Carla Zamora-Perarnau

Ms. Carla Zamora-Perarnau


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2023 in Frontiers in Veterinary Science
Verified
Journal Article
Open access
CZCarla Zamora-Perarnau
Carla Zamora-Perarnau
MMMauro Malvè
Mauro Malvè
RFRocío Fernández-Parra
Rocío Fernández-Parra
Intoduction: In veterinary medicine, airway management of cats under general anesthesia is performed with an endotracheal tube (ETT) or supraglottic airway device (SGAD). This study aims to describe the use of computational fluid dynamics (CFD) to assess the velocities, pressures, and resistances of cats with ETT or SGAD.Methods: A geometrical reconstruction model of the device, trachea, and lobar bronchi was carried out from computed tomography (CT) scans that include the head, neck, and thorax. Twenty CT scans of cats under general anesthesia using ETT (n = 10) and SGAD (n = 10) were modeled and analyzed. An inspiratory flow of 2.4 L/min was imposed in each model and velocity (m/s), general and regional pressures (cmH2O) were computed. General resistance (cmH2O/L/min) was calculated using differential pressure differences between the device inlet and lobar bronchi. Additionally, regional resistances were calculated at the device’s connection with the breathing circuit (region A), at the glottis area for the SGAD, and the area of the ETT exit (bevel) (region B) and the device itself (region C).Results: Recirculatory flow and high velocities were found at the ETT’s bevel and at the glottis level in the SGAD group. The pressure gradient (Δp) was more enhanced in the ETT cases compared with the SGAD cases, where the pressure change was drastic. In region A, the Δp was higher in the ETT group, while in regions B and C, it was higher in the SGAD group. The general resistance was not statistically significant between groups (p = 0.48). Higher resistances were found at the region A (p = <0.001) in the ETT group. In contrast, the resistance was higher in the SGAD cases at the region B (p = 0.001).Discussion: Overall, the provided CT-based CFD analysis demonstrated regional changes in airway pressure and resistance between ETT and SGAD during anesthetic flow conditions. Correct selection of the airway device size is recommended to avoid upper airway obstruction or changes in flow parameters.

26 February 2026 in Journal of Biomechanics
Verified
Journal Article
Closed access
CZCarla Zamora-Perarnau
Carla Zamora-Perarnau
MMMauro Malvè
Mauro Malvè
RFRocío Fernández-Parra
Rocío Fernández-Parra

9 September 2026 in Animals
Verified
Journal Article
Open access
PDF file
CZCarla Zamora-Perarnau
Carla Zamora-Perarnau
MMMauro Malve
Mauro Malve
PSpatricia sebastian
patricia sebastian
RFRocío Fernández-Parra
Rocío Fernández-Parra
Pulmonic stenosis (PS) is one of the most common congenital cardiac diseases in dogs. Although echocardiography and computed tomographic angiography (CTA) provide valuable diagnostic and anatomical information, the hemodynamic consequences of PS remain incompletely characterized. This study describes patient-specific pulmonary artery hemodynamics in dogs with and without PS using computational fluid dynamics (CFD). Contrast-enhanced CTA and echocardiographic data from five dogs with PS and five control dogs without PS were used to reconstruct three-dimensional pulmonary artery geometries and generate patient-specific CFD models. Pressure drop (Δp), blood flow velocity, mean wall shear stress (WSS), time-averaged WSS (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and pulmonary artery resistance were quantified and compared between groups. Dogs with PS exhibited markedly increased transvalvular pressure gradients, peak flow velocities, and pulmonary artery resistance, together with high-velocity jets and localized post-stenotic recirculation that were absent in control dogs. Mean WSS and TAWSS tended to be higher in the PS group, whereas OSI values were similar between groups. In contrast, RRT was significantly lower (p = 0.032) in dogs with PS. These findings demonstrate that patient-specific CFD enables detailed characterization of pulmonary artery hemodynamics in canine PS, providing information that complements conventional imaging. Although its clinical utility in veterinary medicine has yet to be fully established, CFD can provide valuable insight into flow behavior and disease pathophysiology; however, its ability to yield precise, clinically applicable quantitative values remains limited. This approach shows promise for future applications in the clinical evaluation of PS and other cardiovascular diseases, although further studies are warranted to determine its clinical relevance in veterinary medicine.

11 October 2026 in Animals
Verified
Journal Article
Open access
PDF file
LFLaura Librán Ferreira
Laura Librán Ferreira
Iván Rodríguez ArmasIván Rodríguez Armas
Iván Rodríguez Armas
CZCarla Zamora-Perarnau
Carla Zamora-Perarnau
NINicolas Israeliantz
Nicolas Israeliantz
VCVicente Cervera
Vicente Cervera
Pathological lymphovenous communications are poorly characterized in veterinary medicine, and their computed tomographic features and clinical significance remain unknown. This retrospective case series aimed to describe contrast-enhanced computed tomography findings of suspected spontaneous lymphovenous communications in three cats. All cats had dilated, tortuous vessels arising from portal venous tributaries and extending to the cisterna chyli, originating from the splenic vein in two cats and the cranial mesenteric vein in one. The cisterna chyli and thoracic duct were consistently dilated and contrast-enhancing, and reduced portal vein calibre cranial to the communications was present in all cats. Concurrent findings included pleural or peritoneal effusion and subcutaneous edema, with chylous pleural effusion confirmed in two cats. The recurrent anatomical distribution and associated portal and lymphatic abnormalities suggest that these communications may represent the enlargement and functional recruitment of pre-existing lymphovenous pathways in response to acquired portal and/or lymphatic hemodynamic disturbances, although a congenital origin cannot be excluded. Contrast-enhanced computed tomography may allow the recognition and anatomical characterization of suspected pathological lymphovenous communications in cats and should be considered when anomalous portal vessels are associated with concurrent cisterna chyli and thoracic duct abnormalities.