Cristine D'Agostino

Dr. Cristine D'Agostino

Sapienza Univeristy of Rome

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2021 in Electrochem
Verified
Journal Article
Open access
PDF file
Rosaceleste ZumpanoRosaceleste Zumpano
Rosaceleste Zumpano
FPFrancesca Polli
Francesca Polli
CDCristine D'Agostino
Cristine D'Agostino
RARiccarda Antiochia
Riccarda Antiochia
Gabriele FaveroGabriele Favero
Gabriele Favero
Franco MazzeiFranco Mazzei
Franco Mazzei
Electrochemical immunosensors are affinity-based biosensors characterized by several useful features such as specificity, miniaturizability, low cost and simplicity, making them very interesting for many applications in several scientific fields. One of the significant issues in the design of electrochemical immunosensors is to increase the system’s sensitivity. Different strategies have been developed, one of the most common is the use of nanostructured materials as electrode materials, nanocarriers, electroactive or electrocatalytic nanotracers because of their abilities in signal amplification and biocompatibility. In this review, we will consider some of the most used nanostructures employed in the development of electrochemical immunosensors (e.g., metallic nanoparticles, graphene, carbon nanotubes) and many other still uncommon nanomaterials. Furthermore, their diagnostic applications in the last decade will be discussed, referring to two relevant issues of present-day: the detection of tumor markers and viruses.

2 August 2022 in Talanta
Verified
Journal Article
Open access
FPFrancesca Polli
Francesca Polli
CDCristine D'Agostino
Cristine D'Agostino
Rosaceleste ZumpanoRosaceleste Zumpano
Rosaceleste Zumpano
VMViviana De Martino
Viviana De Martino
Gabriele FaveroGabriele Favero
Gabriele Favero
Franco MazzeiFranco Mazzei
Franco Mazzei
We report a new sensitive label-free electrochemical immunosensor to detect Vitamin D3 (25-OHD3) in untreated serum samples. To this aim, a graphite screen printed electrode (SPE) was modified using cysteamine (CYM) functionalized core-shell magnetic nanoparticles (Au@MNPs) then, the 25-OHD3 antibody (AbD) was immobilized via glutaraldehyde crosslinking. The several steps involved in the immunosensor development and 25-OHD3 analysis were monitored by using differential pulse voltammetry (DPV). The developed immunosensor showed a LOD of 2.4 ng mL-1 and a linear range between 7.4 and 70 ng mL-1. The effectiveness of the immunosensor in human serum analysis was assessed by comparing the results obtained with the chemiluminescence-immunoassay (CLIA) reference method. The high sensitivity and excellent agreement with the reference method suggest its potential use as a POCT to monitor hypovitaminosis 25-OHD levels.

18 January 2022 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
Rosaceleste ZumpanoRosaceleste Zumpano
Rosaceleste Zumpano
MMManuela Manghisi
Manuela Manghisi
FPFrancesca Polli
Francesca Polli
CDCristine D'Agostino
Cristine D'Agostino
FIFederica Ietto
Federica Ietto
Franco MazzeiFranco Mazzei
Franco Mazzei

15 July 2023 in Molecules
Verified
Journal Article
Open access
PDF file
CDCristine D'Agostino
Cristine D'Agostino
CCClaudia Chillocci
Claudia Chillocci
FPFrancesca Polli
Francesca Polli
Luca SuraceLuca Surace
Luca Surace
FSFederica Simonetti
Federica Simonetti
Rosaceleste ZumpanoRosaceleste Zumpano
Rosaceleste Zumpano
This work aimed to develop an easy-to-use smartphone-based electrochemical biosensor to quickly assess a coffee blend’s total polyphenols (Phs) content at the industrial and individual levels. The device is based on a commercial carbon-based screen-printed electrode (SPE) modified with multi-walled carbon nanotubes (CNTs) and gold nanoparticles (GNPs). At the same time, the biological recognition element, Laccase from Trametes versicolor, TvLac, was immobilized on the sensor surface by using glutaraldehyde (GA) as a cross-linking agent. The platform was electrochemically characterized to ascertain the influence of the SPE surface modification on its performance. The working electrode (WE) surface morphology characterization was obtained by scanning electron microscopy (SEM) and Fourier-transform infrared (FT-IR) imaging. All the measurements were carried out with a micro-potentiostat, the Sensit Smart by PalmSens, connected to a smartphone. The developed biosensor provided a sensitivity of 0.12 μA/μM, a linear response ranging from 5 to 70 μM, and a lower detection limit (LOD) of 2.99 μM. Afterward, the biosensor was tested for quantifying the total Phs content in coffee blends, evaluating the influence of both the variety and the roasting degree. The smartphone-based electrochemical biosensor’s performance was validated through the Folin–Ciocâlteu standard method.

