Marco Bustamante Balén

Prof. Marco Bustamante Balén

Gastrointestinal Endoscopy Unit, Hospital Universitari i Politècnic La Fe, Valencia
+1

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2019 in Endoscopy
Verified
Journal Article
Closed access
PDF file
RBRaf Bisschops
Raf Bisschops
JEJames E. East
James E. East
CHCesare Hassan
Cesare Hassan
YHYark Hazewinkel
Yark Hazewinkel
MKMichel Kaminski
Michel Kaminski
EDEvelien Dekker
Evelien Dekker
Main Recommendations: 1 ESGE suggests that high definition endoscopy, and dye or virtual chromoendoscopy, as well as add-on devices, can be used in average risk patients to increase the endoscopist’s adenoma detection rate. However, their routine use must be balanced against costs and practical considerations.Weak recommendation, high quality evidence. 2 ESGE recommends the routine use of high definition systems in individuals with Lynch syndrome.Strong recommendation, high quality evidence. 3 ESGE recommends the routine use, with targeted biopsies, of dye-based pancolonic chromoendoscopy or virtual chromoendoscopy for neoplasia surveillance in patients with long-standing colitis.Strong recommendation, moderate quality evidence. 4 ESGE suggests that virtual chromoendoscopy and dye-based chromoendoscopy can be used, under strictly controlled conditions, for real-time optical diagnosis of diminutive (≤ 5 mm) colorectal polyps and can replace histopathological diagnosis. The optical diagnosis has to be reported using validated scales, must be adequately photodocumented, and can be performed only by experienced endoscopists who are adequately trained, as defined in the ESGE curriculum, and audited.Weak recommendation, high quality evidence. 5 ESGE recommends the use of high definition white-light endoscopy in combination with (virtual) chromoendoscopy to predict the presence and depth of any submucosal invasion in nonpedunculated colorectal polyps prior to any treatment. Strong recommendation, moderate quality evidence. 6 ESGE recommends the use of virtual or dye-based chromoendoscopy in addition to white-light endoscopy for the detection of residual neoplasia at a piecemeal polypectomy scar site. Strong recommendation, moderate quality evidence. 7 ESGE suggests the possible incorporation of computer-aided diagnosis (detection and characterization of lesions) to colonoscopy, if acceptable and reproducible accuracy for colorectal neoplasia is demonstrated in high quality multicenter in vivo clinical studies. Possible significant risks with implementation, specifically endoscopist deskilling and over-reliance on artificial intelligence, unrepresentative training datasets, and hacking, need to be considered. Weak recommendation, low quality evidence.

1 November 2019 in Gastroenterology
Verified
Journal Article
Closed access
EAEduardo Albéniz
Eduardo Albéniz
MÁMarco Antonio Álvarez-González
Marco Antonio Álvarez-González
JEJorge C. Espinós
Jorge C. Espinós
ONOscar Nogales
Oscar Nogales
CGCarlos Guarner
Carlos Guarner
MEMónica Enguita-Germán
Mónica Enguita-Germán

9 September 2016 in Gut
Verified
Journal Article
Closed access
PDF file
SCSabela Carballal
Sabela Carballal
SMSandra Maisterra
Sandra Maisterra
ALAntonio López-Serrano
Antonio López-Serrano
AGAntonio Zebenzuy Gimeno García
Antonio Zebenzuy Gimeno García
MVMaría Isabel Vera
María Isabel Vera
MPMaría Pellisé
María Pellisé
Objective Outside clinical trials, the effectiveness of chromoendoscopy (CE) for long-standing IBD surveillance is controversial. We aimed to assess the effectiveness of CE for neoplasia detection and characterisation, in real-life. Design From June 2012 to 2014, patients with IBD were prospectively included in a multicentre cohort study. Each colonic segment was evaluated with white light followed by 0.4% indigo carmine CE. Specific lesions' features were recorded. Optical diagnosis was assessed. Dysplasia detection rate between expert and non-expert endoscopists and learning curve were ascertained. Results Ninety-four (15.7%) dysplastic (1 cancer, 5 high-grade dysplasia, 88 low-grade dysplasia) and 503 (84.3%) non-dysplastic lesions were detected in 350 patients (47% female; mean disease duration: 17 years). Colonoscopies were performed with standard definition (41.5%) or high definition (58.5%). Dysplasia miss rate with white light was 40/94 (57.4% incremental yield for CE). CE-incremental detection yield for dysplasia was comparable between standard definition and high definition (51.5% vs 52.3%, p=0.30). Dysplasia detection rate was comparable between expert and non-expert (18.5% vs 13.1%, p=0.20). No significant learning curve was observed (8.2% vs 14.2%, p=0.46). Sensitivity, specificity, and positive and negative predictive values for dysplasia optical diagnosis were 70%, 90%, 58% and 94%, respectively. Endoscopic characteristics predictive of dysplasia were: proximal location, loss of innominate lines, polypoid morphology and Kudo pit pattern III–V. Conclusions CE presents a high diagnostic yield for neoplasia detection, irrespectively of the technology and experience available in any centre. In vivo, CE optical diagnosis is highly accurate for ruling out dysplasia, especially in expert hands. Lesion characteristics can aid the endoscopist for in situ therapeutic decisions. Trial registration number NCT02543762.

