Ulisses Chemin Netto

Dr. Ulisses Chemin Netto


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2024 in Electric Power Systems Research
Verified
Journal Article
Open access
AMAndré Felipe Silva Melo
André Felipe Silva Melo
Juan Manuel Roldan-FernandezJuan Manuel Roldan-Fernandez
Juan Manuel Roldan-Fernandez
Francisco Gonzalez-LongattFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
MBManuel Burgos-Payan
Manuel Burgos-Payan
UNUlisses Chemin Netto
Ulisses Chemin Netto

12 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
ÂSÂngelo Felipe Sartori
Ângelo Felipe Sartori
AMAdriano Peres de Morais
Adriano Peres de Morais
UNUlisses Chemin Netto
Ulisses Chemin Netto
DLDiomar Adonis Copetti Lima
Diomar Adonis Copetti Lima
DBDaniel Pinheiro Bernardon
Daniel Pinheiro Bernardon
WHWagner Seizo Hokama
Wagner Seizo Hokama
The IEC 61850 standard aims at digitization substations and provides interoperability between various Intelligent Electronic Device vendors. The digitization process is accompanied by several challenges related to data transmission on the ethernet network and the protection behavior under these conditions. Among the challenges, we can mention packet loss, delay, and duplicate frame, which occurs when the merging units (publisher) transmit the sampled values and, for some reason, these packets do not reach the subscriber or are duplicated. Nowadays, most Intelligent Electronic Device manufacturers block the protection function when some sampled value packets are corrupted. The effects of blocking protection when packet loss occurs under normal operating conditions do not cause significant problems. However, when a fault occurs, the corrupted packets can cause a delay in fault clearance, causing even more damage to the grid. The purpose of this article is to present the effects of corrupted sampled values on the performance of overcurrent protection. All the evaluations were performed in real time using the hardware-in-loop simulation approach with a commercial Intelligent Electronic Device. The OP5700 hardware platform from OPAL-RT, with the library “IEC 61850 Data Integrity Manipulation”, was used. The results show that corrupted sampled value frames affect the functioning of the protections.

1 January 2016 in Electric Power Systems Research
Verified
Journal Article
Closed access
UNUlisses Chemin Netto
Ulisses Chemin Netto
DGDiego de Castro Grillo
Diego de Castro Grillo
ILIvan Donisete Lonel
Ivan Donisete Lonel
EPEduardo Lorenzetti Pellini
Eduardo Lorenzetti Pellini
DCDenis Vinicius Coury
Denis Vinicius Coury

16 July 2026 in Electric Power Systems Research
Verified
Journal Article
Open access
BABryan A.S. Ambrósio
Bryan A.S. Ambrósio
GMGuido Rossetto Moraes
Guido Rossetto Moraes
RBRaul T. Bernardo
Raul T. Bernardo
UNUlisses Chemin Netto
Ulisses Chemin Netto
ATAugusto Tietz
Augusto Tietz
DIDiego Issicaba
Diego Issicaba


31 July 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
DMDuilio Cesar Mocelin
Duilio Cesar Mocelin
UNUlisses Chemin Netto
Ulisses Chemin Netto
GPGuilherme de Santi Peron
Guilherme de Santi Peron
Ohara Kerusauskas RayelOhara Kerusauskas Rayel
Ohara Kerusauskas Rayel
GMGuilherme MORITZ
Guilherme MORITZ
Reverse power flow (RPF) from distributed photovoltaic (PV) generation in low-voltage (LV) radial feeders threatens voltage regulation, transformer aging, and unidirectional protection. This paper presents a per-phase time-domain co-simulation platform that couples a procedural network generator, a Markov-chain irradiance model, ComStock/ResStock load profiles, a hybrid prosumer model with behind-the-meter battery storage, and a three-phase pandapower load-flow solver under Mosaik 3. A 432-scenario sweep (3 PV levels × 12 storage capacities × 12 seeds, 30 days at 15 min) shows that PV penetration is the dominant driver of RPF severity: the per-phase inversion time fraction rises from 13.0% to 35.4% as PV scales from 5 to 20 kWh per branch. Behind-the-meter storage is effective at moderate penetration but insufficient at high penetration: even 100 kWh reduces the inversion time fraction by only 29.4% at 20 kW. Root-cause analysis identifies two mechanisms invisible to aggregate steady-state models: households that produce more than they consume on average, and per-phase transformer imbalance. Storage shifts the composition of RPF, absorbing the aggregate surplus while exposing the phase-imbalance floor. Effective RPF elimination, therefore, requires simultaneously addressing both allocation-level and phase-level imbalance.