Auditory beat stimulation may be a promising new tool for the manipulation of cognitive processes and the modulation of mood-states. Here we aim to review the literature examining the most current applications of auditory beat stimulation and its targets. We give a brief overview of research on auditory steady-state responses and its relationship to auditory beat stimulation. We have summarized relevant studies investigating the neurophysiological changes related to auditory beat stimulation and how they impact upon the design of appropriate stimulation protocols. Focusing on binaural beat stimulation, we then discuss the role of monaural and binaural beat frequencies in cognition and mood-states, in addition to their efficacy in targeting disease symptoms. We aim to highlight important points concerning stimulation parameters and try to address why there are often contradictory findings with regard to the outcomes of auditory beat stimulation.
Background Radiological imaging guidelines are crucial for accurate diagnosis and optimal patient care as they result in standardized decisions and thus reduce inappropriate imaging studies. Purpose In the present study, we investigated the potential to support clinical decision-making using an interactive chatbot designed to provide personalized imaging recommendations from American College of Radiology (ACR) appropriateness criteria documents using semantic similarity processing. Methods We utilized 209 ACR appropriateness criteria documents as specialized knowledge base and employed LlamaIndex, a framework that allows to connect large language models with external data, and the ChatGPT 3.5-Turbo to create an appropriateness criteria contexted chatbot (accGPT). Fifty clinical case files were used to compare the accGPT's performance against general radiologists at varying experience levels and to generic ChatGPT 3.5 and 4.0. Results All chatbots reached at least human performance level. For the 50 case files, the accGPT performed best in providing correct recommendations that were "usually appropriate" according to the ACR criteria and also did provide the highest proportion of consistently correct answers in comparison with generic chatbots and radiologists. Further, the chatbots provided substantial time and cost savings, with an average decision time of 5 minutes and a cost of 0.19 € for all cases, compared to 50 minutes and 29.99 € for radiologists (both p < 0.01). Conclusion ChatGPT-based algorithms have the potential to substantially improve the decision-making for clinical imaging studies in accordance with ACR guidelines. Specifically, a context-based algorithm performed superior to its generic counterpart, demonstrating the value of tailoring AI solutions to specific healthcare applications.
Background: As an integral part of computer-assisted surgery, virtual surgical planning (VSP) leads to significantly better surgery results, such as for oral and maxillofacial reconstruction with microvascular grafts of the fibula or iliac crest. It is performed on a 2D computer desktop screen (DS) based on preoperative medical imaging. However, in this environment, VSP is associated with shortcomings, such as a time-consuming planning process and the requirement of a learning process. Therefore, a virtual reality (VR)–based VSP application has great potential to reduce or even overcome these shortcomings due to the benefits of visuospatial vision, bimanual interaction, and full immersion. However, the efficacy of such a VR environment has not yet been investigated. Objective: This study aimed to demonstrate the possible advantages of a VR environment through a substep of VSP, specifically the segmentation of the fibula (calf bone) and os coxae (hip bone), by conducting a training course in both DS and VR environments and comparing the results. Methods: During the training course, 6 novices were taught how to use a software application in a DS environment (3D Slicer) and in a VR environment (Elucis) for the segmentation of the fibula and os coxae, and they were asked to carry out the maneuvers as accurately and quickly as possible. Overall, 13 fibula and 13 os coxae were segmented for each participant in both methods (VR and DS), resulting in 156 different models (78 fibula and 78 os coxae) per method (VR and DS) and 312 models in total. The individual learning processes in both environments were compared using objective criteria (time and segmentation performance) and self-reported questionnaires. The models resulting from the segmentation were compared mathematically (Hausdorff distance and Dice coefficient) and evaluated by 2 experienced radiologists in a blinded manner. Results: A much faster learning curve was observed for the VR environment than the DS environment (β=.86 vs β=.25). This nearly doubled the segmentation speed (cm3/min) by the end of training, leading to a shorter time (P<.001) to reach a qualitative result. However, there was no qualitative difference between the models for VR and DS (P=.99). The VR environment was perceived by participants as more intuitive and less exhausting, and was favored over the DS environment. Conclusions: The more rapid learning process and the ability to work faster in the VR environment could save time and reduce the VSP workload, providing certain advantages over the DS environment.
