation in the system design.

18 January 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
Soumyendu BhattacharjeeSoumyendu Bhattacharjee
Soumyendu Bhattacharjee
Aishwarya BanerjeeAishwarya Banerjee
Aishwarya Banerjee
ARAmit Rakshit
Amit Rakshit
SBSwapan Bhattacharyya
Swapan Bhattacharyya
SCSwati Chowdhuri
Swati Chowdhuri
Biswarup NeogiBiswarup Neogi
Biswarup Neogi
In this paper, a complete non-linear symmetric oscillator model using the Hamiltonian approach has been developed and used to describe the cardiovascular conduction process’s dynamics, as the signal generated from the cardiovascular muscle is non-deterministic and random. Electrocardiogram (ECG) signal is a significant factor in the cardiovascular system as most of the medical diagnoses can be well understood by observing the ECG signal’s amplitude. A non-linear cardiovascular muscle model has been proposed in this study, where a modified vanderPol symmetric oscillator-based equation is used. Gone are the days whena non-linear system had been designed using the describing function technique. It is better to design a non-linear model using the Hamiltonian dynamical equation for its high accuracy and flexibility. Varying a non-linear spring constant using this type of approach is more comfortable than the traditional describing function technique. Not only that but different initial conditions can also be taken for experimental purposes. It never affects the overall modeling. The Hamiltonian approach provides the energy of an asymmetric oscillatory system of that cardiovascular conduction system. A non-linear symmetric oscillator was initially depicted by the non-linear mass-spring (two degrees of freedom) model. The motion of an uncertain non-linear cardiovascular system has been solved considering second-order approximation, which also demonstrates the possibility of introducing spatial dimensions. Finally, the model’s natural frequency expression has also been simulated and is composed of the previously published result.

15 June 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
SDSusmita Das
Susmita Das
Dalia NandiDalia Nandi
Dalia Nandi
Biswarup NeogiBiswarup Neogi
Biswarup Neogi
People with lower limb amputations struggle through difficulties during locomotion in their daily activities. People with transtibial amputations take support from prosthetic legs for systematic movement. During motion, they experience some mobility issues while using general prosthetic limbs regarding gait pattern. The design of a prosthetic-controlled lower limb with gait synchronization for physically disabled persons is the main goal of the present research work, which can provide an improved walking experience. The design and performance analysis of prosthetic lower limbs for people with transtibial amputations is performed in the present paper. The designed rehabilitation system shows synchronization between the normal and the prosthetic limbs achieved with gait coordination. The dynamics of the lower extremities in different postural activities are used for design purpose utilizing Euler–Lagrange motion theory. The artificial motion of the knee and the ankle joints function through the angular movement of the servo motors according to the movements of the rotary encoders placed on the sound limb joints. The range of motion of both the sound and prosthetic limbs are compared for different steps during a gait cycle. The prosthetic electronic system design of the artificial lower limb is able to show the gait style of human being with body kinesics. The nonlinear domain stability analysis of the designed prosthetic limb is presented through the Lyapunov method. A PIDF2 controller tuning process is implemented for the designed limb’s performance improvement. The designed prosthetic system is beneficial for people with unilateral transtibial amputations with a great societal impact.

21 September 2017 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
MNM S Nikitenko
M S Nikitenko
YMYu V Malakhov
Yu V Malakhov
Biswarup NeogiBiswarup Neogi
Biswarup Neogi
PCPritam Chakraborty
Pritam Chakraborty
DBDipesu Banerjee
Dipesu Banerjee
Proposal for the formulation of robotic complexes for steeply inclined coal seams as a basis of the supportive-enclosing walking module and power support with a controlled outlet for mining industry has been represented in this literature. In mining industry, the available resource base reserves and mineral deposits are concentrated deep down the earth crust leading towards a complicated geological condition i.e. abrupt ore bedding and steeply inclined strata with the high gas content and fire hazard of thick coal stratum, heading against an unfavorable and sometimes human labor life risk during subversive mining. Prevailing towards the development of effective robotic complexes based on the means of "unmanned technologies" for extraction of minerals from hard-to-reach deposits and make sure the safety of underground staff during sublevel mining technology.