Commercial archwires NiTiCu (Ormco) and NiTi (Morelli) and samples of the corresponding raw materials were tested to assess the influence of Cu addition and sterilization on the corrosion resistance and biocompatibility. Raw materials samples and commercial archwires exhibited similar corrosion resistance when compared. The addition of Cu decreased the corrosion resistance of NiTi alloy, whiling the sterilization process had no influence. The biocompatibility tests were carried out in different extracts of the alloys and no cytotoxicity effects were observed for the ionic concentrations used. SEM and Confocal laser analysis permitted to observe the localized corrosion morphology obtained after anodic polarization tests. Although Cu addition on NiTi can be introduced to better adjust the mechanical resistance, this third element induced detrimental effect on the corrosion resistance of raw materials and commercial archwires.
28 August 2020 in Journal of Bio- and Tribo-Corrosion
Metastable titanium alloys have been developed for biomedical use due to their lower elastic modulus, combined with high strength, good ductility, and excellent corrosion resistance. In this study, the electrochemical corrosion resistance of the alternative Ti-23.6Nb-5.1Mo-6.7Zr alloy was investigated. The alloy was initially homogenized at 1000 °C for 24 h and then tested under different processing conditions: 90% cold rolling; 90% cold rolling followed by annealing at 950 °C for 1 h and water quenching; and 90% cold rolling followed by aging at 300 °C, 400 °C, and 500 °C for 4 h each. Electrochemical behavior was assessed using anodic polarization, open circuit potential (OCP), and electrochemical impedance spectroscopy (EIS) tests in a synthetic solution (Ringer’s solution) to simulate body fluid. The obtained results demonstrate the stability of the passive film formed of the conventional and modified alloys, considering long-term use in the human body, regardless of the volumetric fraction and phase distribution across the various processing routes studied as β, α, α″ and ω. The electrochemical parameters, combined with Young’s modulus and hardness of the alternative alloys, enable the definition of a multicriteria selection method of the most suitable mechanical process routes to be used. The application focused on components of functional femoral stems.