Due to the complexity of the human musculoskeletal system and intra/intersubjects variability, powered exoskeletons are prone to human-robot misalignments. These induce undesired interaction forces that may jeopardize safe operation. Uncompensated inertia of the robotic links also generates spurious interaction forces. Current design approaches to compensate for misalignments rely on the use of auxiliary passive degrees of freedom that unavoidably increase robot inertia, which potentially affects their effectiveness in reducing undesired interaction forces. Assessing the relative impact of misalignment and robot inertia on the wearer can, therefore, provide useful insights on how to improve the effectiveness of such approaches, especially in those situations where the dynamics of the movement are quasi-periodic and, therefore, predictable such as in gait. In this paper, we studied the effects of knee joint misalignments on the wearer's gait, by using a treadmill-based exoskeleton developed by our group, the ALEX II. Knee joint misalignments were purposely introduced by adjusting the mismatch between the length of the robot thigh and that of the human thigh. The amount of robot inertia reflected to the user was adjusted through control. Results evidenced that knee misalignment significantly changes human-robot interaction forces, especially at the thigh interface, and this effect can be attenuated by actively compensating for robot inertia. Misalignments caused by an excessively long robot thigh are less critical than misalignments of equal magnitude deriving from an excessively short robot thigh.
13 October 2014 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
A novel robot-aided assist-as-needed gait training paradigm has been developed recently. This paradigm encourages subjects' active participation during training. Previous pilot studies demonstrated that assist-as-needed robot-aided gait training (RAGT) improves treadmill walking performance post-stroke. However, it is not known if there is an over-ground transfer of the training effects from RAGT on treadmill or long-term retention of the effects. The purpose of the current study was to examine the effects of assist-as-needed RAGT on over-ground walking pattern post-stroke. Nine stroke subjects received RAGT with visual feedback of each subject's instantaneous ankle malleolus position relative to a target template for 15 40-minute sessions. Clinical evaluations and gait analyses were performed before, immediately after, and 6 months post-training. Stroke subjects demonstrated significant improvements and some long-term retention of the improvements in their self-selected over-ground walking speed, Dynamic Gait Index, Timed Up and Go, peak knee flexion angle during swing phase and total hip joint excursion over the whole gait cycle for their affected leg . These preliminary results demonstrate that subjects improved their over-ground walking pattern and some clinical gait measures post-training suggesting that assist-as-needed RAGT including visual feedback may be an effective approach to improve over-ground walking pattern post-stroke.
21 November 2013 in Expert Review of Medical Devices
In this paper, we discuss robot-mediated neurorehabilitation as a significant emerging field in clinical medicine. Stroke rehabilitation is advancing toward more integrated processes, using robotics to facilitate this integration. Rehabilitation approaches have tremendous value in reducing long-term impairments in stroke patients during hospitalization and after discharge, of which robotic systems are a new modality that can provide more effective rehabilitation. The function of robotics in rehabilitative interventions has been examined extensively, generating positive yet not completely satisfactory clinical results. This article presents state-of-the-art robotic systems and their prospective function in poststroke rehabilitation of the upper and lower limbs.
10 December 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Wearable sensors have been proposed as alternatives to traditional laboratory equipment for low-cost and portable real-time gait analysis in unconstrained environments. However, the moderate accuracy of these systems currently limits their widespread use. In this paper, we show that support vector regression (SVR) models can be used to extract accurate estimates of fundamental gait parameters (i.e., stride length, velocity, and foot clearance), from custom-engineered instrumented insoles (SportSole) during walking and running tasks. Additionally, these learning-based models are robust to inter-subject variability, thereby making it unnecessary to collect subject-specific training data. Gait analysis was performed in N=14 healthy subjects during two separate sessions, each including 6-minute bouts of treadmill walking and running at different speeds (i.e., 85% and 115% of each subject's preferred speed). Gait metrics were simultaneously measured with the instrumented insoles and with reference laboratory equipment. SVR models yielded excellent intraclass correlation coefficients (ICC) in all the gait parameters analyzed. Percentage mean absolute errors (MAE%) in stride length, velocity, and foot clearance obtained with SVR models were 1.37%±0.49%, 1.23%±0.27%, and 2.08%±0.72% for walking, 2.59%±0.64%, 2.91%±0.85%, and 5.13%±1.52% for running, respectively. These findings provide evidence that machine learning regression is a promising new approach to improve the accuracy of wearable sensors for gait analysis.
Sophia-3 (string-operated planar haptic interface for arm rehabilitation) is a planar cable-driven device with a tilting working plane. It represents the first application of the adaptive cable-driven design paradigm recently introduced by the authors, featuring a moving pulley-block that allows the robot to achieve excellent force capabilities, despite the low number of cables. This study presents the design, kinematics, and control of the device and results of experimental validation on healthy subjects.
29 June 2017 in IEEE Robotics and Automation Letters
Quantitative analysis of the plantar pressure distribution during dynamic tasks can facilitate diagnosis of foot and ankle dysfunctions and prevent potential injuries by providing detailed information about weight bearing and weight shifting patterns. Traditional laboratory measurements are currently limited by high operating costs and lack of portability. The use of instrumented insoles capable of capturing kinematic and kinetic gait parameters as subjects perform out-of-the-lab dynamic activities is a promising approach to overcome these limitations. This letter introduces SportSole, a fully portable system that can measure spatiotemporal gait parameters and center of pressure (CoP) trajectories. Wearing the SportSole, nine able-bodied subjects completed a walking session followed by a running session, each consisting of 10 full laps along a 16-meter straight-line path. Accuracy and precision of CoP trajectories and kinematic parameters were assessed using an electronic walkway as the reference system. After calibration, mean deviations in the CoP were 0.61 ± 0.05 cm (RMSE ± SD) for walking and 0.72 ± 0.08 cm for running. Deviations in stride length, stride time, and velocity were 1.66 ± 0.18 cm, 0.006 ± 0.003 s, and 1.65 ± 0.10 cm/s for walking, 1.91 ± 0.19 cm, 0.01 ± 0.03 s, and 2.67 ± 0.38 cm/s for running. These promising results indicate that the proposed system has the potential to be used for out-of-the-lab gait analysis of walking and running.