Carlos Cano-Espinosa

Dr. Carlos Cano-Espinosa

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2018
Verified
Conference Paper
Closed access
PDF file
GGGerman Gonzalez-Serrano
German Gonzalez-Serrano
GWGeorge R. Washko
George R. Washko
RERaúl San José Estépar
Raúl San José Estépar
Miguel CazorlaMiguel Cazorla
Miguel Cazorla
Carlos Cano-EspinosaCarlos Cano-Espinosa
Carlos Cano-Espinosa
Introduction: The Agatston score is a well-established metric of cardiovascular disease related to clinical outcomes. It is computed from CT scans by a) measuring the volume and intensity of the atherosclerotic plaques and b) aggregating such information in an index. Objective: To generate a convolutional neural network that inputs a non-contrast chest CT scan and outputs the Agatston score associated with it directly, without a prior segmentation of Coronary Artery Calcifications (CAC). Materials and methods: We use a database of 5973 non-contrast non-ECG gated chest CT scans where the Agatston score has been manually computed. The heart of each scan is cropped automatically using an object detector. The database is split in 4973 cases for training and 1000 for testing. We train a 3D deep convolutional neural network to regress the Agatston score directly from the extracted hearts. Results: The proposed method yields a Pearson correlation coefficient of r = 0.93; p ≤ 0.0001 against manual reference standard in the 1000 test cases. It further stratifies correctly 72.6% of the cases with respect to standard risk groups. This compares to more complex state-of-the-art methods based on prior segmentations of the CACs, which achieve r = 0.94 in ECG-gated pulmonary CT. Conclusions: A convolutional neural network can regress the Agatston score from the image of the heart directly, without a prior segmentation of the CACs. This is a new and simpler paradigm in the Agatston score computation that yields similar results to the state-of-the-art literature.

24 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Carlos Cano-EspinosaCarlos Cano-Espinosa
Carlos Cano-Espinosa
Miguel CazorlaMiguel Cazorla
Miguel Cazorla
GGGerman Gonzalez-Serrano
German Gonzalez-Serrano
Pulmonary Embolism (PE) is a respiratory disease caused by blood clots lodged in the pulmonary arteries, blocking perfusion, limiting blood oxygenation, and inducing a higher load on the right ventricle. Pulmonary embolism is diagnosed using contrast enhanced Computed Tomography Pulmonary Angiography (CTPA), resulting in a 3 D image where the pulmonary arteries appear as bright structures, and emboli appear as filling defects, with these often being difficult to see, especially in the subsegmental case. In comparison to an expert panel, the average radiologist has a sensitivity of between 77% and 94 % . Computer Aided Detection (CAD) is regarded as a promising system to detect emboli, but current algorithms are hindered by a high false positive rate. In this paper, we propose a novel methodology for emboli detection. Instead of finding candidate points and characterizing them, we find emboli directly on the whole image slice. Detections across different slices are merged into a single detection volume that is post-processed to generate emboli detections. The system was evaluated on a public PE database of 80 scans. On 20 test scans, our system obtained a per-embolus sensitivity of 68% at a regime of one false positive per scan, improving on state-of-the-art methods. We therefore conclude that our multi-slice emboli segmentation CAD for PE method is a valuable alternative to the standard methods of candidate point selection and classification.

