Cátia Loureiro

Ms. Cátia Loureiro

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2023 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
APAna Inês Pereira
Ana Inês Pereira
PFPedro Franco-Gonçalo
Pedro Franco-Gonçalo
PLPedro Leite
Pedro Leite
ARAlexandrine Ribeiro
Alexandrine Ribeiro
Sofia Alves-PimentaSofia Alves-Pimenta
Sofia Alves-Pimenta
MGMário Ginja
Mário Ginja
Artificial intelligence and machine learning have been increasingly used in the medical imaging field in the past few years. The evaluation of medical images is very subjective and complex, and therefore the application of artificial intelligence and deep learning methods to automatize the analysis process would be very beneficial. A lot of researchers have been applying these methods to image analysis diagnosis, developing software capable of assisting veterinary doctors or radiologists in their daily practice. This article details the main methodologies used to develop software applications on machine learning and how veterinarians with an interest in this field can benefit from such methodologies. The main goal of this study is to offer veterinary professionals a simple guide to enable them to understand the basics of artificial intelligence and machine learning and the concepts such as deep learning, convolutional neural networks, transfer learning, and the performance evaluation method. The language is adapted for medical technicians, and the work already published in this field is reviewed for application in the imaging diagnosis of different animal body systems: musculoskeletal, thoracic, nervous, and abdominal.

27 August 2024 in Multimedia Tools and Applications
Verified
Journal Article
Open access
PDF file
CLCátia Loureiro
Cátia Loureiro
LGLio Gonçalves
Lio Gonçalves
PLPedro Leite
Pedro Leite
PFPedro Franco-Gonçalo
Pedro Franco-Gonçalo
APAna Inês Pereira
Ana Inês Pereira
Vítor Jesus FilipeVítor Jesus Filipe
Vítor Jesus Filipe
Radiographic canine hip dysplasia (CHD) diagnosis is crucial for breeding selection and disease management, delaying progression and alleviating the associated pain. Radiography is the primary imaging modality for CHD diagnosis, and visual assessment of radiographic features is sometimes used for accurate diagnosis. Specifically, alterations in femoral neck shape are crucial radiographic signs, with existing literature suggesting that dysplastic hips have a greater femoral neck thickness (FNT). In this study we aimed to develop a three-stage deep learning-based system that can automatically identify and quantify a femoral neck thickness index (FNTi) as a key metric to improve CHD diagnosis. Our system trained a keypoint detection model and a segmentation model to determine landmark and boundary coordinates of the femur and acetabulum, respectively. We then executed a series of mathematical operations to calculate the FNTi. The keypoint detection model achieved a mean absolute error (MAE) of 0.013 during training, while the femur segmentation results achieved a dice score (DS) of 0.978. Our three-stage deep learning-based system achieved an intraclass correlation coefficient of 0.86 (95% confidence interval) and showed no significant differences in paired t-test compared to a specialist (p > 0.05). As far as we know, this is the initial study to thoroughly measure FNTi by applying computer vision and deep learning-based approaches, which can provide reliable support in CHD diagnosis.

12 January 2026 in IEEE Access
Verified
Journal Article
Open access
CLCátia Loureiro
Cátia Loureiro
SDSandra Dixe
Sandra Dixe
CNCristiana Neto
Cristiana Neto
ASAntónio Silva
António Silva
BMBeatriz Miranda
Beatriz Miranda
Duarte FernandesDuarte Fernandes
Duarte Fernandes
The growing urbanization of modern societies intensifies the demand for sustainable mobility that aligns efficiency, safety, and environmental responsibility in smart cities. Shared vehicle systems address this need, but remain limited by subjective manual inspections that hinder operational efficiency. Automated exterior damage assessment via computer vision offers a scalable alternative, although its success critically depends on high-quality, domain-specific datasets, which remain scarce. To overcome this limitation, we introduce SYNDCAR (SYNthetic Damage CAR dataset), a generative AI-based dataset that simulates realistic vehicle damage in images with precise annotations for detection and vehicle parts segmentation. Extensive experiments were conducted that covered hyperparameter tuning, transfer learning, benchmarking of CNN- and Transformer-based models, and post-training optimization and quantization. The results highlight the challenges of damage detection due to appearance variability and dataset size, while pointing to practical solutions: YOLOv8-X achieved the highest accuracy, whereas YOLOv12-S provided the best trade-off. TensorRT deployment tests (FP16/INT8) further reduced the inference time by ≈ 71% on the GPU and the energy consumption by 65%. Segmentation remained more energy-intensive than detection. In general, SYNDCAR demonstrates the potential of synthetic datasets to enable accurate, efficient, and scalable vehicle inspection systems.

