Daniele Passaretti

Mr. Daniele Passaretti

Otto-von-Guericke University Magdeburg, Magdeburg, Saxony-Anhalt, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019
Verified
Conference Paper
Closed access
Daniele PassarettiDaniele Passaretti
Daniele Passaretti
JJJan Moritz Joseph
Jan Moritz Joseph
TPThilo Pionteck
Thilo Pionteck
This paper provides a survey on hardware architectures and programming models for FPGAs in medical radiology applications. This area imposes many challenging constraints on the underlying hardware platform that can be solved best by FPGAs: hard real-time, low latency inter-device communication, safety, huge data volume, and on-the-fly image processing tasks. We consider these aspects from the application as well as from the FPGA design perspective and provide a definition and classification of the most relevant challenges, trends, and requirements. Therefore, we analyse different application scenarios ranging from basic Computed Tomography (CT) to modern Interventional Radiology systems. The main focus of our work lies on CT appliances. Finally, we discuss trends of architectures solutions and programming models in these complex systems. By means of this systematic literature survey, we derive an architectural model from real-time, patient and application constraints for hardware design and system engineering tasks.

1 September 2020
Verified
Conference Paper
Closed access
Daniele PassarettiDaniele Passaretti
Daniele Passaretti
TPThilo Pionteck
Thilo Pionteck
In the last decades, the continuous advances of computed tomography sensor technology and the different medical use cases have opened new challenges for data acquisition systems: i.e. controlling and synchronising different subsystems, and acquiring and managing the huge amount of data, under real-time requirements. System-on-Chip-FPGAs are perfectly suited for all these tasks that involve hardware and software. In this paper, we propose a new acquisition system architecture for Clinical Computed Tomography (CT) for SoC, based on Hardware/Software Co-Design methodology. We discuss how to partition the different tasks (controlling, acquisition, synchronisation) on Programmable Logic (PL) and Processing System (PS) parts. Moreover, we analyse the interactions between these parts for having the performance required from the CT application. This architecture is able to control and synchronise all components inside the CT, acquire data via the optical channel, and process real-time image data in the order of 10 Gb/s, inside a single SoC.

1 May 2021
Verified
Conference Paper
Closed access
Daniele PassarettiDaniele Passaretti
Daniele Passaretti
TPThilo Pionteck
Thilo Pionteck
In this paper, we present a novel Configurable Pipelined Datapath for custom Data Acquisition Systems (DASs) in the context of Interventional Computed Tomography (iCT). The introduction of new medical techniques during surgery results in a multitude of challenging requirements on the hardware architecture (e.g., real-time data processing, high data-rate, hard deadline on data acquisition and storage). Therefore, we propose a Pipelined Datapath for System-on-Chip FPGAs, that can be configured at design time and run time. It supports all data processing steps from the detector sensors’ data acquisition to the image-processing reconstruction system. It can be configured, depending on the CT physical limitations and the medical scenarios. Besides, the Pipelined Datapath avoids any buffering on off-chip memory, differently from other architectures in literature.

2 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Daniele PassarettiDaniele Passaretti
Daniele Passaretti
Mukesh GhoshMukesh Ghosh
Mukesh Ghosh
SAShiras Abdurahman
Shiras Abdurahman
MEMicaela Lambru Egito
Micaela Lambru Egito
TPThilo Pionteck
Thilo Pionteck
In computed tomography imaging, the computationally intensive tasks are the pre-processing of 2D detector data to generate total attenuation or line integral projections and the reconstruction of the 3D volume from the projections. This paper proposes the optimization of the X-ray pre-processing to compute total attenuation projections by avoiding the intermediate step to convert detector data to intensity images. In addition, to fulfill the real-time requirements, we design a configurable hardware architecture for data acquisition systems on FPGAs, with the goal to have a “on-the-fly” pre-processing of 2D projections. Finally, this architecture was configured for exploring and analyzing different arithmetic representations, such as floating-point and fixed-point data formats. This design space exploration has allowed us to find the best representation and data format that minimize execution time and hardware costs, while not affecting image quality. Furthermore, the proposed architecture was integrated in an open-interface computed tomography device, used for evaluating the image quality of the pre-processed 2D projections and the reconstructed 3D volume. By comparing the proposed solution with the state-of-the-art pre-processing algorithm that make use of intensity images, the latency was decreased 4.125×, and the resources utilization of ∼6.5×, with a mean square error in the order of 10−15 for all the selected phantom experiments. Finally, by using the fixed-point representation in the different data precisions, the latency and the resource utilization were further decreased, and a mean square error in the order of 10−1 was reached.

16 January 2025 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
NDNicola D'Ascenzo
Nicola D'Ascenzo
JCJingbin Chen
Jingbin Chen
HLHui Lao
Hui Lao
Daniele PassarettiDaniele Passaretti
Daniele Passaretti
EAEmanuele Antonecchia
Emanuele Antonecchia
QXQingguo Xie
Qingguo Xie
Silicon photomultipliers (SiPMs) fabricated using standard CMOS processes offer the advantages of compatibility with on-chip digital circuits, making them promising candidates among low-photon flux sensors. However, the high noise and low-photon detection efficiency (PDE) of CMOS SiPMs have limited their widespread adoption. Here, we present a novel SiPM obtained within a standard 0.11- $\mu $ m CMOS process. We report how guard ring (GR) width and distance from shallow trench isolation (STI) may affect the noise performance, and we optimize for them. The final device demonstrates performance that is competitive with both custom-based commercial technologies and other CMOS-based SiPMs, featuring an unprecedented peak PDE of 62% at 420 nm, a dark count rate (DCR) of $\mathbf {\text {(}{174}\pm {7}\text {)}}$ kcps/mm $\mathbf {^{{2}}}$ , a gain of $\mathbf {\text {(}{2}.{0}\pm {0}.{2}\text {)}\times {10}^{{6}}}$ and a single-photon time resolution (SPTR) of $\mathbf {\text {(}{74}\pm {3} \text {)}}$ ps [full width at half maximum (FWHM)] at an excess bias voltage of 3 V.

14 December 2022
Verified
Book Chapter
Closed access
PDF file
Daniele PassarettiDaniele Passaretti
Daniele Passaretti
FBFelix Boehm
Felix Boehm
MWMartin Wilhelm
Martin Wilhelm
TPThilo Pionteck
Thilo Pionteck