Jessilyn Dunn

Dr. Jessilyn Dunn

Pratt School of Engineering, Duke University, Durham, NC 27708, USA
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2020 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
BBBrinnae Bent
Brinnae Bent
BGBenjamin A. Goldstein
Benjamin A. Goldstein
WKWarren A. Kibbe
Warren A. Kibbe
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
As wearable technologies are being increasingly used for clinical research and healthcare, it is critical to understand their accuracy and determine how measurement errors may affect research conclusions and impact healthcare decision-making. Accuracy of wearable technologies has been a hotly debated topic in both the research and popular science literature. Currently, wearable technology companies are responsible for assessing and reporting the accuracy of their products, but little information about the evaluation method is made publicly available. Heart rate measurements from wearables are derived from photoplethysmography (PPG), an optical method for measuring changes in blood volume under the skin. Potential inaccuracies in PPG stem from three major areas, includes (1) diverse skin types, (2) motion artifacts, and (3) signal crossover. To date, no study has systematically explored the accuracy of wearables across the full range of skin tones. Here, we explored heart rate and PPG data from consumer- and research-grade wearables under multiple circumstances to test whether and to what extent these inaccuracies exist. We saw no statistically significant difference in accuracy across skin tones, but we saw significant differences between devices, and between activity types, notably, that absolute error during activity was, on average, 30% higher than during rest. Our conclusions indicate that different wearables are all reasonably accurate at resting and prolonged elevated heart rate, but that differences exist between devices in responding to changes in activity. This has implications for researchers, clinicians, and consumers in drawing study conclusions, combining study results, and making health-related decisions using these devices.

14 April 2020 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
JGJennifer C. Goldsack
Jennifer C. Goldsack
ACAndrea Coravos
Andrea Coravos
JBJessie P. Bakker
Jessie P. Bakker
BBBrinnae Bent
Brinnae Bent
ADAriel V. Dowling
Ariel V. Dowling
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
Digital medicine is an interdisciplinary field, drawing together stakeholders with expertize in engineering, manufacturing, clinical science, data science, biostatistics, regulatory science, ethics, patient advocacy, and healthcare policy, to name a few. Although this diversity is undoubtedly valuable, it can lead to confusion regarding terminology and best practices. There are many instances, as we detail in this paper, where a single term is used by different groups to mean different things, as well as cases where multiple terms are used to describe essentially the same concept. Our intent is to clarify core terminology and best practices for the evaluation of Biometric Monitoring Technologies (BioMeTs), without unnecessarily introducing new terms. We focus on the evaluation of BioMeTs as fit-for-purpose for use in clinical trials. However, our intent is for this framework to be instructional to all users of digital measurement tools, regardless of setting or intended use. We propose and describe a three-component framework intended to provide a foundational evaluation framework for BioMeTs. This framework includes (1) verification, (2) analytical validation, and (3) clinical validation. We aim for this common vocabulary to enable more effective communication and collaboration, generate a common and meaningful evidence base for BioMeTs, and improve the accessibility of the digital medicine field.

24 May 2021 in Nature Medicine
Verified
Journal Article
Closed access
PDF file
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
LKLukasz Kidzinski
Lukasz Kidzinski
RRRyan Runge
Ryan Runge
DWDaniel Witt
Daniel Witt
JHJennifer L. Hicks
Jennifer L. Hicks
MSMichael P Snyder
Michael P Snyder

1 November 2023 in Physiological Measurement
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
John AllenJohn Allen
John Allen
Raquel BailónRaquel Bailón
Raquel Bailón
SBStephanie Baker
Stephanie Baker
JBJoachim A Behar
Joachim A Behar
TZTingting Zhu
Tingting Zhu
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.

2 May 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
Abu Baker SheikhAbu Baker Sheikh
Abu Baker Sheikh
PSPaul A. Sobotka
Paul A. Sobotka
IGIshan Garg
Ishan Garg
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
AMAbdul Mannan Khan Minhas
Abdul Mannan Khan Minhas
MFMarat Fudim
Marat Fudim
Recent advances in wearable technology through convenient and cuffless systems will enable continuous, noninvasive monitoring of blood pressure (BP), heart rate, and heart rhythm on both longitudinal 24‐hour measurement scales and high‐frequency beat‐to‐beat BP variability and synchronous heart rate variability and changes in underlying heart rhythm. Clinically, BP variability is classified into 4 main types on the basis of the duration of monitoring time: very‐short‐term (beat to beat), short‐term (within 24 hours), medium‐term (within days), and long‐term (over months and years). BP variability is a strong risk factor for cardiovascular diseases, chronic kidney disease, cognitive decline, and mental illness. The diagnostic and therapeutic value of measuring and controlling BP variability may offer critical targets in addition to lowering mean BP in hypertensive populations.

2 June 2021 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
BBBrinnae Bent
Brinnae Bent
PCPeter J. Cho
Peter J. Cho
MHMaria Henriquez
Maria Henriquez
AWApril Wittmann
April Wittmann
CTConnie Thacker
Connie Thacker
Jessilyn DunnJessilyn Dunn
Jessilyn Dunn
Prediabetes affects one in three people and has a 10% annual conversion rate to type 2 diabetes without lifestyle or medical interventions. Management of glycemic health is essential to prevent progression to type 2 diabetes. However, there is currently no commercially-available and noninvasive method for monitoring glycemic health to aid in self-management of prediabetes. There is a critical need for innovative, practical strategies to improve monitoring and management of glycemic health. In this study, using a dataset of 25,000 simultaneous interstitial glucose and noninvasive wearable smartwatch measurements, we demonstrated the feasibility of using noninvasive and widely accessible methods, including smartwatches and food logs recorded over 10 days, to continuously detect personalized glucose deviations and to predict the exact interstitial glucose value in real time with up to 84% and 87% accuracy, respectively. We also establish methods for designing variables using data-driven and domain-driven methods from noninvasive wearables toward interstitial glucose prediction.