Gabor Orban

Dr. Gabor Orban

Microtechnology for Neuroelectronics, Italian Institute of Technology, Genoa, Liguria, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Materials Science and Engineering: C
Verified
Journal Article
Open access
GMGergely Márton
Gergely Márton
ETEstilla Zsófia Tóth
Estilla Zsófia Tóth
LWLucia Wittner
Lucia Wittner
RFRichárd Fiáth
Richárd Fiáth
DPDomonkos Pinke
Domonkos Pinke
KTKinga Tóth
Kinga Tóth
The use of SU-8 material in the production of neural sensors has grown recently. Despite its widespread application, a detailed systematic quantitative analysis concerning its biocompatibility in the central nervous system is lacking. In this immunohistochemical study, we quantified the neuronal preservation and the severity of astrogliosis around SU-8 devices implanted in the neocortex of rats, after a 2 months survival. We found that the density of neurons significantly decreased up to a distance of 20 μm from the implant, with an averaged density decrease to 24 ± 28% of the control. At 20 to 40 μm distance from the implant, the majority of the neurons was preserved (74 ± 39% of the control) and starting from 40 μm distance from the implant, the neuron density was control-like. The density of synaptic contacts - examined at the electron microscopic level - decreased in the close vicinity of the implant, but it recovered to the control level as close as 24 μm from the implant track. The intensity of the astroglial staining significantly increased compared to the control region, up to 560 μm and 480 μm distance from the track in the superficial and deep layers of the neocortex, respectively. Electron microscopic examination revealed that the thickness of the glial scar was around 5-10 μm thin, and the ratio of glial processes in the neuropil was not more than 16% up to a distance of 12 μm from the implant. Our data suggest that neuronal survival is affected only in a very small area around the implant. The glial scar surrounding the implant is thin, and the presence of glial elements is low in the neuropil, although the signs of astrogliosis could be observed up to about 500 μm from the track. Subsequently, the biocompatibility of the SU-8 material is high. Due to its low cost fabrication and more flexible nature, SU-8 based devices may offer a promising approach to experimental and clinical applications in the future.

27 February 2025 in Advanced Science
Verified
Journal Article
Open access
GAGian Nicola Angotzi
Gian Nicola Angotzi
MVMihály Vöröslakos
Mihály Vöröslakos
NPNikolas Perentos
Nikolas Perentos
JRJ. F. Ribeiro
J. F. Ribeiro
MVMatteo Vincenzi
Matteo Vincenzi
Luca BerdondiniLuca Berdondini
Luca Berdondini
Implantable active dense CMOS neural probes unlock the possibility of spatiotemporally resolving the activity of hundreds of single neurons in multiple brain circuits to investigate brain dynamics. Mapping neural dynamics in brain circuits with anatomical structures spanning several millimeters, however, remains challenging. Here, a CMOS neural probe advancing lateral sampling for mapping intracortical neural dynamics (both LFPs and spikes) in awake, behaving mice from an area >4 mm2 is demonstrated. By taking advantage of SiNAPS technology modularity, an 8‐shank probe with 1024 recording channels arranged in regular arrays of 128 electrodes/shank with an electrode pitch <30 µm is realized. Continuous low‐noise recordings (spikes with 6.67 ± 1.02 µVRMS) from all 1024 electrodes at 20 kHz/channel demonstrate the monitoring at high spatial and temporal resolution of a field of view spanning the 2D lattice of the entire mice hippocampal circuit, together with cortical and thalamic regions. This arrangement allows combining large population unit monitoring across distributed networks with precise intra‐ and interlaminar/nuclear mapping of the oscillatory dynamics.

18 December 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GMGergely Márton
Gergely Márton
Gabor OrbanGabor Orban
Gabor Orban
MKMarcell Kiss
Marcell Kiss
RFRichárd Fiáth
Richárd Fiáth
APAnita Pongrácz
Anita Pongrácz
IUIstván Ulbert
István Ulbert
Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs) makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG) signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks.

20 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AZA. Zátonyi
A. Zátonyi
Gabor OrbanGabor Orban
Gabor Orban
RMR. Modi
R. Modi
GMG. Márton
G. Márton
Domokos MeszénaDomokos Meszéna
Domokos Meszéna
ZFZoltán Fekete
Zoltán Fekete
Softening neural implants that change their elastic modulus under physiological conditions are promising candidates to mitigate neuroinflammatory response due to the reduced mechanical mismatch between the artificial interface and the brain tissue. Intracortical neural probes have been used to demonstrate the viability of this material engineering approach. In our paper, we present a robust technology of softening neural microelectrode and demonstrate its recording performance in the hippocampus of rat subjects. The 5 mm long, single shank, multi-channel probes are composed of a custom thiol-ene/acrylate thermoset polymer substrate, and were micromachined by standard MEMS processes. A special packaging technique is also developed, which guarantees the stable functionality and longevity of the device, which were tested under in vitro conditions prior to animal studies. The 60 micron thick device was successfully implanted to 4.5 mm deep in the hippocampus without the aid of any insertion shuttle. Spike amplitudes of 84 µV peak-to-peak and signal-to-noise ratio of 6.24 were achieved in acute experiments. Our study demonstrates that softening neural probes may be used to investigate deep layers of the rat brain.

22 May 2014 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
GMGergely Márton
Gergely Márton
MKMarcell Kiss
Marcell Kiss
Gabor OrbanGabor Orban
Gabor Orban
APAnita Pongrácz
Anita Pongrácz
IUIstván Ulbert
István Ulbert

24 April 2023
Verified
Conference Paper
Closed access
APAlberto Perna
Alberto Perna
JRJoão F. Ribeiro
João F. Ribeiro
Gabor OrbanGabor Orban
Gabor Orban
MVMatteo Vincenzi
Matteo Vincenzi
FBFabio Boi
Fabio Boi
LBLuca Berdondini
Luca Berdondini
Tissue penetrating neural probes implementing high-density microelectrode arrays constitute a key tool of modern neuroscience. One of the main limitations of current probes to achieve chronically stable intracortical neural interfacing, is the biological reaction that they onset in the brain. Such foreign body reaction (FBR) is initiated by the mechanical tissue damage that the probes cause during their insertion, which is expected to be correlated with the force required to perform the implantation. One potential strategy to improve the integration of tissue penetrating high-density neural probes within brain tissue is to optimize their size and geometry in order to minimize acute tissue damage and Blood Brain Barrier (BBB) disruption. This strategy is foreseen to yield a more favorable postsurgical environment, reducing the extent of FBR in a chronic setting. In this context, the force required for the insertion of tissue penetrating neural probes can be used as an objective metric to assess the extent of acute tissue damage they induce. This paper reports preliminary findings on the impact of Complementary Metal Oxide Semiconductor (CMOS) probe geometrical parameters on insertion force, with a particular focus on the importance of tip size and shape on the dimpling of brain tissue before penetration.