14 September 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
CDCristine D'Agostino
Cristine D'Agostino
Rocco CancelliereRocco Cancelliere
Rocco Cancelliere
ACAntonio Ceccarelli
Antonio Ceccarelli
Danila MosconeDanila Moscone
Danila Moscone
LCLoredana Cozzi
Loredana Cozzi
Laura MicheliLaura Micheli
Laura Micheli
Globally, waterborne viral infections significantly threaten public health. While current European Union regulations stipulate that drinking water must be devoid of harmful pathogens, they do not specifically address the presence of enteric viruses in water used for irrigation or food production. Traditional virus detection methods rely on molecular biology assays, requiring specialized personnel and laboratory facilities. Here, we describe an electrochemical sandwich enzyme-linked immunomagnetic assay (ELIME) for the detection of the hepatitis A virus (HAV) in water matrices. This method employed screen-printed electrodes as the sensing platform and utilized commercially available pre-activated magnetic beads to provide a robust foundation for the immunological reaction. The ELIME assay demonstrated exceptional analytical performance in only 185 min achieving a detection limit of 0.5 genomic copies per milliliter (g.c./mL) and exhibiting good reproducibility with a relative standard deviation (RSD) of 7% in HAV-spiked drinking and processing water samples. Compared with the real-time RT-qPCR method described in ISO 15216-1, the ELIME assay demonstrated higher sensitivity, although the overall linearity of the method was moderate. These analytical attributes highlight the potential of the ELIME assay as a rapid and viable alternative for HAV detection in water used for agriculture and food processing.

26 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
CDCristine D'Agostino
Cristine D'Agostino
CCClaudia Chillocci
Claudia Chillocci
FPFrancesca Polli
Francesca Polli
Luca SuraceLuca Surace
Luca Surace
FSFederica Simonetti
Federica Simonetti
Rosaceleste ZumpanoRosaceleste Zumpano
Rosaceleste Zumpano
This work aimed to develop an easy-to-use smartphone-based electrochemical biosensor to quickly assess coffee blend's total polyphenol (Phs) content at industrial and individual level. The device is based on a commercial carbon-based screen-printed electrode (SPE) modified with multi-walled carbon nanotubes (CNTs) and gold nanoparticles (GNPs). At the same time, the biotransducer, Laccase from Trametes versicolor, TvLac, was immobilized on the sensor surface by using glutaraldehyde (GA) as cross-linking agent. The platform was electrochemically characterized to ascertain the influence of the SPE surface modification on its performance. The working electrode (WE) surface morphology characterization was obtained by scanning electron microscopy (SEM) and Fourier-transform infrared (FT-IR) imaging. All the measurements were carried out with a micro-potentiostat Sensit Smart by PalmSens connected to a smartphone. The developed biosensor provided a sensitivity of 0.12 μA/μM, a linear response ranging from 5 to 70 μM, and a lower detection limit (LOD) of 2.99 μM. Afterwards, the biosensor was tested for quantifying the total Phs content in coffee blends, evaluating the influence of both the variety and the roasting degree. The smartphone-based electrochemical biosensor performance has been validated though the Folin-Ciocâlteu standard method.