1 April 2013 in Journal of Crohn's and Colitis
Verified
Journal Article
Closed access
JPJosé María Paredes
José María Paredes
TRTomás Ripollés
Tomás Ripollés
XCXavier Cortés
Xavier Cortés
NMNadia Moreno
Nadia Moreno
MMMaría Jesús Martínez
María Jesús Martínez
EMEduardo Moreno-Osset
Eduardo Moreno-Osset
The aim of this study was to assess whether the contrast-enhanced ultrasonography (CEUS) can increase the value of the ultrasonography in the study of postoperative recurrence of Crohn's disease (CD). 60 patients with CD who had previously undergone ileocolic resection underwent prospectively both CEUS and colonoscopy within a 3-day period. The sonographic examination included evaluation of bowel wall thickness, transmural complications, colour Doppler grade and contrast-enhanced US. In addition a sonographic score was established. The capacity of CEUS to diagnose endoscopic recurrence, as well as its severity, was assessed by calculating the sensitivity, specificity and positive and negative predictive values, accuracy and odds ratio, with their respective 95% confidence intervals. The areas under the receiver operating characteristic (ROC) curves were also calculated. 49 out of 60 patients showed endoscopic postoperative recurrence. Severe endoscopic recurrence was present in 34 patients (57%). Classic ultrasound parameters (wall thickness >3mm and colour Doppler flow) revealed an accuracy of 88.3% for the diagnosis of recurrence. Sonographic score 2, including thickness >5mm or contrast enhancement >46%, improved the results with a sensitivity, specificity and accuracy of 98%, 100% and 98.3%, respectively, in the diagnosis of endoscopic recurrence. The area under the ROC curve was 0.99, in remarkable agreement with endoscopy (k: 0.946). Sonographic score 3, including thickness >5mm, contrast enhancement >70% or fistula identified 32 out of 34 (94.1%) severe endoscopic recurrences. The area under the ROC curve was 0.836, in good agreement with endoscopy (k: 0.688). CEUS shows excellent sensitivity and specificity for the diagnosis of postoperative recurrence in CD and can also detect severe recurrences.

1 January 2019 in Gastroenterology
Verified
Journal Article
Closed access
PDF file
IPIgnasi Puig
Ignasi Puig
MLMaría López-Cerón
María López-Cerón
AAAnna Arnau
Anna Arnau
ÒRÒria Rosiñol
Òria Rosiñol
Miriam CuatrecasasMiriam Cuatrecasas
Miriam Cuatrecasas
NANadia Ascon
Nadia Ascon

6 December 2021 in Endoscopy
Verified
Journal Article
Closed access
PDF file
BHBritt B. S. L. Houwen
Britt B. S. L. Houwen
CHCesare Hassan
Cesare Hassan
VCVeerle M. H. Coupé
Veerle M. H. Coupé
MGMarjolein J. E. Greuter
Marjolein J. E. Greuter
YHYark Hazewinkel
Yark Hazewinkel
EDEvelien Dekker
Evelien Dekker
Background The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 – 5 mm).Methods A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds.Recommendation 1 In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm in the rectosigmoid. Histopathology is used as the gold standard.Level of agreement 95 %.Recommendation 2 In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm. Histopathology is used as the gold standard.Level of agreement 100 %.Conclusion The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.