Diomar Adonis Copetti Lima

Mr. Diomar Adonis Copetti Lima

Universidade Federal de Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
ÂSÂngelo Felipe Sartori
Ângelo Felipe Sartori
AMAdriano Peres de Morais
Adriano Peres de Morais
UNUlisses Chemin Netto
Ulisses Chemin Netto
DLDiomar Adonis Copetti Lima
Diomar Adonis Copetti Lima
DBDaniel Pinheiro Bernardon
Daniel Pinheiro Bernardon
WHWagner Seizo Hokama
Wagner Seizo Hokama
The IEC 61850 standard aims at digitization substations and provides interoperability between various Intelligent Electronic Device vendors. The digitization process is accompanied by several challenges related to data transmission on the ethernet network and the protection behavior under these conditions. Among the challenges, we can mention packet loss, delay, and duplicate frame, which occurs when the merging units (publisher) transmit the sampled values and, for some reason, these packets do not reach the subscriber or are duplicated. Nowadays, most Intelligent Electronic Device manufacturers block the protection function when some sampled value packets are corrupted. The effects of blocking protection when packet loss occurs under normal operating conditions do not cause significant problems. However, when a fault occurs, the corrupted packets can cause a delay in fault clearance, causing even more damage to the grid. The purpose of this article is to present the effects of corrupted sampled values on the performance of overcurrent protection. All the evaluations were performed in real time using the hardware-in-loop simulation approach with a commercial Intelligent Electronic Device. The OP5700 hardware platform from OPAL-RT, with the library “IEC 61850 Data Integrity Manipulation”, was used. The results show that corrupted sampled value frames affect the functioning of the protections.

15 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
DLDiomar Adonis Copetti Lima
Diomar Adonis Copetti Lima
DBDaniel Pinheiro Bernardon
Daniel Pinheiro Bernardon
AMAdriano P. Morais
Adriano P. Morais
AOAécio de Lima Oliveira
Aécio de Lima Oliveira
WHWagner S. Hokama
Wagner S. Hokama
ÂSÂngelo Felipe Sartori
Ângelo Felipe Sartori
The electrical power system is susceptible to several faults, which can cause the system to malfunction. Among these, the ones that occur in the busbars of substations stand out. The main bus of a substation can concentrate a large amount of power and many derivations to service electrical loads, making it an element of high importance for the reliability of the system. Although the buses have a low incidence of faults, they are considered critical elements of the electrical power system, as their operating output can cause a large number of forced outages. This situation makes the protection of this component of paramount importance. There are currently two widely used bus differential protection techniques: high-impedance and low-impedance bus differential protection. The second technique is more commonly used due to the possibility of sharing current transformers (CTs). However, the high cost and greater requirements for maintenance makes the differential protection of busbars in distribution or sub-transmission substations unfeasible. With the advent and implementation of the IEC 61850 standard, modern protection systems based on this standard offer significant advantages, such as lower expenses with installation, wiring, commissioning and maintenance; adaptable bus configuration; use of different CT ratios; considerably minimized susceptibility to CT saturation; lower risks of open secondary CT circuits and viability of implantation in distribution substations. The objective of this review is to present an overview of the works found in the literature on substation busbar differential protection, considering classical methods and those based on the IEC 61850 standard.

7 July 2023 in +ingenio - Revista de Ciencia Tecnología E Innovación
Verified
Journal Article
Open access
PDF file
DLDiomar Adonis Copetti Lima
Diomar Adonis Copetti Lima
FFFrancisco G. Fabrin
Francisco G. Fabrin
DBDaniel Pinheiro Bernardon
Daniel Pinheiro Bernardon
MOMario O. Oliveira
Mario O. Oliveira
RCRoberto J. Cabral
Roberto J. Cabral
Um dos grandes desafios das empresas distribuidoras de energia é manter o atendimento da demanda solicitadas por seus clientes. Desta forma o Operador Nacional do Sistema necessita realizar estudos complexos para atender a demanda de todo o sistema elétrico brasileiro. Desta forma se faz necessário o uso de ferramentas computacionais para auxiliar na tomada de decisão sobre o despacho de geração. Neste trabalho será utilizado o Método de Programação Dinâmica Determinística para ilustrar o comportamento das centrais geradoras frente a uma demanda (carga) solicitada pela rede.

5 February 2022 in +ingenio - Revista de Ciencia Tecnología E Innovación
Verified
Journal Article
Open access
PDF file
FFFrancisco Gasparin Fabrin
Francisco Gasparin Fabrin
DLDiomar Adonis Copetti Lima
Diomar Adonis Copetti Lima
ARAline Kieslich Rusch
Aline Kieslich Rusch
O conhecimento da resistência do solo onde será aplicado uma malha de aterramento e de fundamental importância para o circuito elétrico o qual será interligado, pois esse terá um papel fundamental na operação das proteções elétricas. O presente trabalho tem como objetivo apresenta uma análise em um período de 12 meses da resistência do solo comparando com a umidade e temperatura ambiente, para isso foi coletada dados semanalmente durante o período. Foi realizado um aterramento com 4 hastes do tipo Coperweld alinhadas em paralelo igualmente a uma distancia de 2 metros, o método de medição foi utilizado o de Queda de Potencial, conforme descrito na NB-15749, para a medição das resistências do solo foi utilizando o Terrômetro do modelo MRT-1520d. Com os resultados obtidos conclui-se que não há uma ligação direta da umidade e temperatura ambiente na resistência do solo.

5 February 2022 in +ingenio - Revista de Ciencia Tecnología E Innovación
Verified
Journal Article
Open access
PDF file
DLDiomar Adonis Copetti Lima
Diomar Adonis Copetti Lima
FFFrancisco Gasparin Fabrin
Francisco Gasparin Fabrin
DBDaniel Pinheiro Bernardon
Daniel Pinheiro Bernardon
MOMario O. Oliveira
Mario O. Oliveira
RCRoberto J. Cabral
Roberto J. Cabral
A necessidade de distribuir energia elétrica e manter a sua qualidade, faz com que empresas do setor elétrico estejam constantemente preocupadas com a configuração e expansão do Sistema Elétrico de Potência (SEP). Este trabalho visa apresentar uma metodologia para tomada de decisões, no que se refere a expansão do SEP, utilizando a otimização matemática. Será empregado para a simulação do SEP o software ANAREDE e o software Otimiza para a busca da melhor decisão.