David Božiček

Dr. David Božiček

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
David BožičekDavid Božiček
David Božiček
JPJitka Peterková
Jitka Peterková
JZJiri Zach
Jiri Zach
Mitja KoširMitja Košir
Mitja Košir

1 February 2023 in Buildings
Verified
Journal Article
Open access
PDF file
JZJiri Zach
Jiri Zach
VNVitezslav Novak
Vitezslav Novak
JPJitka Peterková
Jitka Peterková
JBJan Bubenik
Jan Bubenik
Mitja KoširMitja Košir
Mitja Košir
ZKZdeněk Krejza
Zdeněk Krejza
This study is devoted to the possibility of using advanced insulation materials, such as Vacuum Insulation Panels (VIP), in the insulation and reconstruction of buildings, in connection with the green elements that are installed on the facade in the case of the use of external thermal insulation composite systems (ETICS). The use of VIP as part of the insulation system will result in a significant reduction in the required thickness of the insulation layer. In turn, the reduced overall thickness of the system will allow for easier direct anchoring of the elements of the green facade through the insulating layer to the base of the structure. The research carried out proves that, by using VIP in the insulation system (with a VIP thickness of 30 mm in combination with 20 mm of extruded polystyrene XPS), the thermal insulation properties can be significantly improved and, thus, the thickness of the insulation system can be reduced to 1/3 of the thickness of conventional insulation (while achieving the same thermal resistance), thereby enabling the anchoring of green elements on the surface of such an insulation system.

1 October 2017 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
MDM Dovjak
M Dovjak
Mitja KoširMitja Košir
Mitja Košir
Luka PajekLuka Pajek
Luka Pajek
NIN Iglič
N Iglič
David BožičekDavid Božiček
David Božiček
RKR Kunič
R Kunič
As the environmental awareness of the public is rising and at the same time contemporary buildings are becoming more and more energy efficient, the focus is shifting towards the usage of environmentally friendly building products. Human decisions are often driven by emotions and perceptions. Consequently, there exists a strong tendency towards preferring "natural" constructional products to the synthetic ones, especially in the case of thermal insulations. Life cycle assessment (LCA) has enabled an opportunity to widen the meaning of the word "environmentally friendly", giving researchers and building designers an objective decision making tool to determine the environmental impact of building products, building components and buildings as a whole. The purpose of this study was to compare the environmental impact of various thermal insulations for the cradle to gate life cycle stages, based on a unified functional unit. Overall, 15 most commonly used thermal insulation products were analysed and classified into natural and synthetic groups. Based on the differentiation, we compared the impact in the selected environmental categories and identified the most influential environmental drivers. The results show that in some environmental categoriesnatural thermal insulations perform better (i.e. global warming potential), whilein others (i.e. eutrophication potential) they underperform. However, environmental impact trends can be identified, specifically for the natural and the synthetic materials.

20 July 2023 in Building Research & Information
Verified
Journal Article
Open access
David BožičekDavid Božiček
David Božiček
YAYoussef Almezeraani
Youssef Almezeraani
Mitja KoširMitja Košir
Mitja Košir

18 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
David BožičekDavid Božiček
David Božiček
RKRoman Kunič
Roman Kunič
AKAleš Krainer
Aleš Krainer
Uroš StritihUroš Stritih
Uroš Stritih
MDMateja Dovjak
Mateja Dovjak
Upgrades in building energy efficiency codes led to differences between buildings designed according to outdated codes and those with most recent requirements. In this context, our study investigates the influence of external wall thermal transmittance, thermal inertia, and orientation on energy demand (heating, cooling) and occupant thermal comfort. Simulation models of an office building were designed, varying (i) the thermal transmittance values (0.20 and 0.60 W/(m2K)), (ii) the room orientation (four cardinal directions), and (iii) the wall thermal inertia (approximately 60 kJ/(m2K) for low and 340 kJ/(m2K) for high thermal inertia. The energy demand for heating and cooling seasons was calculated for Ljubljana using EnergyPlus 9.0.0 software. The reduction of the external wall thermal transmittance value from 0.6 W/(m2K) to 0.2 W/(m2K) contributes to significant energy savings (63% for heating and 37% for cooling). Thermal inertia showed considerable potential for energy savings, especially in the cooling season (20% and 13%, depending on the external wall insulation level). In addition, the orientation proved to have a notable impact on heating and cooling demand, however not as pronounced as thermal inertia (up to 7% total energy demand). Comparison of the thermal comfort results showed that when internal air temperatures are identically controlled in all the rooms (i.e., internal air temperature is not an influencing factor), the external wall thermal transmittance, thermal inertia, and room orientation show negligible influence on the average occupant thermal comfort. The simultaneous achievement of thermally comfortable conditions in the working environment and low energy use can only be achieved by simultaneously considering the U-value and thermal inertia.

1 May 2025 in Recycling
Verified
Journal Article
Open access
PDF file
JZJiri Zach
Jiri Zach
JPJitka Peterková
Jitka Peterková
VNVítězslav Novák
Vítězslav Novák
Mitja KoširMitja Košir
Mitja Košir
David BožičekDavid Božiček
David Božiček
The ever-increasing requirements in the field of energy efficiency of buildings imply the necessity of using an ever-increasing amount of insulation in building structures. However, together with the requirements of the new EPBD directive EU/2024/1275, it is also necessary to monitor the carbon footprint of individual materials incorporated into the building structure. The aim of the research work is to substitute primary raw materials used for the production of vacuum insulation panels (VIPs) with secondary cellulose fibers produced by recycling newsprint. Five recipes were proposed to verify the substitution effect for individual key raw materials of core insulation for VIPs. Key (primarily thermal insulation) properties were determined on laboratory-produced samples, and it was found that the proposed hybrid core insulations with secondary cellulose fibers from recycled newsprint exhibit very favorable properties and could be used for the production of VIPs used in building structures.