9 January 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
Carlos Cano-EspinosaCarlos Cano-Espinosa
Carlos Cano-Espinosa
GGGerman Gonzalez-Serrano
German Gonzalez-Serrano
GWGeorge R. Washko
George R. Washko
Miguel CazorlaMiguel Cazorla
Miguel Cazorla
RERaul San Jose Estepar
Raul San Jose Estepar
Biomarker estimation methods from medical images have traditionally followed a segment-and-measure strategy. Deep-learning regression networks have changed such a paradigm, enabling the direct estimation of biomarkers in databases where segmentation masks are not present. While such methods achieve high performance, they operate as a black-box. In this work, we present a novel deep learning network structure that, when trained with only the value of the biomarker, can perform biomarker regression and the generation of an accurate localization mask simultaneously, thus enabling a qualitative assessment of the image locus that relates to the quantitative result. We showcase the proposed method with three different network structures and compare their performance against direct regression networks in four different problems: pectoralis muscle area (PMA), subcutaneous fat area (SFA), liver mass area in single slice computed tomography (CT), and Agatston score estimated from non-contrast thoracic CT images (CAC). Our results show that the proposed method improves the performance with respect to direct biomarker regression methods (correlation coefficient of 0.978, 0.998, and 0.950 for the proposed method in comparison to 0.971, 0.982, and 0.936 for the reference regression methods on PMA, SFA and CAC respectively) while achieving good localization (DICE coefficients of 0.875, 0.914 for PMA and SFA respectively, p <; 0.05 for all pairs). We observe the same improvement in regression results comparing the proposed method with those obtained by quantify the outputs using an U-Net segmentation network (0.989 and 0.951 respectively). We, therefore, conclude that it is possible to obtain simultaneously good biomarker regression and localization when training biomarker regression networks using only the biomarker value.

12 September 2018
Verified
Book Chapter
Closed access
PDF file
Carlos Cano-EspinosaCarlos Cano-Espinosa
Carlos Cano-Espinosa
GGGerman Gonzalez-Serrano
German Gonzalez-Serrano
GWGeorge R. Washko
George R. Washko
Miguel CazorlaMiguel Cazorla
Miguel Cazorla
RERaúl San José Estépar
Raúl San José Estépar

11 July 2019 in IEEE International Symposium on Biomedical Imaging
Verified
Conference Paper
Closed access
Carlos Cano-EspinosaCarlos Cano-Espinosa
Carlos Cano-Espinosa
GGGerman Gonzalez
German Gonzalez
GWGeorge R. Washko
George R. Washko
MCMiguel Cazorlaa
Miguel Cazorlaa
RERaul San Jose Estepar
Raul San Jose Estepar
Biomarker inference from biomedical images is one of the main tasks of medical image analysis. Standard techniques follow a segmentation-and-measure strategy, where the structure is first segmented and then the measurement is performed. Recent work has shown that such strategy could be replaced by a direct regression of the biomarker value in using regression networks. While achieving high correlation coefficients, such techniques operate as a 'black-box', not offering quality-control images. We present a methodology to regress the biomarker from the image while simultaneously computing the quality control image. Our proposed methodology does not require segmentation masks for training, but infers the segmentations directly from the pixels that used to compute the biomarker value. The network proposed consists of two steps: a segmentation method to an unknown reference and a summation method for the biomarker estimation. The network is optimized using a dual loss function, L2 for the biomarkers and an L1 to enforce sparsity. We showcase our methodology in the problem of pectoralis muscle area (PMA) and subcutaneous fat area (SFA) inference in a single slice from chest-CT images. We use a database of 7000 cases to which only the value of the biomarker is known for training and a test set of 3000 cases with both, biomarkers and segmentations. We achieve a correlation coefficient of 0.97 for PMA and 0.98 for SFA with respect to the reference standard. The average DICE coefficient is of 0.88 (PMA) and 0.89 (SFA). Comparing with standard segment-and-measure techniques, we achieve the same correlation for the biomarkers but smaller DICE coefficients in segmentation. Such is of little surprise, since segmentation networks are the upper limit of performance achievable, and we are not using segmentation masks for training. We can conclude that it is possible to infer segmentation masks from biomarker regression networks.

1 March 2026 in INTED Proceedings
Verified
Conference Paper
Closed access
PDF file
Carlos QuesadaCarlos Quesada
Carlos Quesada
Carlos Cano-EspinosaCarlos Cano-Espinosa
Carlos Cano-Espinosa
DVDiego Viejo-Hernando
Diego Viejo-Hernando
GRGabriel Mora Rodriguez
Gabriel Mora Rodriguez
ASAlberto Joaquín Lopez Sellers
Alberto Joaquín Lopez Sellers