Brinnae Bent

Mrs. Brinnae Bent

Duke University
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2016 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
James DieffenderferJames Dieffenderfer
James Dieffenderfer
HGHenry Goodell
Henry Goodell
SMSteven Mills
Steven Mills
MMMichael McKnight
Michael McKnight
Shanshan YaoShanshan Yao
Shanshan Yao
ABAlper Bozkurt
Alper Bozkurt
We present our efforts toward enabling a wearable sensor system that allows for the correlation of individual environmental exposures with physiologic and subsequent adverse health responses. This system will permit a better understanding of the impact of increased ozone levels and other pollutants on chronic asthma conditions. We discuss the inefficiency of existing commercial off-the-shelf components to achieve continuous monitoring and our system-level and nano-enabled efforts toward improving the wearability and power consumption. Our system consists of a wristband, a chest patch, and a handheld spirometer. We describe our preliminary efforts to achieve a submilliwatt system ultimately powered by the energy harvested from thermal radiation and motion of the body with the primary contributions being an ultralow-power ozone sensor, an volatile organic compounds sensor, spirometer, and the integration of these and other sensors in a multimodal sensing platform. The measured environmental parameters include ambient ozone concentration, temperature, and relative humidity. Our array of sensors also assesses heart rate via photoplethysmography and electrocardiography, respiratory rate via photoplethysmography, skin impedance, three-axis acceleration, wheezing via a microphone, and expiratory airflow. The sensors on the wristband, chest patch, and spirometer consume 0.83, 0.96, and 0.01 mW, respectively. The data from each sensor are continually streamed to a peripheral data aggregation device and are subsequently transferred to a dedicated server for cloud storage. Future work includes reducing the power consumption of the system-on-chip including radio to reduce the entirety of each described system in the submilliwatt range.

2 June 2021 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
BBBrinnae Bent
Brinnae Bent
PCPeter J. Cho
Peter J. Cho
MHMaria Henriquez
Maria Henriquez
AWApril Wittmann
April Wittmann
CTConnie Thacker
Connie Thacker
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
Prediabetes affects one in three people and has a 10% annual conversion rate to type 2 diabetes without lifestyle or medical interventions. Management of glycemic health is essential to prevent progression to type 2 diabetes. However, there is currently no commercially-available and noninvasive method for monitoring glycemic health to aid in self-management of prediabetes. There is a critical need for innovative, practical strategies to improve monitoring and management of glycemic health. In this study, using a dataset of 25,000 simultaneous interstitial glucose and noninvasive wearable smartwatch measurements, we demonstrated the feasibility of using noninvasive and widely accessible methods, including smartwatches and food logs recorded over 10 days, to continuously detect personalized glucose deviations and to predict the exact interstitial glucose value in real time with up to 84% and 87% accuracy, respectively. We also establish methods for designing variables using data-driven and domain-driven methods from noninvasive wearables toward interstitial glucose prediction.

14 July 2020 in Journal of Clinical and Translational Science
Verified
Journal Article
Open access
PDF file
BBBrinnae Bent
Brinnae Bent
KWKe Wang
Ke Wang
EGEmilia Grzesiak
Emilia Grzesiak
CJChentian Jiang
Chentian Jiang
YQYuankai Qi
Yuankai Qi
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
Introduction: Digital health is rapidly expanding due to surging healthcare costs, deteriorating health outcomes, and the growing prevalence and accessibility of mobile health (mHealth) and wearable technology. Data from Biometric Monitoring Technologies (BioMeTs), including mHealth and wearables, can be transformed into digital biomarkers that act as indicators of health outcomes and can be used to diagnose and monitor a number of chronic diseases and conditions. There are many challenges faced by digital biomarker development, including a lack of regulatory oversight, limited funding opportunities, general mistrust of sharing personal data, and a shortage of open-source data and code. Further, the process of transforming data into digital biomarkers is computationally expensive, and standards and validation methods in digital biomarker research are lacking. Methods: In order to provide a collaborative, standardized space for digital biomarker research and validation, we present the first comprehensive, open-source software platform for end-to-end digital biomarker development: The Digital Biomarker Discovery Pipeline (DBDP). Results: Here, we detail the general DBDP framework as well as three robust modules within the DBDP that have been developed for specific digital biomarker discovery use cases. Conclusions: The clear need for such a platform will accelerate the DBDP’s adoption as the industry standard for digital biomarker development and will support its role as the epicenter of digital biomarker collaboration and exploration.

