Andrea Cattaneo

Prof. Dr. Andrea Cattaneo

Department of Science and High Thechnology, University of Insubria, Como, Italy
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Science of The Total Environment
Verified
Journal Article
Closed access
CMCorinne Mandin
Corinne Mandin
MTMarilena Trantallidi
Marilena Trantallidi
Andrea CattaneoAndrea Cattaneo
Andrea Cattaneo
Nuno CanhaNuno Canha
Nuno Canha
VMVictor G. Mihucz
Victor G. Mihucz
JBJohn Bartzis
John Bartzis

1 October 2020 in Science of The Total Environment
Verified
Journal Article
Closed access
RBRamen Munir Baloch
Ramen Munir Baloch
CMCara Nichole Maesano
Cara Nichole Maesano
JCJens Christoffersen
Jens Christoffersen
SBSoutrik Banerjee
Soutrik Banerjee
Marta GabrielMarta Gabriel
Marta Gabriel
MDMarie-Christine Dewolf
Marie-Christine Dewolf

27 June 2022 in Applied Spectroscopy Reviews
Verified
Journal Article
Open access
MGMILA RÓDENAS GARCÍA
MILA RÓDENAS GARCÍA
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
Pedro BrancoPedro Branco
Pedro Branco
Francesca BorghiFrancesca Borghi
Francesca Borghi
GVGuillermo Villena
Guillermo Villena
Sofia SousaSofia Sousa
Sofia Sousa
Humans spend the majority of their time indoors, where they are potentially exposed to hazardous pollutants. Within this context, over the past few years, there has been an upsurge of low-cost sensors (LCS) for the measurement of indoor air pollutants, motivated both by recent technological advances and by increased awareness of indoor air quality (IAQ) and its potential negative health impacts. Although not meeting the performance requirements for reference regulatory-equivalent monitoring indoors, LCS can provide informative measurements, offering an opportunity for high-resolution monitoring, emission source identification, exposure mitigation and managing IAQ and energy efficiency, among others. This article discusses the strengths and limitations that LCS offer for applications in the field of IAQ monitoring; it provides an overview of existing sensor technologies and gives recommendations for different indoor applications, considering their performance in the complex indoor environment and discussing future trends.

24 August 2017 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
LPLaura Pergoli
Laura Pergoli
LCLaura Cantone
Laura Cantone
FCfavero chiara
favero chiara
LALaura Angelici
Laura Angelici
SISimona Iodice
Simona Iodice
Valentina BollatiValentina Bollati
Valentina Bollati
Exposure to particulate matter (PM) is associated with increased incidence of cardiovascular disease and increased coagulation, but the molecular mechanisms underlying these associations remain unknown. Obesity may increase susceptibility to the adverse effects of PM exposure, exacerbating the effects on cardiovascular diseases. Extracellular vesicles (EVs), which travel in body fluids and transfer microRNAs (miRNAs) between tissues, might play an important role in PM-induced cardiovascular risk. We sought to determine whether the levels of PM with an aerodynamic diameter ≤ 10 μm (PM10) are associated with changes in fibrinogen levels, EV release, and the miRNA content of EVs (EV-miRNAs), investigating 1630 overweight/obese subjects from the SPHERE Study. Short-term exposure to PM10 (Day before blood drawing) was associated with an increased release of EVs quantified by nanoparticle tracking analysis, especially EVs derived from monocyte/macrophage components (CD14+) and platelets (CD61+) which were characterized by flow cytometry. We first profiled miRNAs of 883 subjects by the QuantStudio™ 12 K Flex Real Time PCR System and the top 40 EV-miRNAs were validated through custom miRNA plates. Nine EV-miRNAs (let-7c-5p; miR-106a-5p; miR-143-3p; miR-185-5p; miR-218-5p; miR-331-3p; miR-642-5p; miR-652-3p; miR-99b-5p) were downregulated in response to PM10 exposure and exhibited putative roles in cardiovascular disease, as highlighted by integrated network analysis. PM10 exposure was significantly associated with elevated fibrinogen levels, and five of the nine downregulated EV-miRNAs were mediators between PM10 exposure and fibrinogen levels. Research on EVs opens a new path to the investigation of the adverse health effects of air pollution exposure. EVs have the potential to act both as markers of PM susceptibility and as potential molecular mechanism in the chain of events connecting PM exposure to increased coagulation, which is frequently linked to exposure and CVD development.

1 April 2017 in Building and Environment
Verified
Journal Article
Closed access
DCDavide Campagnolo
Davide Campagnolo
Dikaia SaragaDikaia Saraga
Dikaia Saraga
Andrea CattaneoAndrea Cattaneo
Andrea Cattaneo
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
CMCorinne Mandin
Corinne Mandin
JBJohn G. Bartzis
John G. Bartzis

Francesca BorghiFrancesca Borghi
Francesca Borghi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
SRSabrina Rovelli
Sabrina Rovelli
DCDavide Campagnolo
Davide Campagnolo
LBLuca Del Buono
Luca Del Buono
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
Air quality has a huge impact on different aspects of life quality, and for this reason, air quality monitoring is required by national and international regulations. Technical and procedural limitations of traditional fixed-site stations for monitoring or sampling of air pollutants are also well-known. Recently, a different type of miniaturized monitors has been developed. These monitors, due to their characteristics (e.g., low cost, small size, high portability) are becoming increasingly important for individual exposure assessment, especially since this kind of instrument can provide measurements at high spatial and temporal resolution, which is a notable advantage when approaching assessment of exposure to environmental contaminants. The aim of this study is indeed to provide information regarding current knowledge regarding the use of miniaturized air pollutant sensors. A systematic review was performed to identify original articles: a literature search was carried out using an appropriate query for the search of papers across three different databases, and the papers were selected using inclusion/exclusion criteria. The reviewed articles showed that miniaturized sensors are particularly versatile and could be applied in studies with different experimental designs, helping to provide a significant enhancement to exposure assessment, even though studies regarding their performance are still sparse.