Salvatore Pasta

Prof. Salvatore Pasta

Department of Engineering, University of Palermo, 90128 Palermo, Italy
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2012 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
Salvatore PastaSalvatore Pasta
Salvatore Pasta
JPJulie A. Phillippi
Julie A. Phillippi
TGThomas G. Gleason
Thomas G. Gleason
David A. VorpDavid A. Vorp
David A. Vorp

1 June 2013 in Journal of Biomechanics
Verified
Journal Article
Closed access
Salvatore PastaSalvatore Pasta
Salvatore Pasta
ARAntonino Rinaudo
Antonino Rinaudo
ALAngelo Luca
Angelo Luca
MPMichele Pilato
Michele Pilato
CSCesare Scardulla
Cesare Scardulla
David A. VorpDavid A. Vorp
David A. Vorp

1 March 2009 in International Journal of Fatigue
Verified
Journal Article
Closed access
LFLivan Fratini
Livan Fratini
Salvatore PastaSalvatore Pasta
Salvatore Pasta
ARA Reynolds
A Reynolds

Verified
Journal Article
Open access
PDF file
FDFabio Distefano
Fabio Distefano
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Gabriella EpastoGabriella Epasto
Gabriella Epasto
The progress in additive manufacturing has remarkably increased the application of lattice materials in the biomedical field for the fabrication of scaffolds used as bone substitutes. Ti6Al4V alloy is widely adopted for bone implant application as it combines both biological and mechanical properties. Recent breakthroughs in biomaterials and tissue engineering have allowed the regeneration of massive bone defects, which require external intervention to be bridged. However, the repair of such critical bone defects remains a challenge. The present review collected the most significant findings in the literature of the last ten years on Ti6Al4V porous scaffolds to provide a comprehensive summary of the mechanical and morphological requirements for the osteointegration process. Particular attention was given on the effects of pore size, surface roughness and the elastic modulus on bone scaffold performances. The application of the Gibson–Ashby model allowed for a comparison of the mechanical performance of the lattice materials with that of human bone. This allows for an evaluation of the suitability of different lattice materials for biomedical applications.

1 September 2018 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
VMVincent Mendez
Vincent Mendez
MGMarzio Di Giuseppe
Marzio Di Giuseppe
Salvatore PastaSalvatore Pasta
Salvatore Pasta

5 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
LDLeonardo D'Acquisto
Leonardo D'Acquisto
RCRaffaele Colombarini
Raffaele Colombarini
Sijung HuSijung Hu
Sijung Hu
Salvatore PastaSalvatore Pasta
Salvatore Pasta
DBDiego Bellavia
Diego Bellavia
Heart rate (HR) as an important physiological indicator could properly describe global subject’s physical status. Photoplethysmographic (PPG) sensors are catching on in field of wearable sensors, combining the advantages in costs, weight and size. Nevertheless, accuracy in HR readings is unreliable specifically during physical activity. Among several identified sources that affect PPG recording, contact pressure (CP) between the PPG sensor and skin greatly influences the signals. Methods: In this study, the accuracy of HR measurements of a PPG sensor at different CP was investigated when compared with a commercial ECG-based chest strap used as a test control, with the aim of determining the optimal CP to produce a reliable signal during physical activity. Seventeen subjects were enrolled for the study to perform a physical activity at three different rates repeated at three different contact pressures of the PPG-based wristband. Results: The results show that the CP of 54 mmHg provides the most accurate outcome with a Pearson correlation coefficient ranging from 0.81 to 0.95 and a mean average percentage error ranging from 3.8% to 2.4%, based on the physical activity rate. Conclusion: Authors found that changes in the CP have greater effects on PPG-HR signal quality than those deriving from the intensity of the physical activity and specifically, the individual best CP for each subject provided reliable HR measurements even for a high intensity of physical exercise with a Bland–Altman plot within ±11 bpm. Although future studies on a larger cohort of subjects are still needed, this study could contribute a profitable indication to enhance accuracy of PPG-based wearable devices.