David Setiadhi

Mr. David Setiadhi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Forces in Mechanics
Verified
Journal Article
Open access
TRTri Widodo Besar Riyadi
Tri Widodo Besar Riyadi
DSDavid Setiadhi
David Setiadhi
AAAgus Dwi Anggono
Agus Dwi Anggono
WSWaluyo Adi Siswanto
Waluyo Adi Siswanto
HAHussain H. Al-Kayiem
Hussain H. Al-Kayiem

5 January 2022 in Mechanical Engineering for Society and Industry
Verified
Journal Article
Open access
PDF file
AAAmarulloh Amarulloh
Amarulloh Amarulloh
HHHaikal Haikal
Haikal Haikal
NANugroho Tri Atmoko
Nugroho Tri Atmoko
BUBagus Radiant Utomo
Bagus Radiant Utomo
DSDavid Setiadhi
David Setiadhi
TRTri Widodo Besar Riyadi
Tri Widodo Besar Riyadi
This research aims to design an induction heating system and to investigate the effect of power supply and specimen diameter on specimen temperature and frequency on the coil. This study began with the development of an induction heating system that made use of circulating coolers outfitted with Thermoelectric Cooler Materials (TEC). It was intended to keep the temperature of the coil and the Printed Circuit Board (PCB) as low as possible. This study used AISI 4140 steel material with diameter variations of 7 mm, 14 mm, 21 mm, and 28 mm, with power levels of 60 W, 240 W, 540 W, and 960 W. The temperature was measured using a thermocouple connected to the specimen, and the frequency value obtained was measured using an oscilloscope. The research findings show that varying the applied power affects the frequency of the coil and the temperature of the specimen, with the higher the power, the faster the temperature of the specimen rises. The 60 W power can heat the specimen at an average temperature of 470°C and a frequency of 102 kHz. When the power variation is 960 W, the temperature in the specimen is 746°C, and the frequency is 110 kHz. On the temperature and frequency gradient pattern in the 0-600 s period, there are two stages, the first of which is ferromagnetic and the second of which is paramagnetic.

31 January 2024 in Mechanics Exploration and Material Innovation
Verified
Journal Article
Closed access
PDF file
AAAzka Ayatilhaq
Azka Ayatilhaq
PSPutu Hadi Setyarini
Putu Hadi Setyarini
MAMargono
Margono
DSDavid Setiadhi
David Setiadhi
Zn-based biodegradable implants were still relatively new, and much development was needed. This study added varying amounts of Mn to Zn alloys and analyzed their effect on corrosion rate. Corrosion testing was conducted electrochemically with a polarization test. The alloys were characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM). The effect of the additional Mn content was also observed through a hardness test. Zn-25Mn alloy had the lowest corrosion rate. The alloy, with the addition of certain levels of Mn, experienced the formation of the intermetallic phase MnZn13, which improved the mechanical properties and corrosion rate. This research provided insights into the biocompatibility of a biodegradable implant through in vivo and in vitro testing, allowing for further development of its results.

4 March 2026 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
DSDavid Setiadhi
David Setiadhi
KÇKadir Çavdar
Kadir Çavdar
CÖCüneyt Özakın
Cüneyt Özakın
KAKadir Ayas
Kadir Ayas
Ozone is increasingly recognized as an alternative sterilization agent for medical devices, offering high oxidative potential, broad-spectrum antimicrobial activity, and residue-free decomposition. Despite these advantages, its broader adoption remains constrained by ozone’s chemical instability and sensitivity to environmental conditions, complicating consistent sterilization outcomes, particularly for heat-sensitive devices and those with complex geometries. This review provides a critical evaluation of the four main ozone generation technologies used in medical device sterilization: corona discharge (CD), dielectric barrier discharge (DBD), ultraviolet-induced generation (UV-C), and electrochemical ozone production (EOP). The analysis focuses on how environmental parameters, material interactions, and reactor configurations influence ozone stability, delivery precision, and disinfection efficacy. Comparative findings indicate that while DBD systems provide superior energy efficiency and ozone yield, they require further optimization to mitigate NO x formation and manage thermal instability. CD systems, although widely used, face similar challenges and lower overall efficiency. EOP systems offer safer, NO x -free ozone generation but are limited by low output efficiency and scalability. UV-C systems, although contributing to ozone production through photodissociation, remain best suited as adjuncts in hybrid sterilization platforms. This review highlights key engineering strategies, identifies critical knowledge gaps, and outlines future research directions to advance ozone-based sterilization toward safe, efficient, and clinically relevant applications.