Domokos Meszéna

Dr. Domokos Meszéna

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2024 in Nature
Verified
Journal Article
Open access
PDF file
AKArjun R. Khanna
Arjun R. Khanna
WMWilliam Muñoz
William Muñoz
YKYoung Joon Kim
Young Joon Kim
YKYoav Kfir
Yoav Kfir
APAngelique C. Paulk
Angelique C. Paulk
ZWZiv M. Williams
Ziv M. Williams
Humans are capable of generating extraordinarily diverse articulatory movement combinations to produce meaningful speech. This ability to orchestrate specific phonetic sequences, and their syllabification and inflection over subsecond timescales allows us to produce thousands of word sounds and is a core component of language1,2. The fundamental cellular units and constructs by which we plan and produce words during speech, however, remain largely unknown. Here, using acute ultrahigh-density Neuropixels recordings capable of sampling across the cortical column in humans, we discover neurons in the language-dominant prefrontal cortex that encoded detailed information about the phonetic arrangement and composition of planned words during the production of natural speech. These neurons represented the specific order and structure of articulatory events before utterance and reflected the segmentation of phonetic sequences into distinct syllables. They also accurately predicted the phonetic, syllabic and morphological components of upcoming words and showed a temporally ordered dynamic. Collectively, we show how these mixtures of cells are broadly organized along the cortical column and how their activity patterns transition from articulation planning to production. We also demonstrate how these cells reliably track the detailed composition of consonant and vowel sounds during perception and how they distinguish processes specifically related to speaking from those related to listening. Together, these findings reveal a remarkably structured organization and encoding cascade of phonetic representations by prefrontal neurons in humans and demonstrate a cellular process that can support the production of speech.

11 September 2023 in Nature Protocols
Verified
Journal Article
Open access
PDF file
BCBrian Coughlin
Brian Coughlin
WMWilliam Muñoz
William Muñoz
YKYoav Kfir
Yoav Kfir
MYMichael J. Young
Michael J. Young
Domokos MeszénaDomokos Meszéna
Domokos Meszéna
APAngelique C. Paulk
Angelique C. Paulk
Neuropixels are silicon-based electrophysiology-recording probes with high channel count and recording-site density. These probes offer a turnkey platform for measuring neural activity with single-cell resolution and at a scale that is beyond the capabilities of current clinically approved devices. Our team demonstrated the first-in-human use of these probes during resection surgery for epilepsy or tumors and deep brain stimulation electrode placement in patients with Parkinson’s disease. Here, we provide a better understanding of the capabilities and challenges of using Neuropixels as a research tool to study human neurophysiology, with the hope that this information may inform future efforts toward regulatory approval of Neuropixels probes as research devices. In perioperative procedures, the major concerns are the initial sterility of the device, maintaining a sterile field during surgery, having multiple referencing and grounding schemes available to de-noise recordings (if necessary), protecting the silicon probe from accidental contact before insertion and obtaining high-quality action potential and local field potential recordings. The research team ensures that the device is fully operational while coordinating with the surgical team to remove sources of electrical noise that could otherwise substantially affect the signals recorded by the sensitive hardware. Prior preparation using the equipment and training in human clinical research and working in operating rooms maximize effective communication within and between the teams, ensuring high recording quality and minimizing the time added to the surgery. The perioperative procedure requires ~4 h, and the entire protocol requires multiple weeks.

2 January 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
KNKambiz Nanbakhsh
Kambiz Nanbakhsh
AIAhmad Shah Idil
Ahmad Shah Idil
CLCallum Lamont
Callum Lamont
CDCsaba Dücső
Csaba Dücső
ÖAÖmer Can Akgun
Ömer Can Akgun
VGVasiliki Giagka
Vasiliki Giagka
Silicon integrated circuits (ICs) are central to the next-generation miniature active neural implants, whether packaged in soft polymers for flexible bioelectronics or implanted as bare die for neural probes. These emerging applications bring the IC closer to the corrosive body environment, raising reliability concerns, particularly for chronic use. Here, we evaluate the inherent hermeticity of bare die ICs, and examine the potential of polydimethylsiloxane (PDMS), a moisture-permeable elastomer, as a standalone encapsulation material. For this aim, the electrical and material performance of ICs sourced from two foundries was evaluated through one-year accelerated in vitro and in vivo studies. ICs featured custom-designed test structures and were partially PDMS coated, creating two regions on each chip, uncoated “bare die” and “PDMS-coated”. During the accelerated in vitro study, ICs were electrically biased and periodically monitored. Results revealed stable electrical performance, indicating the unaffected operation of ICs even when directly exposed to physiological fluids. Despite this, material analysis revealed IC degradation in the bare regions. PDMS-coated regions, however, revealed limited degradation, making PDMS a suitable IC encapsulant for years-long implantation. Based on the new insights, guidelines are proposed that may enhance the longevity of implantable ICs, broadening their applications in the biomedical field.

