Corinne Mandin

Dr. Corinne Mandin

Scientific and Technical Center for Building, Grenoble, Auvergne-Rhône-Alpes, France
orcid

Research Focus & Metrics

Academic Career Length

57Years (1970-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2019 in Indoor Air
Verified
Journal Article
Closed access
PDF file
WWWenjuan Wei
Wenjuan Wei
OROlivier Ramalho
Olivier Ramalho
LMLaeticia Malingre
Laeticia Malingre
SSSutharsini Sivanantham
Sutharsini Sivanantham
JLJohn Little
John Little
CMCorinne Mandin
Corinne Mandin

1 February 2017 in Science of The Total Environment
Verified
Journal Article
Closed access
CMCorinne Mandin
Corinne Mandin
MTMarilena Trantallidi
Marilena Trantallidi
Andrea CattaneoAndrea Cattaneo
Andrea Cattaneo
Nuno CanhaNuno Canha
Nuno Canha
VMVictor G. Mihucz
Victor G. Mihucz
JBJohn Bartzis
John Bartzis

Ioannis SakellarisIoannis Sakellaris
Ioannis Sakellaris
Dikaia SaragaDikaia Saraga
Dikaia Saraga
CMCorinne Mandin
Corinne Mandin
CRCélina Roda
Célina Roda
SFSerena Fossati
Serena Fossati
PBPhilomena Margaretha Bluyssen
Philomena Margaretha Bluyssen
Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building’s location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

7 July 2015 in Indoor Air
Verified
Journal Article
Closed access
PDF file
Nuno CanhaNuno Canha
Nuno Canha
CMCorinne Mandin
Corinne Mandin
OROlivier Ramalho
Olivier Ramalho
GWG. Wyart
G. Wyart
JRJ. Ribéron
J. Ribéron
MDM. Derbez
M. Derbez

AMAya Mansouri
Aya Mansouri
WWWenjuan Wei
Wenjuan Wei
JAJean-Marie Alessandrini
Jean-Marie Alessandrini
CMCorinne Mandin
Corinne Mandin
PBPatrice Blondeau
Patrice Blondeau
Climate change can affect the indoor environment due to heat and mass transfers between indoor and outdoor environments. To mitigate climate change impacts and adapt buildings to the changing environment, changes in building characteristics and occupants’ behavior may occur. To characterize the effects of climate change on indoor air quality (IAQ), the present review focused on four aspects: (1) experimental and modeling studies that relate IAQ to future environmental conditions, (2) evolution of indoor and outdoor air concentrations in the coming years with regard to temperature rise, (3) climate change mitigation and adaptation actions in the building sector, and (4) evolution of human behavior in the context of climate change. In the indoor environment, experimental and modeling studies on indoor air pollutants highlighted a combined effect of temperature and relative humidity on pollutant emissions from indoor sources. Five IAQ models developed for future climate data were identified in the literature. In the outdoor environment, the increasing ambient temperature may lead directly or indirectly to changes in ozone, particle, nitrogen oxides, and volatile organic compound concentrations in some regions of the world depending on the assumptions made about temperature evolution, anthropogenic emissions, and regional regulation. Infiltration into buildings of outdoor air pollutants is governed by many factors, including temperature difference between indoors and outdoors, and might increase in the years to come during summer and decrease during other seasons. On the other hand, building codes in some countries require a higher airtightness for new and retrofitted buildings. The building adaptation actions include the reinforcement of insulation, implementation of new materials and smart building technologies, and a more systematic and possibly longer use of air conditioning systems in summer compared to nowadays. Moreover, warmer winters, springs, and autumns may induce an increasing duration of open windows in these seasons, while the use of air conditioning in summer may reduce the duration of open windows.

23 September 2020 in Indoor Air
Verified
Journal Article
Closed access
PDF file
Ioannis SakellarisIoannis Sakellaris
Ioannis Sakellaris
Dikaia SaragaDikaia Saraga
Dikaia Saraga
CMCorinne Mandin
Corinne Mandin
YKYvonne Kluizenaar
Yvonne Kluizenaar
SFSerena Fossati
Serena Fossati
JBJohn G. Bartzis
John G. Bartzis