Polyisocyanurate (PIR) foam is a robust thermal insulation material utilized widely in the modern construction. In this work, the flammability of one representative example of this material was studied systematically using experiments and modeling. The thermal decomposition of this material was analyzed through thermogravimetric analysis, differential scanning calorimetry, and microscale combustion calorimetry. The thermal transport properties of the pyrolyzing foam were evaluated using Controlled Atmosphere Pyrolysis Apparatus II experiments. Cone calorimetry tests were also carried out on the foam samples to quantify the contribution of the blowing agent (contained within the foam) to its flammability, which was found to be significant. A complete pyrolysis property set was developed and was shown to accurately predict the results of all aforementioned measurements. The foam was also subjected to full-scale flame spread tests, similar to the Single Burning Item test. A previously developed modeling approach based on a coupling between detailed pyrolysis simulations and a spatially-resolved relationship between the total heat release rate and heat feedback from the flame, derived from the experiments on a different material in the same experimental setup, was found to successfully predict the evolution of the heat release rate measured in the full-scale tests on the PIR foam.
1 March 2017 in Journal of Loss Prevention in the Process Industries
Controlled fire experiments using a gas burner were previously conducted in a purpose-built, two-story, moderately air-tight residential structure to understand the effect of a heating, ventilating, and air conditioning (HVAC) system and door positions on the fire-induced environment. Temperatures, gas concentrations (oxygen, water vapor, carbon dioxide), and differential pressures were monitored throughout the structure. HVAC status (off vs. on) and stairwell door position of the fire room (open vs. closed) were varied for the experiments analyzed in this paper. In this study, Fire Dynamics Simulator (FDS) v. 6.7.9 was used to simulate these experiments. Experimental data quantifying the air tightness of the building and cold flowrates through HVAC vents were determined to be important to optimize leakages and HVAC loss coefficients for the simulation setup. Pressure development in the structure was predicted correctly to be higher on the first floor and lower in the basement, but the magnitude of steady-state pressure was underpredicted. The measured and predicted steady-state temperature distributions were statistically different for the cases with and without the HVAC on, regardless of the door position. FDS predicted gas transport through the HVAC duct network, and under-predicted temperature rise and water vapor content by about 9% and 10%, respectively, and over-predicted volumetric oxygen and carbon dioxide content by about 21% and 6%, respectively. Temperature rise prediction in the closed room, where the gas transport primarily occurred via the HVAC duct network, improved after including heat loss from the HVAC duct to the ambient.