9 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YJYIHANG JIANG
YIHANG JIANG
YQYuankai Qi
Yuankai Qi
WWWill Ke Wang
Will Ke Wang
BBBrinnae Bent
Brinnae Bent
RARobert Avram
Robert Avram
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
The dynamic time warping (DTW) algorithm is widely used in pattern matching and sequence alignment tasks, including speech recognition and time series clustering. However, DTW algorithms perform poorly when aligning sequences of uneven sampling frequencies. This makes it difficult to apply DTW to practical problems, such as aligning signals that are recorded simultaneously by sensors with different, uneven, and dynamic sampling frequencies. As multi-modal sensing technologies become increasingly popular, it is necessary to develop methods for high quality alignment of such signals. Here we propose a DTW algorithm called EventDTW which uses information propagated from defined events as basis for path matching and hence sequence alignment. We have developed two metrics, the error rate (ER) and the singularity score (SS), to define and evaluate alignment quality and to enable comparison of performance across DTW algorithms. We demonstrate the utility of these metrics on 84 publicly-available signals in addition to our own multi-modal biomedical signals. EventDTW outperformed existing DTW algorithms for optimal alignment of signals with different sampling frequencies in 37% of artificial signal alignment tasks and 76% of real-world signal alignment tasks.

17 June 2021 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
CCChia-Han Chiang
Chia-Han Chiang
CWCharles Wang
Charles Wang
KBKatrina Barth
Katrina Barth
SRShervin Rahimpour
Shervin Rahimpour
MTMichael Trumpis
Michael Trumpis
JVJonathan Viventi
Jonathan Viventi
Objective. Brain functions such as perception, motor control, learning, and memory arise from the coordinated activity of neuronal assemblies distributed across multiple brain regions. While major progress has been made in understanding the function of individual neurons, circuit interactions remain poorly understood. A fundamental obstacle to deciphering circuit interactions is the limited availability of research tools to observe and manipulate the activity of large, distributed neuronal populations in humans. Here we describe the development, validation, and dissemination of flexible, high-resolution, thin-film (TF) electrodes for recording neural activity in animals and humans. Approach. We leveraged standard flexible printed-circuit manufacturing processes to build high-resolution TF electrode arrays. We used biocompatible materials to form the substrate (liquid crystal polymer; LCP), metals (Au, PtIr, and Pd), molding (medical-grade silicone), and 3D-printed housing (nylon). We designed a custom, miniaturized, digitizing headstage to reduce the number of cables required to connect to the acquisition system and reduce the distance between the electrodes and the amplifiers. A custom mechanical system enabled the electrodes and headstages to be pre-assembled prior to sterilization, minimizing the setup time required in the operating room. PtIr electrode coatings lowered impedance and enabled stimulation. High-volume, commercial manufacturing enables cost-effective production of LCP-TF electrodes in large quantities. Main Results . Our LCP-TF arrays achieve 25× higher electrode density, 20× higher channel count, and 11× reduced stiffness than conventional clinical electrodes. We validated our LCP-TF electrodes in multiple human intraoperative recording sessions and have disseminated this technology to >10 research groups. Using these arrays, we have observed high-frequency neural activity with sub-millimeter resolution. Significance. Our LCP-TF electrodes will advance human neuroscience research and improve clinical care by enabling broad access to transformative, high-resolution electrode arrays.

8 April 2022 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
PCPeter Jaeho Cho
Peter Jaeho Cho
JYJaehan Yi
Jaehan Yi
EHEthan Ho
Ethan Ho
MSMobashir Hasan Shandhi
Mobashir Hasan Shandhi
YDYen Dinh
Yen Dinh
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
Digital health technologies, such as smartphones and wearable devices, promise to revolutionize disease prevention, detection, and treatment. Recently, there has been a surge of digital health studies where data are collected through a bring-your-own-device (BYOD) approach, in which participants who already own a specific technology may voluntarily sign up for the study and provide their digital health data. BYOD study design accelerates the collection of data from a larger number of participants than cohort design; this is possible because researchers are not limited in the study population size based on the number of devices afforded by their budget or the number of people familiar with the technology. However, the BYOD study design may not support the collection of data from a representative random sample of the target population where digital health technologies are intended to be deployed. This may result in biased study results and biased downstream technology development, as has occurred in other fields. In this viewpoint paper, we describe demographic imbalances discovered in existing BYOD studies, including our own, and we propose the Demographic Improvement Guideline to address these imbalances.