Chi-Seng Lam

Prof. Chi-Seng Lam

University of Macau, Macao, Macao
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2016 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
TYTao Ye
Tao Ye
NDNingyi DAI
Ningyi DAI
Chi-Seng LamChi-Seng Lam
Chi-Seng Lam
MWMan-Chung Wong
Man-Chung Wong
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
The capacitive-coupling grid-connected inverter (CGCI) is coupled to the point of common coupling via a second-order LC branch. Its operational voltage is much lower than that of a conventional inductive-coupling grid-connected inverter (IGCI) when it serves as a multifunctional inverter to compensate reactive power and transfer active power simultaneously. It is a promising solution for microgrid and building-integrated distributed generator systems. A quasi-proportional-resonant (quasi-PR) controller is applied to reduce the steady-state current tracking errors of the CGCI in this paper. The quasi-PR controller generates the voltage reference for use of carrier-based pulse-width modulation, which can effectively reduce output current ripples. The second-order coupling impedance of the CGCI causes its modeling and controller design to differ from that of the conventional IGCI. A comprehensive design method for the quasi-PR controller in a CGCI is developed. The quasi-PR controller is also compared with a proportional-integration current controller. Simulation results are provided to verify the effectiveness of the quasi-PR controller and its design method in a CGCI. The current tracking errors are greatly reduced when the quasi-PR controller rather than the proportional-integration controller is applied. Experimental results are also provided to validate the CGCI as a multifunctional grid-connected inverter.

29 September 2011 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Chi-Seng LamChi-Seng Lam
Chi-Seng Lam
WCWai-Hei Choi
Wai-Hei Choi
MWMan-Chung Wong
Man-Chung Wong
YHYing-Duo Han
Ying-Duo Han
This paper presents a novel adaptive dc-link voltage-controlled LC coupling hybrid active power filter (LC-HAPF) for reducing switching loss and switching noise under reactive power compensation. First, the mathematical relationship between LC-HAPF dc-link voltage and reactive power compensation range is deduced and presented. Based on the compensation range analysis, the required minimum dc-link voltage with respect to different loading reactive power is deduced. Then, an adaptive dc-link voltage controller for the three-phase four-wire LC-HAPF is proposed, in which the dc-link voltage as well as the reactive power compensation range can be adaptively changed according to different inductive loading situations. Therefore, the compensation range, switching loss, and switching noise of the LC-HAPF can be determined and reduced correspondingly. In this paper, the reference dc-link voltage is classified into certain levels for selection in order to alleviate the problem of dc voltage fluctuation caused by its reference frequent variation, and hence reducing the fluctuation impact on the compensation performances. Finally, representative simulation and experimental results of a three-phase four-wire center-split LC -HAPF are presented to verify the validity and effectiveness of the proposed adaptive dc-link voltage-controlled LC-HAPF in dynamic reactive power compensation.

29 January 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZHZhicong Huang
Zhicong Huang
Chi-Seng LamChi-Seng Lam
Chi-Seng Lam
PMPui-In Mak
Pui-In Mak
RMRui Paulo da Silva Martins
Rui Paulo da Silva Martins
SWSiu-Chung Wong
Siu-Chung Wong
CTChi K. Tse
Chi K. Tse
This article proposes a single-stage inductive-power-transfer (IPT) converter operating as a wireless constant-power (CP) and maximum-efficiency battery charger. By maintaining a constant output power rather than providing a constant output current throughout the dominant stage of battery charging, the IPT converter can make the utmost of its power capability, thus having a faster charging rate. The proposed single-stage IPT converter adopts series-series compensation and includes a switch-controlled capacitor (SCC) and a semiactive rectifier (SAR) in the secondary side. Manipulating the SCC and the SAR to emulate the optimum impedance of the resonator and the load, we propose a novel operation approach combining the merits of load-independent transfer characteristic and load impedance matching, to achieve a simple solution to CP charging and maximum efficiency throughout the charging process. Since the control scheme is based on fixed operating frequency and secondary-side real-time regulation, wireless feedback communication is not required. Moreover, soft switching and low voltage stress can be easily achieved in this IPT converter.

1 August 2012 in IET Power Electronics
Verified
Journal Article
Closed access
Chi-Seng LamChi-Seng Lam
Chi-Seng Lam
MWM.-C. Wong
M.-C. Wong
YHY.-D. Han
Y.-D. Han
This article presents a hysteresis pulse width modulation study for a inductor-capacitor (LC)-coupling hybrid active power filter (HAPF). As the coupling LC impedance yields a non-linear inverter current slope, this can affect the controllability of using the conventional hysteresis control method and generate unexpected trigger signals to the switching devices. This results in deteriorating the system operating performances. On the basis of the proposed modelling, the linearisation of the hysteresis control for the HAPF is firstly studied, investigated and compared with the linear active power filter. Two limits are proposed in this study that divides the HAPF into non-linear, quasi-linear and linear operation regions. The design criteria of hysteresis band and sampling time can then be derived. Single-phase simulation and experimental results are given to verify the hysteresis control study of HAPF compared with active power filter. Finally, representative simulation and experimental results of a three-phase four-wire centre-split HAPF for power quality compensation are presented to demonstrate the validity of the hysteresis linearisation study.

8 February 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LWLei Wang
Lei Wang
Chi-Seng LamChi-Seng Lam
Chi-Seng Lam
MWMan-Chung Wong
Man-Chung Wong
This paper proposes a hybrid static synchronous compensator (hybrid-STATCOM) in a three-phase power transmission system that has a wide compensation range and low dc-link voltage. Because of these prominent characteristics, the system costs can be greatly reduced. In this paper, the circuit configuration of hybrid-STATCOM is introduced first. Its V-I characteristic is then analyzed, discussed, and compared with traditional STATCOM and capacitive-coupled STATCOM (C-STATCOM). The system parameter design is then proposed on the basis of consideration of the reactive power compensation range and avoidance of the potential resonance problem. After that, a control strategy for hybrid-STATCOM is proposed to allow operation under different voltage and current conditions, such as unbalanced current, voltage dip, and voltage fault. Finally, simulation and experimental results are provided to verify the wide compensation range and low dc-link voltage characteristics and the good dynamic performance of the proposed hybrid-STATCOM.

1 August 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Chi-Seng LamChi-Seng Lam
Chi-Seng Lam
MWMan-Chung Wong
Man-Chung Wong
WCWai-Hei Choi
Wai-Hei Choi
XCXiao-Xi Cui
Xiao-Xi Cui
HMHong-Ming Mei
Hong-Ming Mei
JLJian-Zheng Liu
Jian-Zheng Liu
This paper proposes an adaptive low-dc-link-voltage-controlled LC coupling hybrid active power filter ( LC-HAPF) with a neutral inductor, which can compensate both dynamic reactive power and current harmonics in three-phase four-wire distribution power systems. Due to its adaptive low-dc-link-voltage characteristic, it can obtain the least switching loss and switching noise and the best compensating performances, compared with the conventional fixed and newly adaptive dc-voltage-controlled LC-HAPFs. The design procedures of the dc-link voltage controller are discussed, so that the proportional and integral gains can be designed accordingly. Moreover, the general design procedures for the adaptive dc-voltage-controlled LC-HAPF with a neutral inductor are also given. The validity and effectiveness of the adaptive dc-link voltage-controlled LC -HAPF with a neutral inductor are confirmed by experimental results obtained from a 220-V 10-kVA laboratory prototype compared with the conventional fixed and adaptive dc-link voltage-controlled LC-HAPFs without a neutral inductor.