Carolina Vicente

Prof. Carolina Vicente

Polytechnic Institute of Coimbra, Coimbra, Portugal
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2023 in Chemosphere
Verified
Journal Article
Open access
CVCarolina Vicente
Carolina Vicente
JSJoão Rafael Silva
João Rafael Silva
Andreia Duarte SantosAndreia Duarte Santos
Andreia Duarte Santos
JSJoão F. Silva
João F. Silva
JMJorge T. Mano
Jorge T. Mano
LCLuis M. Castro
Luis M. Castro
Electrocoagulation was investigated as a method for treating wastewater containing polyvinyl acetate (PVAc) from the furniture industry. The study evaluated the evolution of iron concentration and passivation during the treatment process. Laboratory-scale experiments were conducted to evaluate the effects of inter-electrode distance (d), current density, and mode on treatment performance. Three values of d (0.3, 0.6, and 0.9 cm) were studied and found to have no significant effect on performance. However, lower d values resulted in reduced energy consumption due to a decrease in applied voltage. Three values of current density (132, 158, and 197 A m-2) were studied under two current modes, Direct Current (DC) and Alternating Pulsed Current (APC). The best treatment performance for DC occurred under 158 A m-2 (the treated wastewater was characterized by pH = 4.59 ± 0.02, conductivity = 996 ± 21 μS cm-1, COD = 1940 ± 55 mgO2 L-1, TSS = 105 ± 14 mg L-1, and Fe = 50.39 ± 1.87 mgFe L-1). For APC, the best performance was achieved under 197 A m-2 (the treated wastewater was characterized by pH = 6.33 ± 0.06, conductivity = 988 ± 17 μS cm-1, COD = 1942 ± 312 mgO2 L-1, TSS = 199 ± 55 mg L-1, and Fe = 44.68 ± 4.60 mgFe L-1). Despite the promising results, treatment performance was insufficient to meet the legal requirements for water discharge. APC was found to be a more economically viable approach, as it reduced anode wear, electrode passivation, and energy consumption. The quantity of iron released increased with d, and the effect of current density on iron concentration was found to be non-linear. However, applying APC reduced the iron content for all tested current densities. The tests showed that EC was effective in removing chemical oxygen demand (COD) and total suspended solids (TSS), achieving removal efficiencies above 92% and 99%, respectively. However, the studied treatment procedures were insufficient to meet the EU legal requirements for water discharge. Therefore, the obtained wastewater should undergo a post-treatment process.

10 March 2023 in Water
Verified
Journal Article
Open access
PDF file
JSJoão F. Silva
João F. Silva
JSJoão Rafael Silva
João Rafael Silva
Andreia Duarte SantosAndreia Duarte Santos
Andreia Duarte Santos
CVCarolina Vicente
Carolina Vicente
JDJan Dries
Jan Dries
LCLuis M. Castro
Luis M. Castro
The authors conducted a study on treating synthetic dairy wastewater using aerobic granular sludge (AGS) in a laboratory-scale continuous flow reactor (CFR) system. The system consisted of an anaerobic reactor, an aerobic reactor, and a settling sedimentation tank, with different hydraulic retention times tested over a 90-day period. The study monitored sludge characteristics and effluent treatment performance and found that the system achieved excellent removal rates for chemical oxygen demand and total carbon, exceeding 90%. As a result, the effluent met Portuguese laws for direct release into the water environment. Moreover, the study found that the AGS system improved the sludge sedimentation capacity from 272 to 80 mL/g, demonstrating its effectiveness as a viable treatment alternative for this type of effluent.

22 March 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
CVCarolina Vicente
Carolina Vicente
JSJoão Rafael Silva
João Rafael Silva
Andreia Duarte SantosAndreia Duarte Santos
Andreia Duarte Santos
Rosa M. Quinta-FerreiraRosa M. Quinta-Ferreira
Rosa M. Quinta-Ferreira
LCLuis M. Castro
Luis M. Castro
Cork boiling wastewater (CBW) is a highly polluted and difficult to treat effluent resultant from the cork manufacturing industry. This study aims to evaluate a new, reliable, efficient, and sustainable process to treat this effluent. This paper tested electrocoagulation as a pre- and post-treatment to improve the already existing physicochemical treatment in a cork production facility in Portugal. In the physicochemical procedures (PC), the addition of different volumes of coagulant (ferric chloride (III) 40% w/w), neutralizer (sodium hydroxide, 32% w/w), and flocculant (polyacrylamide, 0.2 g/L) were evaluated. Electrocoagulation (EC) was performed in a bench-scale reactor, using aluminum and stainless-steel electrodes. For EC, different initial pH, current density, and current tension values were tested. When electrocoagulation was used as a post-treatment, better performances were achieved. However, treatment costs were increased significantly. Coagulation/flocculation offers a viable and cheap treatment, achieving removal efficiencies of 88.2%, 81.0%, 76.9%, and 94.2% for total chemical oxygen demand (tCOD), total carbon (TC), total nitrogen (TN), and soluble chemical oxygen demand (sCOD), respectively. With a PC-EC combination, it is possible to achieve removal efficiencies of 92.4%, 88.0%, 91.4%, and 91.4% for tCOD, TC, TN, and sCOD, respectively. The increased TN removal efficiency can translate into great benefits for certain discharge conditions and should be taken into consideration for improving the sustainability of cork industry. On the other hand, when EC is used as a pre-treatment, there are no benefits either in terms of treatment performance or operating costs.

2 December 2023
Verified
Book Chapter
Closed access
PDF file
CVCarolina Vicente
Carolina Vicente
DADânia S. Ascenção
Dânia S. Ascenção
JSJoão Rafael Silva
João Rafael Silva
LCLuis M. Castro
Luis M. Castro

22 December 2025 in Environments
Verified
Journal Article
Open access
PDF file
CVCarolina Vicente
Carolina Vicente
SGSara Gonçalves
Sara Gonçalves
Carla Alexandra GamelasCarla Alexandra Gamelas
Carla Alexandra Gamelas
SASusana Marta Almeida
Susana Marta Almeida
Nuno CanhaNuno Canha
Nuno Canha
The oxidative potential (OP) of airborne particulate matter (PM) has emerged as a promising metric to assess the capacity of particles to induce oxidative stress and related health effects. Thus, ensuring the reliability and comparability of OP measurements is essential for accurate environmental and toxicological assessment. This study aimed to develop and evaluate a quality control approach for the dithiothreitol (DTT) assay used in OP determination. The DTT assay provides an estimation on how harmful PM can be to human health through oxidative stress, relating it to the consumption of DTT during the test period. Two experiments were conducted using the Standard Reference Material (SRM) 1648–Urban Particulate Matter (NIST, USA). The first assessed the effect of trichloroacetic acid (TCA) addition order and the feasibility of using SRM 1648 as a reference material. The second evaluated the stability of the SRM solution over a 63-day period. Statistical analysis (Mann–Whitney test) indicated that the order of TCA addition did not significantly affect OP values (p > 0.05). SRM 1648 solution determination showed high reproducibility (mean DTTₘ = 14.6 ± 2.4 pmol·min−1·µg−1), although a gradual increase in DTT metrics was observed over time, consistent with progressive dissolution. The results support the application of SRM 1648 as a reference material for DTT assay quality control, supporting methodological harmonization in OP determination, provided that a freshly prepared solution is used.