Riccarda Antiochia

Prof. Riccarda Antiochia

Sapienza University of Rome
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2004 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
ILIrma Lavagnini
Irma Lavagnini
RARiccarda Antiochia
Riccarda Antiochia
FMFranco Magno
Franco Magno

1 March 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Paolo BollellaPaolo Bollella
Paolo Bollella
GFGiovanni Fusco
Giovanni Fusco
CTCristina Tortolini
Cristina Tortolini
GSGabriella Sanzò
Gabriella Sanzò
Gabriele FaveroGabriele Favero
Gabriele Favero
RARiccarda Antiochia
Riccarda Antiochia

1 January 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Paolo BollellaPaolo Bollella
Paolo Bollella
SSSanjiv Sharma
Sanjiv Sharma
ACAnthony Edward George Cass
Anthony Edward George Cass
RARiccarda Antiochia
Riccarda Antiochia

10 January 2019 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
Paolo BollellaPaolo Bollella
Paolo Bollella
SSSanjiv Sharma
Sanjiv Sharma
ACAnthony Edward George Cass
Anthony Edward George Cass
RARiccarda Antiochia
Riccarda Antiochia

30 June 2019 in Catalysts
Verified
Journal Article
Open access
PDF file
Paolo BollellaPaolo Bollella
Paolo Bollella
SSSanjiv Sharma
Sanjiv Sharma
ACAnthony E. G. Cass
Anthony E. G. Cass
Federico TascaFederico Tasca
Federico Tasca
RARiccarda Antiochia
Riccarda Antiochia
In this paper, we present the first highly porous gold (h-PG) microneedles-based second-generation biosensor for minimally invasive monitoring of glucose in artificial interstitial fluid (ISF). A highly porous microneedles-based electrode was prepared by a simple electrochemical self-templating method that involves two steps, gold electrodeposition and hydrogen bubbling at the electrode, which were realized by applying a potential of −2 V versus a saturated calomel electrode (SCE). The highly porous gold surface of the microneedles was modified by immobilization of 6-(ferrocenyl)hexanethiol (FcSH) as a redox mediator and subsequently by immobilization of a flavin adenine dinucleotide glucose dehydrogenase (FAD-GDH) enzyme using a drop-casting method. The microneedles-based FcSH/FAD-GDH biosensor allows for the detection of glucose in artificial interstitial fluid with an extended linear range (0.1–10 mM), high sensitivity (50.86 µA cm−2 mM−1), stability (20% signal loss after 30 days), selectivity (only ascorbic acid showed a response about 10% of glucose signal), and a short response time (3 s). These properties were favourably compared to other microneedles-based glucose biosensors reported in the literature. Finally, the microneedle-arrays-based second-generation biosensor for glucose detection was tested in artificial interstitial fluid opportunely spiked with different concentrations of glucose (simulating healthy physiological conditions while fasting and after lunch) and by placing the electrode into a simulated chitosan/agarose hydrogel skin model embedded in the artificial ISF (continuous glucose monitoring). The obtained current signals had a lag-time of about 2 min compared to the experiments in solution, but they fit perfectly into the linearity range of the biosensor (0.1–10 mM). These promising results show that the proposed h-PG microneedles-based sensor could be used as a wearable, disposable, user-friendly, and automated diagnostic tool for diabetes patients.

24 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Paolo BollellaPaolo Bollella
Paolo Bollella
Lo GortonLo Gorton
Lo Gorton
RARiccarda Antiochia
Riccarda Antiochia
Dehydrogenase based bioelectrocatalysis has been increasingly exploited in recent years in order to develop new bioelectrochemical devices, such as biosensors and biofuel cells, with improved performances. In some cases, dehydrogeases are able to directly exchange electrons with an appropriately designed electrode surface, without the need for an added redox mediator, allowing bioelectrocatalysis based on a direct electron transfer process. In this review we briefly describe the electron transfer mechanism of dehydrogenase enzymes and some of the characteristics required for bioelectrocatalysis reactions via a direct electron transfer mechanism. Special attention is given to cellobiose dehydrogenase and fructose dehydrogenase, which showed efficient direct electron transfer reactions. An overview of the most recent biosensors and biofuel cells based on the two dehydrogenases will be presented. The various strategies to prepare modified electrodes in order to improve the electron transfer properties of the device will be carefully investigated and all analytical parameters will be presented, discussed and compared.