Francisco Carrillo

Dr. Francisco Carrillo

University of Seville, Seville, Spain
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in International Journal of Biological Macromolecules
Verified
Journal Article
Closed access
Jenifer SantosJenifer Santos
Jenifer Santos
MAM.A. Alcaide-González
M.A. Alcaide-González
LTL.A. Trujillo-Cayado
L.A. Trujillo-Cayado
FCFrancisco Carrillo
Francisco Carrillo
MAM.C. Alfaro-Rodríguez
M.C. Alfaro-Rodríguez

1 April 2015 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
LPLuis M. Pérez-Mosqueda
Luis M. Pérez-Mosqueda
Luis Alfonso Trujillo-CayadoLuis Alfonso Trujillo-Cayado
Luis Alfonso Trujillo-Cayado
FCFrancisco Carrillo
Francisco Carrillo
PAPablo Ramírez del Amo
Pablo Ramírez del Amo
José MuñozJosé Muñoz
José Muñoz

28 May 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Jenifer SantosJenifer Santos
Jenifer Santos
Luis Alfonso Trujillo-CayadoLuis Alfonso Trujillo-Cayado
Luis Alfonso Trujillo-Cayado
FCFrancisco Carrillo
Francisco Carrillo
MLMª Luisa López-Castejón
Mª Luisa López-Castejón
MAMaría-Carmen Alfaro-Rodríguez
María-Carmen Alfaro-Rodríguez
Zein, a subproduct of the food industry and a protein, possesses limited applications due to its high hydrophobic character. The objective of this research was to investigate the influence of homogenization pressure and cycles on the volumetric mean diameter (D4,3), span values, and Turbiscan Stability Index (TSI) using the response surface methodology for microfluidized emulsions containing zein as a unique stabilizer. Results showed that homogenization pressure seems to be the most influential parameter to obtain enhanced physical stability and droplet size distributions, with the optimum being 20,000 psi. Interestingly, the optimum number of cycles for volumetric diameter, span value, and TSI is not the same. Although a decrease of D4,3 with number of cycles is observed (optimum three cycles), this provokes an increase of span values (optimum one cycle) due to the recoalescence effect. Since physical stability is influenced by D4,3 and span, the minimum for TSI is observed at the middle level of the cycles (2 cycles). This work highlights that not only volumetric diameter, but also span value must be taken into consideration in order to obtain stable zein emulsions. In addition, this study wants to extend the limited knowledge about zein-based emulsions processed with a Microfluidizer device.

1 May 2000 in Chemical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
FCFrancisco Carrillo
Francisco Carrillo
AMA. Martín
A. Martín
ARA. Roselló
A. Roselló

1 January 2018 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
RLR. Llinares
R. Llinares
PAPablo Ramírez del Amo
Pablo Ramírez del Amo
JCJ. Carmona
J. Carmona
FCFrancisco Carrillo
Francisco Carrillo
JMJ. Munñoz
J. Munñoz

16 January 2025 in International Journal of Biological Macromolecules
Verified
Journal Article
Open access
ACAna Castillejo
Ana Castillejo
Guillermo Martínez MuñozGuillermo Martínez Muñoz
Guillermo Martínez Muñoz
Ernesto J. Delgado-PujolErnesto J. Delgado-Pujol
Ernesto J. Delgado-Pujol
EVEduardo Villalobo
Eduardo Villalobo
FCFrancisco Carrillo
Francisco Carrillo
AAANA ALCUDIA
ANA ALCUDIA
Titanium is widely used for implants however it presents limitations such as infection risk, stress shielding phenomenon, and poor osseointegration. To address these issues, a novel approach was proposed that involves fabricating porous titanium substrates, to reduce implant stiffness, minimizing stress shielding and bone resorption, and applying polymeric coatings to improve bioactivity. Composite coating prepared from chitosan, silver nanoparticles, and nanohydroxyapatite was optimized to enhance antibacterial properties and promote osseointegration. Chitosan with 80.5 % of deacetylation degree was used to prepare composites with diverse compositions, including different methodologies of adding silver nanoparticles, with silver concentrations below toxic level. Antibacterial activity was tested with three different strains, including Gram+ and Gram- bacteria, demonstrating excellent inhibition after 21 days. In addition, the induction of hydroxyapatite formation was investigated. Finally, the optimal porous metallic substrate that exhibited a more suitable stiffness (29 GPa) (close to the cortical bone tissue they intend to replace) was chosen to be infiltrated with the selected composites. In summary, this synergistic approach based on the combination of porous titanium substrates with 60 vol% porosity and a 355-500 μm pore size distribution coated with 3%CS-nHA-AgNPs-TPP-AgNPsbath composite provided a potential solution to provide implants with improved biomechanical balance and biofunctionality.