Chiara Catalano

Mrs. Chiara Catalano

University of Palermo, Palermo, Sicilia, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CCChiara Catalano
Chiara Catalano
VAValentina Agnese
Valentina Agnese
GGGiovanni Gentile
Giovanni Gentile
GRGiuseppe Raffa
Giuseppe Raffa
MPMichele Pilato
Michele Pilato
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Atlas-based analyses of patients with cardiovascular diseases have recently been explored to understand the mechanistic link between shape and pathophysiology. The construction of probabilistic atlases is based on statistical shape modeling (SSM) to assess key anatomic features for a given patient population. Such an approach is relevant to study the complex nature of the ascending thoracic aortic aneurysm (ATAA) as characterized by different patterns of aortic shapes and valve phenotypes. This study was carried out to develop an SSM of the dilated aorta with both bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV), and then assess the computational hemodynamic of virtual models obtained by the deformation of the mean template for specific shape boundaries (i.e., ±1.5 standard deviation, σ). Simulations demonstrated remarkable changes in the velocity streamlines, blood pressure, and fluid shear stress with the principal shape modes such as the aortic size (Mode 1), vessel tortuosity (Mode 2), and aortic valve morphologies (Mode 3). The atlas-based disease assessment can represent a powerful tool to reveal important insights on ATAA-derived hemodynamic, especially for aneurysms which are considered to have borderline anatomies, and thus challenging decision-making. The utilization of SSMs for creating probabilistic patient cohorts can facilitate the understanding of the heterogenous nature of the dilated ascending aorta.

25 September 2025 in APL Bioengineering
Verified
Journal Article
Open access
CCChiara Catalano
Chiara Catalano
RSRoberta Scuoppo
Roberta Scuoppo
TTTahir Turgut
Tahir Turgut
VBVincent Bouwman
Vincent Bouwman
NGNils Götzen
Nils Götzen
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Transcatheter aortic valve implantation (TAVI) has become a standardized treatment for aortic valve stenosis, supported by computational modeling to enhance procedural planning. However, the credibility of TAVI simulations requires rigorous validation following regulatory standards. This study aims to perform a population-based validation of the structural and hemodynamic simulation performance of the SAPIEN 3 (S3) Ultra device by comparing computational predictions with clinical post-TAVI data, following the ASME V&V 40 framework. A patient-specific structural model followed by fluid–structure interaction was developed to simulate S3 deployment and then assess post-TAVI hemodynamics in 20 patients. Structural parameters (device diameters) and hemodynamic indices (effective orifice area, EOA, and transmural pressure gradient, TPG) were extracted. Validation was performed using empirical cumulative distribution function (ECDF) analysis, with an acceptance threshold of 5% for model credibility. EOA and TPG predictions showed reasonable agreement with echocardiographic data (errors within 10%). ECDF-based comparison demonstrated a high level of accuracy for device diameters (≤5% area metric), whereas hemodynamic parameters exhibited slightly greater discrepancies, potentially due to clinical measurement variability. This study establishes a robust computational validation framework for patient-specific TAVI modeling, ensuring regulatory compliance and clinical applicability. These findings highlight the potential of in silico trials to support TAVI planning and decision-making. This study is complemented by a second part dedicated to uncertainty quantification and sensitivity analysis.

25 September 2025 in APL Bioengineering
Verified
Journal Article
Open access
RSRoberta Scuoppo
Roberta Scuoppo
CCChiara Catalano
Chiara Catalano
TTTahir Turgut
Tahir Turgut
NGNils Götzen
Nils Götzen
SCStefano Cannata
Stefano Cannata
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Transcatheter aortic valve implantation (TAVI) benefits from patient-specific computational modeling, yet model credibility remains a challenge. The ASME V&V40 standard provides a framework for assessing uncertainty and sensitivity in in silico predictions, ensuring reliability in clinical decision-making. This study evaluates uncertainty quantification (UQ) and sensitivity analysis of a patient-specific TAVI model using the ASME V&V40 standard to enhance model credibility. Four patient-specific TAVI models with 23 and 26 mm SAPIEN 3 Ultra (S3) devices were developed using finite-element simulations for deployment and fluid–structure interaction analysis for hemodynamic analysis. Uncertain parameters included anatomical features, material properties, hemodynamic conditions, and procedural variables. A surrogate model was constructed with Gaussian-process regression, and probabilistic assessment was conducted via quasi-Monte Carlo analysis. Sensitivity analysis identified key parameters influencing model outputs. The surrogate model accurately predicted device diameter (mean relative error <1%), with balloon expansion volume and stent-frame material properties being the most influential. Hemodynamic predictions exhibited greater uncertainty, with effective orifice area and pressure gradient showing deviations beyond the 5% validation threshold. This study establishes a framework for UQ in patient-specific TAVI modeling, demonstrating reliable device deployment predictions. The findings support integrating in silico models into clinical decision-making, benefiting clinicians, manufacturers, and regulatory bodies. This study is complemented by a first part dedicated to the discrete validation of the patient-specific TAVI model against clinical data.

