Juan José Choquehuanca-Zevallos

Mr. Juan José Choquehuanca-Zevallos

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2010
Verified
Conference Paper
Closed access
JCJavier Ferrer Coll
Javier Ferrer Coll
JCJuan José Choquehuanca-Zevallos
Juan José Choquehuanca-Zevallos
JCJose Chilo
Jose Chilo
PSPeter Stenumgaard
Peter Stenumgaard
Thanks to advances in digital technology many hospitals are becoming populated with wireless medical applications to control life critical functions. Electromagnetic interference can cause severe performance degradations on these wireless applications. Several accidents have been reported which calls for a more thorough characterization of these interferences in areas where critical wireless applications are used. In this paper the results of electromagnetic interference measurements performed in a hospital are presented. The amplitude probability distribution (APD) and the inter arrival pulse probability distribution (PSD) are used to characterize these environments. In addition, Middleton parameters can be calculated from the measured data. This study is considered to be a first effort to characterize the 20 MHz-2500 MHz band in hospitals.

22 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
SFSummy Farfan
Summy Farfan
JCJuan José Choquehuanca-Zevallos
Juan José Choquehuanca-Zevallos
Ana AguileraAna Aguilera
Ana Aguilera
Irvin DongoIrvin Dongo
Irvin Dongo
Yudith CardinaleYudith Cardinale
Yudith Cardinale
Continuous Sign Language Recognition is a task that involves the recognition of complete sequences of Sign Language videos and translating them into spoken or written language. This task is particularly challenging due to the complex temporal structure and variability in signing styles. In this context, temporal video segmentation emerges to distinguish individual signs from transitions in continuous video streams. Despite its importance, temporal segmentation for Sign Language has not yet fully benefited from recent advancements in Machine Learning. Many existing approaches still rely on outdated architecture. This study aims to learn the characteristics that distinguish signs from transitions, which are fundamental elements of Sign Language. To this end, we adapt two current temporal segmentation models, DiffAct and MS-TCN, and apply them to our own precisely annotated datasets for Peruvian Sign Language. We explore three training strategies—baseline, data augmentation, and multi-dataset. Results suggest that they can enhance the scores for both models but at the cost of increased variability across splits. Notably, the diffusion-based model showcased its ability to generalize to unseen sequences through higher scores for sign and transition identification on the test set, reaching a median value of 71.89% for mF1S and 72.68% for mF1B.

1 September 2018
Verified
Conference Paper
Closed access
JCJuan José Choquehuanca-Zevallos
Juan José Choquehuanca-Zevallos
FHFredy Huamán-Mamani
Fredy Huamán-Mamani
DMD.L. Mayta-Ponce
D.L. Mayta-Ponce
JLJimmy Ludeña
Jimmy Ludeña
Several properties of ceramic materials such as mechanical strength, acoustical characteristics, etc. are related to their degree of porosity. Traditional methods to estimate the porosity of materials used in construction are two slow and tedious to perform, rising the need of searching new techniques to get the degree of porosity in a fast and robust way. In this paper, a system to estimate indirectly the degree of porosity by classifying ceramic samples according the changes produced in the radio frequency response is presented. The proposal uses a patch antenna to extract relevant features that help to estimate the class of a given ceramic sample. Results show that it is possible to classify samples based on the changes of the spectral response that varies according their level of porosity since they affect the propagated waves around the antenna when they are located on the surface of the patch, and so impinges upon directly on resonance frequency and bandwidth of the antenna.

1 February 2012
Verified
Conference Paper
Closed access
COChris Kathleen Talavera Ormeno
Chris Kathleen Talavera Ormeno
MAMartha Maria Molina Alvarez
Martha Maria Molina Alvarez
JCJuan José Choquehuanca-Zevallos
Juan José Choquehuanca-Zevallos
OJOtar Javashvili
Otar Javashvili
Due to the many breakthroughs in the field of based pulse radars and ultra wide bandwidth (UWB) systems, researches of every component of those systems have been performed in recent years. As well as, in order to match the great bandwidth that pulse-based radar needs to optimally work, UWB antennas were developed for this purpose. In this paper an array based on an antipodal balanced Vivaldi antenna is studied by simulating firstly a unique Vivaldi antenna element and analyzing its return loss, gain, etc. Then a five element antenna array was built in the HFSS simulator. The gain, as it was expected, has been increased to be closed to 16 dBi and maintaining the good S11 performance of one single Vivaldi antenna.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
JCJimmy Ludeña Choez
Jimmy Ludeña Choez
JCJuan José Choquehuanca-Zevallos
Juan José Choquehuanca-Zevallos
AYAlex Yasmany-Juarez
Alex Yasmany-Juarez
EMEfraín Mayhua-López
Efraín Mayhua-López
Universidad de San AgustínUniversidad de San Agustín
Universidad de San Agustín
HPH. Saúl Pérez-Montaño
H. Saúl Pérez-Montaño
In order to increase agricultural productivity, it is necessary to manage the nutrients that the plants receive. In this sense, nitrogen is one of the most important nutrients for the adequate development and growth of plants and whose control contributes to the conservation of the environment. Traditionally, the quantification of nitrates is performed employing methods such as ion chromatography conducted in a laboratory, which leads to problems such as processing time, complexity in the analysis process itself and the need to have people trained to handle such analysis equipment. To alleviate these difficulties, some sensors use electrochemical principles; however, they present several limitations such as manufacturing complexity, cost, and difficulties in conducting real-time measurements. On the other hand, capacitive sensors have also been developed whose operating principle is based on analyzing the changes in the electrical characteristics of these devices produced by variations in the environment surrounding the sensor. For example, solutions with different concentrations of nitrates will produce an alteration of the electric field generated by the electrodes of the capacitor, producing changes in parameters such as its electrical impedance. However, the materials used to manufacture these sensors are metals, being unattractive for agricultural applications due to the corrosion they may suffer. To counteract this problem, it is possible to use other types of materials, among which graphene emerge as it has been shown to have excellent properties such as being a mechanically strong material and presenting good electrical conductivity. For this reason, in this work, the study of the sensitivity of a graphene-based interdigital capacitive sensor applied to the measurements of nitrate concentrations is performed.Different analytical methods were used. In general, the interdigital capacitive sensor shows repeatability in the measurements, especially for concentrations greater than 10 ppm with variability of 16\%. Also, parameters such as the detection limit of the sensor were calculated, the result of which was 1.71 ppm. Also, measurements were made on agricultural soil samples showing differences in readings with respect to the ion chromatography method. Differences that are attributable to the different methodologies used in the calculation of the nitrate concentration and the fertilization process that was applied to the crop field a few weeks before. Despite the difference between the sensor measurements and the results obtained by ion chromatography, both procedures showed a high amount of nitrate concentration.