Objectives: Diffusion-weighted imaging (DWI) enhances specificity in multiparametric breast MRI but is associated with longer acquisition time. Deep learning (DL) reconstruction may significantly shorten acquisition time and improve spatial resolution. In this prospective study, we evaluated acquisition time and image quality of a DL-accelerated DWI sequence with superresolution processing (DWIDL) in comparison to standard imaging including analysis of lesion conspicuity and contrast of invasive breast cancers (IBCs), benign lesions (BEs), and cysts. Materials and Methods: This institutional review board–approved prospective monocentric study enrolled participants who underwent 3 T breast MRI between August and December 2022. Standard DWI (DWISTD; single-shot echo-planar DWI combined with reduced field-of-view excitation; b-values: 50 and 800 s/mm2) was followed by DWIDL with similar acquisition parameters and reduced averages. Quantitative image quality was analyzed for region of interest–based signal-to-noise ratio (SNR) on breast tissue. Apparent diffusion coefficient (ADC), SNR, contrast-to-noise ratio, and contrast (C) values were calculated for biopsy-proven IBCs, BEs, and for cysts. Two radiologists independently assessed image quality, artifacts, and lesion conspicuity in a blinded independent manner. Univariate analysis was performed to test differences and interrater reliability. Results: Among 65 participants (54 ± 13 years, 64 women) enrolled in the study, the prevalence of breast cancer was 23%. Average acquisition time was 5:02 minutes for DWISTD and 2:44 minutes for DWIDL (P < 0.001). Signal-to-noise ratio measured in breast tissue was higher for DWISTD (P < 0.001). The mean ADC values for IBC were 0.77 × 10−3 ± 0.13 mm2/s in DWISTD and 0.75 × 10−3 ± 0.12 mm2/s in DWIDL without significant difference when sequences were compared (P = 0.32). Benign lesions presented with mean ADC values of 1.32 × 10−3 ± 0.48 mm2/s in DWISTD and 1.39 × 10−3 ± 0.54 mm2/s in DWIDL (P = 0.12), and cysts presented with 2.18 × 10−3 ± 0.49 mm2/s in DWISTD and 2.31 × 10−3 ± 0.43 mm2/s in DWIDL. All lesions presented with significantly higher contrast in the DWIDL (P < 0.001), whereas SNR and contrast-to-noise ratio did not differ significantly between DWISTD and DWIDL regardless of lesion type. Both sequences demonstrated a high subjective image quality (29/65 for DWISTD vs 20/65 for DWIDL; P < 0.001). The highest lesion conspicuity score was observed more often for DWIDL (P < 0.001) for all lesion types. Artifacts were scored higher for DWIDL (P < 0.001). In general, no additional artifacts were noted in DWIDL. Interrater reliability was substantial to excellent (k = 0.68 to 1.0). Conclusions: DWIDL in breast MRI significantly reduced scan time by nearly one half while improving lesion conspicuity and maintaining overall image quality in a prospective clinical cohort.
30 October 2023 in Expert Systems with Applications
Objectives: Levonorgestrel-releasing intrauterine contraceptive devices (LNG-IUDs) are designed to exhibit only local hormonal effects. There is an ongoing debate on whether LNG-IUDs can have side effects similar to systemic hormonal medication. Benign background parenchymal enhancement (BPE) in dynamic contrast–enhanced (DCE) MRI has been established as a sensitive marker of hormonal stimulation of the breast. We investigated the association between LNG-IUD use and BPE in breast MRI to further explore possible systemic effects of LNG-IUDs. Methods: Our hospital database was searched to identify premenopausal women without personal history of breast cancer, oophorectomy, and hormone replacement or antihormone therapy, who had undergone standardized DCE breast MRI at least twice, once with and without an LNG-IUD in place. To avoid confounding aging-related effects on BPE, half of included women had their first MRI without, the other half with, LNG-IUD in place. Degree of BPE was analyzed according to the ACR categories. Wilcoxon-matched-pairs signed-rank test was used to compare the distribution of ACR categories with vs. without LNG-IUD. Results: Forty-eight women (mean age, 46 years) were included. In 24/48 women (50% [95% CI: 35.9–64.1%]), ACR categories did not change with vs. without LNG-IUDs. In 23/48 women (48% [33.9–62.1%]), the ACR category was higher with vs. without LNG-IUDs; in 1/48 (2% [0–6%]), the ACR category was lower with vs. without LNG-IUDs. The change of ACR category depending on the presence or absence of an LNG-IUD proved highly significant (p < 0.001). Conclusion: The use of an LNG-IUD can be associated with increased BPE in breast MRI, providing further evidence that LNG-IUDs do have systemic effects. Key Points: • The use of levonorgestrel-releasing intrauterine contraceptive devices is associated with increased background parenchymal enhancement in breast MRI. • This suggests that hormonal effects of these devices are not only confined to the uterine cavity, but may be systemic. • Potential systemic effects of levonorgestrel-releasing intrauterine contraceptive devices should therefore be considered.