27 March 2026 in IEEE Access
Verified
Journal Article
Open access
SDSandra Dixe
Sandra Dixe
CLCátia Loureiro
Cátia Loureiro
BMBeatriz Miranda
Beatriz Miranda
ASAntónio Silva
António Silva
LCLuís De Azevedo Cura
Luís De Azevedo Cura
Duarte FernandesDuarte Fernandes
Duarte Fernandes
This paper presents a dual-mode sentinel surveillance architecture for shared vehicles that combines low-power inertial event triggering with low-rate fisheye vision and temporal decision logic. Unlike conventional sentry systems based on continuous vision or motion-only alarms, the proposed approach prioritizes energy efficiency while preserving contextual awareness. We introduce SentinelCAR, a real-world fisheye dataset comprising 18308 images annotated for activity-aware human presence around parked vehicles. A comprehensive benchmark of state-of-the-art detectors (YOLOv8-v12 and RT-DETR variants) shows that YOLOv11m provides the best accuracy-efficiency trade-off, achieving mAP[.5:.95] ≈ 0.90. The selected model is deployed on an NVIDIA Jetson Orin Nano and evaluated under multiple backends and precision formats (FP32, FP16, INT8). Experimental results demonstrate real-time performance of up to 70.4 FPS with (0.92-0.94) J per inference under TensorRT INT8 execution. In addition, an onboard post-processing pipeline based on spatial masking, motion consistency, false-positive suppression zones, and temporal hysteresis significantly improves state stability by reducing spurious activations caused by reflections and static background elements. These results provide a practical foundation for energy-aware, privacy-preserving sentinel surveillance in shared mobility scenarios.

1 January 2022
Verified
Book Chapter
Closed access
PDF file
CLCátia Loureiro
Cátia Loureiro
Vítor Jesus FilipeVítor Jesus Filipe
Vítor Jesus Filipe
LGLIO GONÇALVES
LIO GONÇALVES

24 May 2023 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
PFPedro Franco-Gonçalo
Pedro Franco-Gonçalo
APAna Inês Pereira
Ana Inês Pereira
CLCátia Loureiro
Cátia Loureiro
Sofia Alves-PimentaSofia Alves-Pimenta
Sofia Alves-Pimenta
Vítor Jesus FilipeVítor Jesus Filipe
Vítor Jesus Filipe
MGMário Ginja
Mário Ginja
The alteration in the shape of the femoral neck is an important radiographic sign for scoring canine hip dysplasia (CHD). Previous studies have reported that the femoral neck thickness (FNT) is greater in dogs with hip joint dysplasia, becoming progressively thicker with disease severity. The main objective of this work was to describe a femoral neck thickness index (FNTi) to quantify FNT and to study its association with the degree of CHD using the Fédération Cynologique Internationale (FCI) scheme. A total of 53 dogs (106 hips) were randomly selected for this study. Two examiners performed FNTi estimation to study intra- and inter-examiner reliability and agreement. The paired t-test, the Bland-Altman plots, and the intraclass correlation coefficient showed excellent agreement and reliability between the measurements of the two examiners and the examiners’ sessions. All joints were scored in five categories by an experienced examiner according to FCI criteria. The results from examiner 1 were compared between FCI categories. Hips that were assigned an FCI grade of A (n = 19), B (n = 23), C (n = 24), D (n = 24), and E (n = 16) had a mean ± standard deviation FNTi of 0.809 ± 0.024, 0.835 ± 0.044, 0.868 ± 0.022, 0.903 ± 0.033, and 0.923 ± 0.068, respectively (ANOVA, p < 0.05). Therefore, these results show that FNTi is a parameter capable of evaluating proximal femur bone modeling and that it has the potential to enrich conventional CHD scoring criteria if incorporated into a computer-aided diagnosis capable of detecting CHD.