Gain amplitude modulation multichannel ASIC (GAMMA) is a 16-channel application specified integrated circuit (ASIC), designed in 0.35- $\mu \text{m}$ technology to read the charge provided by silicon photomultipliers (SiPMs) on a wide amplitude range. This chip was designed to satisfy the demanding requirements of the INFN the GAMMA project, where a 3” $\times3$ ” large lanthanum bromide crystal is to be read by SiPMs, aiming at state-of-the-art energy resolution. Because the energy range of the application is 100 keV–20 MeV, signals in a wide dynamic range (DR) have to be processed by the ASIC. This wide DR requirement raised the necessity of an adaptive gain change solution in order to guarantee a high signal-to-noise ratio together with a large full-scale range. While the ASIC input stage features a programmable static gain, the analog filtering channel exploits a self-triggered gated integrator stage with an automatically adjusted gain for each detected input current pulse; one of the following values is selected: 10, 2, or 0.83 [mV/pC]. The gated integrator gain is predictively adjusted before the circuit reaches saturation due to a time-gated threshold mechanism and provides negligible charge loss when the gain is switched (< 20 fC). A preintegration feature is also implemented in order to get rid of nonlinearity due to delays in the integration phase that could take place in a multi-ASIC system. The ASIC uses 5- and 3.3-V bias voltages, the overall power consumption being 280 mW. The ASIC was tested with a $12\times12$ SiPMs matrix coupled with a 3 inch LaBr 3 , providing good spectroscopic performances (2.6% at the 137 Cs photopeak emission energy of 662 keV), and was also tested irradiating the SiPMs with fast, bright NUV light pulses, in order to explore the ASIC wide range coverage while simulating the scintillation light emission of a lanthanum bromide crystal.
8 October 2020 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
The enhancement of a compact gamma-ray detection module for spectroscopy and imaging with machine learning for directional sensitivity is presented. In particular this development is targeted towards drone-based localization of radioactive sources in the environment. The unit is composed of a cylindrical monolithic scintillator crystal (3” × 3” LaBr3(Ce3++Sr2+)), read by an array of 144 solid-state SiPM detectors whose signals are conditioned by an integrated front-end. In addition to state-ofthe- art energy resolution (2.6% at 662 keV) and sub-centimeter spatial resolution in the reconstruction of the photon interaction point projected on the base, this portable unit enables the 2D angular localization of gamma sources on a plane parallel to the detectors array as a function of the reconstructed interaction point distribution, thanks to a decision tree. The classifier is compared with other techniques (k-NN, PCA) and optimized with 1000 splits. It runs in a 32-bit ARM micro-controller for real-time operation with a processing time of 2.75 μs per event, compatible with high gamma-ray counting rate (100 kcps) operation. Despite the absence of a collimator, classification is correct within ±30° for a single photon. Angular resolution of 0.5° and accuracy better than 2° are experimentally demonstrated (along with 0.8W power consumption and 3 kg weight), showing potential for identification of sources in the field.
Spotting radioactive material in waste is of paramount importance for environment protection. This is particularly challenging when orphan sources are hidden in scrap metal that shields their activity from the traditional detectors in the portals scanning incoming trucks. In order to address this issue, we present a wireless and compact SiPM-based gamma spectrometer compatible with strong magnetic fields (0.1 T) to be installed in the bore of the lifting electromagnets to scan reduced volumes of metal and thus achieve higher sensitivity. The microcontroller-based instrument provides 11% energy resolution (at 662 keV), an energy range from 60 keV to 1.5 MeV, a max. count rate of 30 kcps, a weight <1 kg, and a power consumption <1 W. The results of its extensive characterization in the laboratory and its validation in the field, including operation in a scrap yard as well as on a drone, are reported.
1 July 2019 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
We present a gamma-ray detection module for quantifying the boron neutron capture events that occur in Boron Neutron Capture Therapy (BNCT) and Neutron Capture Enhanced Particle Therapy (NCEPT). The goal of the module is to differentiate between the background prompt gamma peaks and the 478 keV neutron capture photopeak, in order to estimate the dose delivered to the patient. It is a compact module, coupling a large array of 64 SiPMs with a 2"×2" cylindrical LaBr3(Ce+Sr) scintillator crystal (73 ph/keV light yield, 25 ns decay time). The electronic front-end ASIC features low-noise processing of photodetector signals, while SiPMs pixellation and individual readout allow for position sensitivity in the crystal, although position estimation is not the object of this work. The module experimental characterization shows excellent energy resolution (2.7% FWHM at 662 keV), that allows to discriminate the neutron capture photons at 478 keV from the annihilation photons at 511 keV. The module features also an anti-coincidence circuit that provides a mechanism to distinguish and reject scintillation events created within specific temporal windows, thus enhancing the signal-to-background ratio of the spectrometer.
31 August 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment