Carmen Sánchez

Ms. Carmen Sánchez

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2025 in Polymers
Verified
Journal Article
Open access
PDF file
CSCarmen Sánchez
Carmen Sánchez
AJAurora Pérez Jiménez
Aurora Pérez Jiménez
MMMauro Malve
Mauro Malve
Cristina DíazCristina Díaz
Cristina Díaz
Polylactic acid (PLA) is a bioresorbable and biocompatible material and is a promising alternative to the current materials used for permanent implants as it has osteosynthesis properties. However, this material has some drawbacks due to its low mechanical and thermal resistance after 3D printing. Extensive research has been conducted to improve the properties of this material, for example, with the addition of other compounds, such as magnesium (Mg) or Hydroxyapatite (HA). These reinforced materials have been shown to reduce the internal stress of the matrix of PLA, improving the thermal, optical and structural properties of the material, even though the performance achieved is lower than needed to be implanted. In addition, although it is known that the addition of Mg or HA affects the mechanical performance of the material, mechanical properties have not been studied in the literature. Thus, the aim of this study is to research the effect of thermal post-processing based on annealing of composites made of PLA with Mg and PLA with HA, manufactured by fused filament fabrication, with the goal of finding an improvement in the mechanical properties of these materials. As a result, different designs of annealing processes have been studied with different reinforced materials and their mechanical properties have been compared, studying axial traction and compression, radial compression as well as flexibility, among others. The comparative results achieved show the relevance of the design of the annealing process for the improvement of the mechanical properties of these materials.

15 August 2025 in Polymers
Verified
Journal Article
Open access
PDF file
AJAurora Pérez Jiménez
Aurora Pérez Jiménez
CSCarmen Sánchez
Carmen Sánchez
SPSandra Perez
Sandra Perez
NLNoelia Landa
Noelia Landa
Cristina DíazCristina Díaz
Cristina Díaz
MMMauro Malve
Mauro Malve
Endotracheal prosthesis placement is employed as a therapeutic intervention for tracheal lesions in cases where conventional surgical approaches are not feasible. The learning curve for endotracheal stent placement can vary depending on the type of stent, the training environment, and the clinician’s prior experience; however, it is generally considered moderately complex. Inadequate practice can have serious consequences, as the procedure involves a critical area such as the airway. The main risks and complications associated with inadequate technique or improper execution can include stent migration, formation of granulation tissue or hyperplasia, tracheal or pulmonary infection, obstruction or fracture of the stent, hemorrhage and tracheal perforation, among others. The purpose of the present study is to summarize important information and evaluate the role of different material features in the 3D printing manufacturing of an appropriate tracheobronchial medical device, which should be as appropriate as possible to facilitate placement during surgical practice. A complex stent design was fabricated using three different biodegradable materials, polycaprolactone (PCL), polydioxanone (PDO), and polymer blend of polylactic acid/polycaprolactone (PLA/PCL), through additive manufacturing, specifically fused filament fabrication (FFF)3D printing. Parameter optimization of the 3D printing process was required for each material to achieve an adequate geometric quality of the stent. Experimental analyses were conducted to characterize the mechanical properties of the printed stents. Flexural strength and radial compression resistance were evaluated, with particular emphasis on radial force due to its clinical relevance in preventing collapse after implantation in the trachea. The results provide valuable insights into how material selection could influence device behavior during placement to support surgical requirements.

Verified
Journal Article
Open access
PDF file
AAAda Ayechu-Abendaño
Ada Ayechu-Abendaño
LCLetizia Cella
Letizia Cella
CSCarmen Sánchez
Carmen Sánchez
CMCarmen Sánchez Matás
Carmen Sánchez Matás
JLJosé Luis López-Villalobos
José Luis López-Villalobos
MMMauro Malve
Mauro Malve
Current airway stents, including silicone and metallic devices, remain associated with important complications such as migration, restenosis, mucus retention and the need for repeated interventions. Biodegradable stents offer a promising alternative by providing temporary mechanical support while avoiding the long-term presence of a permanent implant. However, the influence of stent geometry and material properties on their mechanical performance and interaction with airway tissue is still not fully understood. This study presents a computational framework integrating computer-aided design and finite element analysis to investigate the mechanical behaviour of biodegradable tracheobronchial stents. Two stent architectures (X-pattern and W-pattern) were analysed over a range of wire thicknesses using two biodegradable materials: a PLA/PCL; 70/30 wt.% blend and AZ31 magnesium alloy. Radial compression, diameter recovery after radial compression and stent–tissue interaction simulations were performed to evaluate the influence of geometry, material selection and design parameters on device performance. The results suggested that both stent geometry and material properties strongly influence the mechanical behaviour of biodegradable airway stents, although they affect different aspects of the stent–tissue interaction. The X-pattern consistently exhibited greater resistance to radial compression, lower elastic diameter recovery after radial compression and improved maintenance of the expanded lumen compared with the W-pattern. Material properties primarily affected the magnitude of the mechanical response, as further confirmed by the quantitative contact-pressure analysis, with AZ31 providing greater radial support, while the spatial distributions of stress and strain within the tracheal wall were mainly governed by the stent architecture. Based on the computational analyses, X-pattern stents manufactured from the PLA/PCL; 70/30 wt.% blend were selected for in vivo evaluation in a rabbit model. Endoscopic observations revealed tissue features that were qualitatively consistent with the mechanical patterns predicted by the numerical simulations, although no direct causal relationship can be established from the available observations. These findings support the ability of the proposed framework to represent the principal aspects of stent–tissue interaction. The proposed computational framework provides a practical tool for the rational design and mechanical assessment of biodegradable airway stents and may facilitate the future development of customised airway prostheses.

26 September 2026 in Materials
Verified
Journal Article
Open access
PDF file
CSCarmen Sánchez
Carmen Sánchez
MMMauro Malve
Mauro Malve
Cristina DíazCristina Díaz
Cristina Díaz
Fused deposition modeling (FDM) is an additive manufacturing (AM) technology that enables the fabrication of complex and patient-specific devices made of biodegradable polymers. The successful implementation of the process requires exhaustive control of the workflow, focusing on material selection, device design, and manufacturing parameters. The aim of this study is to evaluate and compare the printability, processability, and mechanical performance of a polymer blend for the fabrication of customized airway stents using FDM printing, with a focus on its potential industrial scalability. Two FDM manufacturing approaches were evaluated using standard geometries to manufacture a blend of biodegradable polymers, using either filaments or pellets as feedstock. Moreover, the suitability of a blend made of polycaprolactone (PCL) and polydioxanone (PDO) for manufacturing tracheal stents was studied in comparison to their pure forms. Regarding the manufacturing technology, the feeding method itself was not the primary factor affecting the mechanical properties of the printed components, which was directly related to the geometry of the device and the cooling time polymers required. Furthermore, although the PCL/PDO blend showed a slightly higher mean elastic modulus than pure PCL, the resulting material did not exhibit sufficient radial resistance for airway stent applications. The design and development of 3D-printed medical devices require an evaluation of the entire manufacturing workflow. Device geometry and material selection are strongly influenced by the manufacturing technology selected and have a direct impact on the mechanical performance of the final product.