Mauro Malve

Dr. Mauro Malve

Department of Engineering, Universidad Pública de Navarra, Campus Arrosadía s/n, Edificio de los Pinos, E-31005, Pamplona, Navarra, Spain
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
CCClaudio Chiastra
Claudio Chiastra
FMFrancesco Migliavacca
Francesco Migliavacca
MMMiguel Ángel Martínez
Miguel Ángel Martínez
MMMauro Malve
Mauro Malve

2 July 2014 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MMMauro Malve
Mauro Malve
AGAhmed M Gharib
Ahmed M Gharib
SYS. K. Yazdani
S. K. Yazdani
GFG. Finet
G. Finet
MMM. A. Martínez
M. A. Martínez
JOJ. Ohayon
J. Ohayon

21 March 2015 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
ALAlicia Laborda
Alicia Laborda
WKWilliam T. Kuo
William T. Kuo
Ignatios Ioakeim-SkoufaIgnatios Ioakeim-Skoufa
Ignatios Ioakeim-Skoufa
IBIgnacio de Blas
Ignacio de Blas
MMMauro Malve
Mauro Malve
MGMiguel Angel De Gregorio
Miguel Angel De Gregorio

7 April 2021 in Mathematics
Verified
Journal Article
Open access
PDF file
MLManuel Lagache
Manuel Lagache
RCRicardo Coppel
Ricardo Coppel
GFGérard Finet
Gérard Finet
FDFrançois Derimay
François Derimay
RPRoderic I. Pettigrew
Roderic I. Pettigrew
MMMauro Malve
Mauro Malve
Despite significant progress, malapposed or overlapped stents are a complication that affects daily percutaneous coronary intervention (PCI) procedures. These malapposed stents affect blood flow and create a micro re-circulatory environment. These disturbances are often associated with a change in Wall Shear Stress (WSS), Time-averaged WSS (TAWSS), relative residence time (RRT) and oscillatory character of WSS and disrupt the delicate balance of vascular biology, providing a possible source of thrombosis and restenosis. In this study, 2D axisymmetric parametric computational fluid dynamics (CFD) simulations were performed to systematically analyze the hemodynamic effects of malapposition and stent overlap for two types of stents (drug-eluting stent and a bioresorbable stent). The results of the modeling are mainly analyzed using streamlines, TAWSS, oscillatory shear index (OSI) and RRT. The risks of restenosis and thrombus are evaluated according to commonly accepted thresholds for TAWSS and OSI. The small malapposition distances (MD) cause both low TAWSS and high OSI, which are potential adverse outcomes. The region of low OSI decrease with MD. Overlap configurations produce areas with low WSS and high OSI. The affected lengths are relatively insensitive to the overlap distance. The effects of strut size are even more sensitive and adverse for overlap configurations compared to a well-applied stent.

1 April 2020 in Journal of Biomechanics
Verified
Journal Article
Closed access
MCM. Cilla
M. Cilla
MCM. Casales
M. Casales
EPE. Peña
E. Peña
MMM.A. Martínez
M.A. Martínez
MMMauro Malve
Mauro Malve

30 March 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BCBorja Catalán-Echeverría
Borja Catalán-Echeverría
MKMichael E. Kelly
Michael E. Kelly
LPLissa Peeling
Lissa Peeling
DBDonald Bergstrom
Donald Bergstrom
Xiongbiao ChenXiongbiao Chen
Xiongbiao Chen
MMMauro Malve
Mauro Malve
Flow-diverting stents (FDSs) show considerable promise for the treatment of cerebral aneurysms by diverting blood flow away from the aneurysmal sacs, however, post-treatment complications such as failure of occlusion and subarachnoid haemorrhaging remain and vary with the FDS used. Based on computational fluid dynamics (CFD), this study aimed to investigate the performance of a new biodegradable stent as compared to two metallic commercially available FDSs. CFD models were developed for an idealized cerebral artery with a sidewall aneurysmal sac treated by deploying the aforementioned stents of different porosities (90, 80, and 70 % ) respectively. By using these models, the simulation and analysis were performed, with a focus on comparing the local hemodynamics or the blood flow in the stented arteries as compared to the one without the stent deployment. For the comparison, we computed and compared the flow velocity, wall shear stress (WSS) and pressure distributions, as well as the WSS related indices, all of which are of important parameters for studying the occlusion and potential rupture of the aneurysm. Our results illustrate that the WSS decreases within the aneurysmal sac on the treated arteries, which is more significant for the stents with lower porosity or finer mesh. Our results also show that the maximum WSS near the aneurysmal neck increases regardless of the stents used. In addition, the WSS related indices including the time-average WSS, oscillatory shear index and relative residence time show different distributions, depending on the FDSs. Together, we found that the finer mesh stents provide more flow reduction and smaller region characterized by high oscillatory shear index, while the new stent has a higher relative residence time.