Bruno BRAJON

Mr. Bruno BRAJON

Melexis, Bevaix, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2023 in IEEE Access
Verified
Journal Article
Open access
Bruno BRAJONBruno BRAJON
Bruno BRAJON
EGEnrico Gasparin
Enrico Gasparin
GCGael Close
Gael Close
This survey paper compiles and benchmarks the performance of integrated magnetic sensors, in terms of their noise and full-scale magnetic field. In total, we collected performance metrics of 31 sensors realized in various technologies. For each sensor, we derived a noise model to estimate the noise under the same conditions. We obtained a comprehensive benchmark with a focus on integrated devices. We also measured the noise spectrum of 11 of those sensors to confirm our noise model. Given that for many emerging applications, such as tactile, current, torque and biomagnetic sensing, the signal of interest is the field gradient to reject magnetic stray fields, we extended the benchmark to gradiometers. We developed a low-noise measurement setup and a low-field gradient (full scale: 10 μT/mm) generation setup to characterize magnetic gradiometers in this regime. The paper discusses the key sensor trade-off between precision and range, and summarizes the technology trends graphically on a trade-off curve, providing broad insight.

10 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Bruno BRAJONBruno BRAJON
Bruno BRAJON
LLLorenzo Lugani
Lorenzo Lugani
GCGael Close
Gael Close
Magnetic and inductive sensors are the dominant technologies in angular position sensing for automotive applications. This paper introduces a new angular sensor: a hybrid concept combining the magnetic Hall and inductive principles. A magnetic Hall transducer provides an accurate angle from 0° to 180°, whereas an inductive transducer provides a coarse angle from 0° to 360°. For this novel concept, a hybrid target with a magnetic and inductive signature is also needed. Using the two principles at the same time enables superior performances, in terms of range, compactness and robustness, that are not possible when used separately. We realized and characterized a prototype. The prototype achieves a 360° range, has a high accuracy and is robust against mechanical misalignments, stray fields and stray metals. The measurement results demonstrate that the two sensing principles are completely independent, thereby opening the doors for hybrid optimum magnetic–inductive designs beyond the usual trade-offs (range vs. resolution, size vs. robustness to misalignment).

1 May 2020
Verified
Conference Paper
Closed access
PMPaul Motreuil-Ragot
Paul Motreuil-Ragot
AHAndres Hunt
Andres Hunt
DKDhanesh Kasi
Dhanesh Kasi
Bruno BRAJONBruno BRAJON
Bruno BRAJON
AMArn van Den Maagdenberg
Arn van Den Maagdenberg
PSPasqualina M. Sarro
Pasqualina M. Sarro
Organ-on-chip (OoC) devices are in rising demand for high-throughput and low-cost development and toxico-logical screening of chemicals and pharmaceuticals, as they accurately mimic in vitro physiological conditions as in the human body. In particular, OoCs are urgently needed for screening cardiovascular drug toxicity. Physiological relevance of cardiovascular cell cultures requires moving substrates. To date cell culture substrates have been commonly actuated by pneumatic systems, which are bulky, expensive and non-user-friendly, and may thus limit the adoption of OoCs by researchers and industry. In this paper we propose the first actuating and sensing smart material-based OoC device and demonstrate its functionality by culturing human vascular smooth muscle cells (vSMC). Our device utilizes a single ionic polymer metal composite (IPMC)-based transducer to provide both actuation and sensing. The soft IPMC substrate allows to intermittently apply cyclic loading to tissues and to sense their spontaneous contractions. We integrated the transducer within a compact, easy-to-operate, economically affordable and scalable OoC prototype, which achieves an actuation range of 0.2 mm and 0.72 V/mm sensing resolution. The 0.1 % strain induced by actuation on cells accurately corresponds to in vitro strains for vSMCs. We successfully grew vSMCs on the IPMC substrate, and actuated them for 150 min at 1 Hz. Fluorescent staining showed no evidence of adverse effects. These results are a major step towards versatile OoCs for a wide variety of biological modelling of human tissues.

6 September 2024 in TechRxiv
Verified
Preprint
Open access
Bruno BRAJONBruno BRAJON
Bruno BRAJON
CSChristian Schott
Christian Schott
GCGael Close
Gael Close
We present a novel high-accuracy rotary magnetic sensor system composed of a two-track coded multi-pole magnet and a dual-spot multi-axes magnetic sensor. The novelty is the measurement of two orthogonal magnetic field components in each of the two sensing spots of the sensor, one associated with each magnet track. As the two orthogonal signals in each spot are naturally in quadrature, i.e. they represent a sine and a cosine signal, the measurement principle is virtually independent of the magnet pole size and pitch. We can therefore design a magnet with much larger poles which in turn generate stronger magnetic flux, allowing for an increased air gap between sensor and magnet. The calibrated encoder system was characterized to deliver 13 bits of absolute accuracy and 17 bits of resolution over the full 360° range.

29 October 2023
Verified
Conference Paper
Closed access
Bruno BRAJONBruno BRAJON
Bruno BRAJON
CSChristian Christian Schott Schott
Christian Christian Schott Schott
GCGael Close
Gael Close
We demonstrate a novel high-accuracy rotary magnetic sensor system composed of a two-track coded multipole magnet and a dual-spot multi-axes magnetic sensor. The novelty is the measurement of two orthogonal magnetic field components in each of the two sensing spots of the sensor, one associated with each magnet track. The demonstrator shows the position tolerant construction and large airgap and the demo itself shows how the calibrated encoder system performs 13 bits of absolute angular accuracy and 17 bits of resolution over the full 360º range.