7 March 2022 in Prosthesis
Verified
Journal Article
Open access
PDF file
CCChiara Catalano
Chiara Catalano
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Transcatheter aortic valve replacement (TAVR) has become a milestone for the management of aortic stenosis in a growing number of patients who are unfavorable candidates for surgery. With the new generation of transcatheter heart valves (THV), the feasibility of transcatheter mitral valve replacement (TMVR) for degenerated mitral bioprostheses and failed annuloplasty rings has been demonstrated. In this setting, computational simulations are modernizing the preoperative planning of transcatheter heart valve interventions by predicting the outcome of the bioprosthesis interaction with the human host in a patient-specific fashion. However, computational modeling needs to carry out increasingly challenging levels including the verification and validation to obtain accurate and realistic predictions. This review aims to provide an overall assessment of the recent advances in computational modeling for TAVR and TMVR as well as gaps in the knowledge limiting model credibility and reliability.

5 January 2026 in Computers in Biology and Medicine
Verified
Journal Article
Open access
LCLuca Crugnola
Luca Crugnola
CCChiara Catalano
Chiara Catalano
Laura FusiniLaura Fusini
Laura Fusini
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Gianluca PontoneGianluca Pontone
Gianluca Pontone
CVChristian Vergara
Christian Vergara
Introduced as an alternative to open-heart surgery for elderly patients, Transcatheter Aortic Valve Implantation (TAVI) has recently been extended to younger patients due to comparable performance with the gold-standard. However, the long-term durability of the bio-prosthetic TAVI valves is limited by Structural Valve Deterioration (SVD), an inevitable degenerative process whose pathogenesis is still unclear. In this study, we aim to computationally investigate a possible relationship between aortic hemodynamics and SVD development. To this aim, we collect data from twelve patients with and without SVD at long-term follow-up exams. Starting from pre-operative clinical images, we build early post-operative virtual geometries and perform Computational Fluid Dynamics simulations by prescribing a personalized flow rate based on Echo Doppler data. In order to identify a premature onset of SVD, we propose three computational hemodynamic indices: Wall Damage Index (WDI), Leaflet Delamination Index (LDI), and Leaflet Permeability Index (LPI). Additionally, to each index we associate a score and, using the Wilcoxon rank-sum test, we find that each score individually shows a statistically greater median value in the SVD sub-population (WDI: p=0.008, LDI: p=0.001, LPI: p=0.020). Finally, we define a synthetic scoring system that clearly separates between SVD and non-SVD patients. Our results suggest that aortic hemodynamics may drive a premature onset of SVD, and the synthetic score could potentially assist clinicians in a patient-specific planning of follow-up exams to closely monitor those patients at high SVD risk.

19 November 2024 in Biomechanics
Verified
Journal Article
Open access
PDF file
RSRoberta Scuoppo
Roberta Scuoppo
CCChiara Catalano
Chiara Catalano
ECEleonora Costagliola
Eleonora Costagliola
SCStefano Cannata
Stefano Cannata
Salvatore PastaSalvatore Pasta
Salvatore Pasta
CGCaterina Gandolfo
Caterina Gandolfo
Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for patients with aortic stenosis (AS) at high surgical risk. However, TAVR is challenging in patients with a pre-existing mitral valve prosthesis, such as a transcatheter mitral valve replacement (TMVR), due to the likelihood of device interference. This study explores the feasibility and safety of performing TAVR in a patient with a pre-existing TMVR procedure using 3D printing, augmented reality (AR) and computational simulations to optimize preprocedural planning. Computational modeling allowed predictions of the spatial relationship between the TAVR and TMVR devices. The simulation output was therefore used as input for augmented visualization of the device interference. The 3D printing of an anatomical replica was used to physically simulate the procedure, ensuring that no significant interference would occur during heart function. The results demonstrated a safe distance of 6.4 mm between the TAVR and TMVR devices, and no functional interference was observed during simulated cardiac cycles. The use of AR in the operating room enhanced the understanding of device positioning, offering a new dimension of precision of the complex cardiovascular intervention. This study concludes that integrating AR, 3D printing, and computational simulations into preprocedural planning for high-risk structural intervention can significantly improve procedural outcomes by enhancing accuracy, safety, and operator confidence.