1 July 2020 in Materials Science and Engineering: C
Verified
Journal Article
Open access
GMGergely Márton
Gergely Márton
ETEstilla Zsófia Tóth
Estilla Zsófia Tóth
LWLucia Wittner
Lucia Wittner
RFRichárd Fiáth
Richárd Fiáth
DPDomonkos Pinke
Domonkos Pinke
KTKinga Tóth
Kinga Tóth
The use of SU-8 material in the production of neural sensors has grown recently. Despite its widespread application, a detailed systematic quantitative analysis concerning its biocompatibility in the central nervous system is lacking. In this immunohistochemical study, we quantified the neuronal preservation and the severity of astrogliosis around SU-8 devices implanted in the neocortex of rats, after a 2 months survival. We found that the density of neurons significantly decreased up to a distance of 20 μm from the implant, with an averaged density decrease to 24 ± 28% of the control. At 20 to 40 μm distance from the implant, the majority of the neurons was preserved (74 ± 39% of the control) and starting from 40 μm distance from the implant, the neuron density was control-like. The density of synaptic contacts - examined at the electron microscopic level - decreased in the close vicinity of the implant, but it recovered to the control level as close as 24 μm from the implant track. The intensity of the astroglial staining significantly increased compared to the control region, up to 560 μm and 480 μm distance from the track in the superficial and deep layers of the neocortex, respectively. Electron microscopic examination revealed that the thickness of the glial scar was around 5-10 μm thin, and the ratio of glial processes in the neuropil was not more than 16% up to a distance of 12 μm from the implant. Our data suggest that neuronal survival is affected only in a very small area around the implant. The glial scar surrounding the implant is thin, and the presence of glial elements is low in the neuropil, although the signs of astrogliosis could be observed up to about 500 μm from the track. Subsequently, the biocompatibility of the SU-8 material is high. Due to its low cost fabrication and more flexible nature, SU-8 based devices may offer a promising approach to experimental and clinical applications in the future.

20 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AZA. Zátonyi
A. Zátonyi
Gabor OrbanGabor Orban
Gabor Orban
RMR. Modi
R. Modi
GMG. Márton
G. Márton
Domokos MeszénaDomokos Meszéna
Domokos Meszéna
ZFZoltán Fekete
Zoltán Fekete
Softening neural implants that change their elastic modulus under physiological conditions are promising candidates to mitigate neuroinflammatory response due to the reduced mechanical mismatch between the artificial interface and the brain tissue. Intracortical neural probes have been used to demonstrate the viability of this material engineering approach. In our paper, we present a robust technology of softening neural microelectrode and demonstrate its recording performance in the hippocampus of rat subjects. The 5 mm long, single shank, multi-channel probes are composed of a custom thiol-ene/acrylate thermoset polymer substrate, and were micromachined by standard MEMS processes. A special packaging technique is also developed, which guarantees the stable functionality and longevity of the device, which were tested under in vitro conditions prior to animal studies. The 60 micron thick device was successfully implanted to 4.5 mm deep in the hippocampus without the aid of any insertion shuttle. Spike amplitudes of 84 µV peak-to-peak and signal-to-noise ratio of 6.24 were achieved in acute experiments. Our study demonstrates that softening neural probes may be used to investigate deep layers of the rat brain.

6 March 2025 in Nature Methods
Verified
Journal Article
Closed access
PDF file
CWCharlie Windolf
Charlie Windolf
HYHan Yu
Han Yu
APAngelique C. Paulk
Angelique C. Paulk
Domokos MeszénaDomokos Meszéna
Domokos Meszéna
WMWilliam Muñoz
William Muñoz
EVErdem Varol
Erdem Varol