Brie McMahan

Dr. Brie McMahan

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2024 in ACS Sustainable Resource Management
Verified
Journal Article
Closed access
RENJITH RAJAN PILLAIRENJITH RAJAN PILLAI
RENJITH RAJAN PILLAI
Brie McMahanBrie McMahan
Brie McMahan
LHLea Hebert
Lea Hebert
JOJonghwa Oh
Jonghwa Oh
Claudiu T LunguClaudiu T Lungu
Claudiu T Lungu
Vinoy ThomasVinoy Thomas
Vinoy Thomas

21 January 2026 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
Brie McMahanBrie McMahan
Brie McMahan
JOJonghwa Oh
Jonghwa Oh
RENJITH RAJAN PILLAIRENJITH RAJAN PILLAI
RENJITH RAJAN PILLAI
Vinoy ThomasVinoy Thomas
Vinoy Thomas
MAMary Appah
Mary Appah
CLClaudiu T. Lungu
Claudiu T. Lungu
Exposure to volatile organic compounds (VOCs) and particulate matter (PM) can cause adverse health effects such as pneumoconiosis-like symptoms, acute toxicity, and carcinogenesis. The present work aimed to test activated carbon fiber (ACF) as air-purifying media capable of dual-protection from both PM and VOC and evaluated the interaction between filtration efficiency (FE) and VOC retention by using breakthrough times. The first set of experiments exposed ACF 1200 (1,200 m2/g nominal surface area) to the VOC toluene at the permissible exposure limit (200 ppm) prior to introducing PM (NaCl, 200 mg/m3) into the airstream, and the second set of experiments introduced VOC into the airstream after PM exposure. Study findings suggest that ACF 1200 demonstrated a somewhat greater adsorption capacity (g/g) for toluene when PM was present, recording a value of 0.319 g/g, compared to 0.213 g/g in its absence. A slight decline in FE was observed in 1, and 4-layer combinations following initial exposure to VOCs. These findings suggest that the presence of PM may enhance ACFs' adsorption of VOCs; however, the presence of toluene seemed to affect ACF filtration performance to a lesser degree. Understanding these interactions is necessary for the ongoing development of ACF as dual respirator media for both PM and VOCs.

30 September 2026 in ACS Applied Engineering Materials
Verified
Journal Article
Open access
CKChandrima Karthik
Chandrima Karthik
GVGreeshma S. Vinoy
Greeshma S. Vinoy
Brie McMahanBrie McMahan
Brie McMahan
Claudiu T LunguClaudiu T Lungu
Claudiu T Lungu
Airborne heavy metal (HM) aerosols pose significant threats to human health, particularly in industrial settings where fine particulate matter (PM) mediates deep respiratory exposure. Here, we report a non-thermal plasma (NTP)-functionalized activated carbon fiber (ACF)/boron nitride nanotube (BNNT) hybrid filtration platform for enhanced aerosol HM capture and filtration. Plasma activation introduces surface functional moieties, while BNNT incorporation provides active sites and hierarchical structuring for particle entrapment and filtration. Filtration performance was evaluated using manganese chloride (MnCl2) and sodium chloride (NaCl) model systems. This work presents a potential scalable and environmentally relevant approach for advanced HM aerosol capture.

13 January 2026 in ACS Omega
Verified
Journal Article
Open access
Jacob S. SheddJacob S. Shedd
Jacob S. Shedd
EFEvan L. Floyd
Evan L. Floyd
JOJonghwa Oh
Jonghwa Oh
Brie McMahanBrie McMahan
Brie McMahan
Claudiu T LunguClaudiu T Lungu
Claudiu T Lungu
Volatile organic compounds (VOCs) are common sources of occupational exposure throughout a variety of industries. To protect personnel from overexposure, field industrial hygienists must conduct compliance sampling. In efforts to improve upon analytical sensitivity and time-to-knowledge of existing VOC exposure assessment methods, the industrial hygiene research group at UAB has developed a preanalytical technique known as photothermal desorption (PTD), which uses pulses of high-energy light to desorb analytes from thermally conductive, carbonaceous sorbents. To-date, the theoretical and conceptual groundwork for PTD have been laid, and advances have been made toward a first-generation, PTD-compatible diffusive sampler. However, additional characterizations of the prototype sampler’s performance are needed before the method is ready for in-field deployment. As such, the objectives of this study were 2-fold: (1) the primary objective was to determine the percent mass recovered via PTD of samples collected for various VOC analytes (i.e., toluene, n-hexane, isopropyl alcohol, and trichloroethylene), and (2) the secondary objective was to quantify the analyte adsorption capacities of buckypaper (BP) sorbents for each VOC of interest. The percent mass recovery of toluene, n-hexane, trichloroethylene, and isopropyl alcohol were found to be 0.60 ± 0.09, 1.2 ± 0.09, 1.1 ± 0.1, and 14.0 ± 1.0% per PTD pulse, and analyte adsorption capacities for BP sorbents were determined to be 152 ± 5 mg/g at 219 ppm toluene, 75 ± 42 mg/g at 292 ppm n-hexane, 104 ± 37 mg/g at 101 ppm trichloroethylene, and 105 ± 19 mg/g at 413 ppm isopropyl alcohol. The observed differences in desorption of analytes are likely attributed to varying types of weak intermolecular forces acting on aromatic rings, aliphatic chains, and polar moieties. While the large standard deviations in adsorption capacities may be explained by nonuniformity of nanotube alignment in respective sorbents. The early stage, prototype characterization data presented in this study, demonstrates the promising nature of PTD used with passive air samplers and provides a solid foundation for future development of the preanalytical technique and accompanying sampling devices.