Danilo Andrés Molina-Vidal

Mr. Danilo Andrés Molina-Vidal

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2025 in Sensors
Verified
Journal Article
Open access
PLPablo Fernando Cevallos Larrea
Pablo Fernando Cevallos Larrea
LGLeimer Guambaña-Calle
Leimer Guambaña-Calle
Danilo Andrés Molina-VidalDanilo Andrés Molina-Vidal
Danilo Andrés Molina-Vidal
MGMathews Castillo Guerrero
Mathews Castillo Guerrero
ANAluizio D’aFfonsêca Netto
Aluizio D’aFfonsêca Netto
CTCarlos Julio Tierra-Criollo
Carlos Julio Tierra-Criollo
The simultaneous analysis of electrophysiological signals from various physiological systems, such as the brain, skeletal muscles, and cardiac muscles, has become increasingly necessary in both clinical and research settings. However, acquiring multiple modalities of electrophysiological data often necessitates the use of diverse, specialized technological tools, which can complicate the establishment of a comprehensive multimodal experimental setup. This paper introduces a prototype system, named the Multimodal–Multichannel Acquisition Module—MADQ, designed for the simultaneous acquisition of multimodal and multichannel electrophysiological and general-purpose signals. The MADQ comprises three distinct capturing blocks, each equipped with separate reference circuits, supporting a total of up to 40 electrophysiological input channels, alongside 4 channels of analog input and 4 channels of digital input signal. The system is capable of sampling frequencies up to 16 kHz. Key features of the MADQ include individually configurable bipolar recording, lead-off detection capability, and real-time online filtering. The system’s functional performance was characterized through metrics such as Input-Referred Noise (IRN), Noise-Free Bits (NFB), and Effective Number of Bits (ENOB) across varying gain and sampling frequencies. Preliminary experiments, conducted in a setup emulating a sleep study with auditory evoked potential detection, demonstrate the system’s potential for integration into multimodal experimental scenarios.

21 May 2023
Verified
Book Chapter
Closed access
PDF file
Danilo Andrés Molina-VidalDanilo Andrés Molina-Vidal
Danilo Andrés Molina-Vidal
PLP. Cevallos Larrea
P. Cevallos Larrea
LCL. Guambaña Calle
L. Guambaña Calle
DLD. Liquori
D. Liquori
CTCarlos Julio Tierra-Criollo
Carlos Julio Tierra-Criollo

29 April 2025
Verified
Book Chapter
Open access
PDF file
TCTatiana Dolores Cárdenas-Guaraca
Tatiana Dolores Cárdenas-Guaraca
Danilo Andrés Molina-VidalDanilo Andrés Molina-Vidal
Danilo Andrés Molina-Vidal
Vladimir Robles-BykbaevVladimir Robles-Bykbaev
Vladimir Robles-Bykbaev
Knee osteoarthritis represents a medical care challenge, requiring tools that improve the accuracy of monitoring during rehabilitation. The tools found present limitations for a complete analysis. In this perspective, we developed a platform to analyze electromyography (EMG) signals stored on file or captured online by an acquisition module. To evaluate the platform, an EMG acquisition of four leg muscles of a healthy subject was performed. Also, EMG signals from the database were used to visualize and calculate typical values used for EMG rehabilitation analysis. The interface allowed online capture and processing of 4 EMG channels. Using the database signals, we applied the envelope, histogram, Fourier transform, rectified, gain, and mean frequency. The values found are in the range found in the literature. The results suggest the user interface can be used for monitoring knee osteoarthritis rehabilitation or other muscle diseases requiring EMG-biofeedback.

1 January 2025 in INGENIUS
Verified
Journal Article
Open access
PDF file
PSP. Silverio-Cevallos
P. Silverio-Cevallos
Danilo Andrés Molina-VidalDanilo Andrés Molina-Vidal
Danilo Andrés Molina-Vidal
CTCarlos Julio Tierra-Criollo
Carlos Julio Tierra-Criollo
PLPablo Fernando Cevallos Larrea
Pablo Fernando Cevallos Larrea
Multichannel Functional Electrical Stimulation (FES) technology is widely employed in artificial motor control research. This study presents the design and evaluation of a four-channel, remotely controlled surface electrical muscle stimulator prototype. The prototype introduces a modern alternative for the control block, employing a Wi-Fi-enabled solution based on the ESP32 microcontroller. This controller enables remote configuration of activation sequences for individual channels and supports extensive customization of parameters for a biphasic waveform stimulus. The current signal is demultiplexed into four outputs. Additionally, this study provides a detailed functional evaluation of the amplification stage and examines the load-dependent limitations of the output current magnitude. Preliminary experimental testing demonstrates the prototype's ability to generate controlled stimulation sequences in hand muscles. The prototype's functional and experimental performance suggests its potential application in artificial motor control research.

9 August 2025
Verified
Book Chapter
Closed access
PDF file
Danilo Andrés Molina-VidalDanilo Andrés Molina-Vidal
Danilo Andrés Molina-Vidal
VMV. Mattos
V. Mattos
PCP. F. Cevallos-Larrea
P. F. Cevallos-Larrea
CTC. J. Tierra-Criollo
C. J. Tierra-Criollo

13 December 2023
Verified
Book Chapter
Open access
PDF file
Danilo Andrés Molina-VidalDanilo Andrés Molina-Vidal
Danilo Andrés Molina-Vidal
PLP. Cevallos Larrea
P. Cevallos Larrea
LCL. Guambaña Calle
L. Guambaña Calle
DLD. Liquori
D. Liquori
CTCarlos Julio Tierra-Criollo
Carlos Julio Tierra-Criollo
'Correction to: Design and Evaluation of a Prototype of Dual Channel Electrical Stimulator: Application in the Assessment of Current Perception Thresholds to Multiple Stimuli' published in 'Smart Technologies, Systems and Applications'