Domenico Tigani

Dr. Domenico Tigani

Maggiore Hospital
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2020 in Cells
Verified
Journal Article
Open access
PDF file
AMAntoniel Manuela
Antoniel Manuela
Francesco TrainaFrancesco Traina
Francesco Traina
LMLuciano Merlini
Luciano Merlini
DADavide Andrenacci
Davide Andrenacci
DTDomenico Tigani
Domenico Tigani
SSStefano Squarzoni
Stefano Squarzoni
Mutations in collagen VI genes cause two major clinical myopathies, Bethlem myopathy (BM) and Ullrich congenital muscular dystrophy (UCMD), and the rarer myosclerosis myopathy. In addition to congenital muscle weakness, patients affected by collagen VI-related myopathies show axial and proximal joint contractures, and distal joint hypermobility, which suggest the involvement of tendon function. To gain further insight into the role of collagen VI in human tendon structure and function, we performed ultrastructural, biochemical, and RT-PCR analysis on tendon biopsies and on cell cultures derived from two patients affected with BM and UCMD. In vitro studies revealed striking alterations in the collagen VI network, associated with disruption of the collagen VI-NG2 (Collagen VI-neural/glial antigen 2) axis and defects in cell polarization and migration. The organization of extracellular matrix (ECM) components, as regards collagens I and XII, was also affected, along with an increase in the active form of metalloproteinase 2 (MMP2). In agreement with the in vitro alterations, tendon biopsies from collagen VI-related myopathy patients displayed striking changes in collagen fibril morphology and cell death. These data point to a critical role of collagen VI in tendon matrix organization and cell behavior. The remodeling of the tendon matrix may contribute to the muscle dysfunction observed in BM and UCMD patients.

20 September 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
DTDomenico Tigani
Domenico Tigani
LLLuigigiuseppe Lamattina
Luigigiuseppe Lamattina
NPNicole Puteo
Nicole Puteo
CDCesare Donadono
Cesare Donadono
LBLorenzi Banci
Lorenzi Banci
AAAndrea Assenza
Andrea Assenza
In total joint replacement, early aseptic loosening of implants caused by inadequate initial fixation and late aseptic loosening due to stress shielding-related periprosthetic bone remodeling are the main causes of failure. Over the last two decades, additive manufacturing has been revolutionizing the design of cementless orthopaedic implants by enabling biomimetic, highly porous titanium structures that enhance bone ingrowth and osseointegration while reducing stress shielding. The synergy between optimized selective laser-melted highly porous titanium bearing components, ceramic-coated titanium articular surfaces, and vitamin E-stabilized polyethylene liners delivers several benefits essential for implant longevity: reliable initial fixation, improved biological fixation, reduced bone resorption caused by stress shielding, and lower osteolytic reactivity. These benefits have encouraged the synergetic use of these technologies in joint replacement in novel clinical applications. In recent years, novel off-the-shelf, 3D-printed, highly porous titanium implants have been introduced into hip and knee arthroplasty. These newly introduced implants appear to offer an innovative and promising solution, and are particularly indicated for young active patients, elderly patients with osteoporotic bones, and in complex cases. Future clinical research should confirm these novel implants’ superior results in comparison to the current state of the art in cementless joint replacement. The possibility of extending these technologies in the future to other clinical applications such as partial knee prosthesis is discussed.

27 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
Saverio AffatatoSaverio Affatato
Saverio Affatato
ECEmanuela Castiello
Emanuela Castiello
LALuca Amendola
Luca Amendola
SCSaverio Comitini
Saverio Comitini
JPJean-Louis Prudhon
Jean-Louis Prudhon
DTDomenico Tigani
Domenico Tigani
Revision of large-diameter, monoblock acetabular components for both hip resurfacing arthroplasty and metal-on-metal (MoM) total hip arthroplasty (THA) is correlated to a high amount of complications. For this reason, performing a limited revision by conversion to a dual mobility (DM) without acetabular component exchange has been proposed in order to limit these complications. Although DM bearing offers an easy solution avoiding the intraoperative and time-associated complications, concern about polyethylene wear and stability remains due to the difference regarding the design, the coverage angle and the clearance of the two implants. In order to evaluate the performance of this new solution with the new material to prevent the possibility of failure it is essential to conduct a review of the literature A qualitative systematic review of the literature has been conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search of PubMed, EMBASE, Google Scholar, and Scopus for English and French articles between January 2000 and October 2019 was performed, with the primary objective of finding articles about dual mobility bearing coupling with large metal-on-metal cup in the case of hip revision procedure. Various combinations of the key words were used in the search strategy. Thirteen articles with DM bearing mated with MoM cup were analyzed. Of the 130 hip revisions selected, with a follow-up from 6 to 53 months, there were a total of 14 with complications (10.77%): four true dislocations (3.08%); six intra-prosthetic dislocations (IPD, 4.6%), two of which presented plastic deformation and polyethylene wear; four other complications (3.08%), included a cup osteolysis, a clicking noise, a superficial infection and a periprosthetic fracture. All the mentioned true dislocations occurred during the first month while IPDs appeared during the first two years from the index revision. In conclusion, according to the literature analyzed, we can stress that the concerns and doubts about mating a DM bearing with large MoM cup cannot be dissolved. It has been pointed out that a DM bearing is not designed for a MoM cup; it is not mechanically tested on MoM cups, which presents different clearance and coverage angles. Predictable complications may occur, such as IPD, polyethylene wear and true dislocation. These complications have been reported at an even higher rate than they were in the eighties, when the first generation of DM implants were of a lower quality of polyethylene and the characteristic of the design was less optimal than modern ones.

20 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Silvio CaravelliSilvio Caravelli
Silvio Caravelli
Giammarco GardiniGiammarco Gardini
Giammarco Gardini
CPCamilla Pungetti
Camilla Pungetti
PGPaolo Gentile
Paolo Gentile
Carlo PerisanoCarlo Perisano
Carlo Perisano
Massimiliano MoscaMassimiliano Mosca
Massimiliano Mosca
Introduction: Calcaneal fractures (CF) are the most common tarsal fractures, representing up to 75% of foot fractures and 2% of all fractures. The aim of this retrospective study is to analyze fixation with Kirschner wires through a mini-invasive approach and dedicated plate and screws through an extended approach at long-term follow-up. Materials and Methods: Patients were radiographically and clinically evaluated at final follow-up, by using the validated American Orthopedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score for the clinical–functional assessment, the Short-Form 12 (SF-12) for the physical and psychological domain assessment, and the Visual Analog Scale (VAS) for pain. Results: In total, 38 patients (42 CF) met the inclusion criteria and were retrospectively evaluated and divided into two groups (Kirschner group and plate group) consisting of 19 patients each. The overall mean follow-up was 59.4 ± 11.8 months. The average values of the post-operative clinical outcomes of the two groups KG and PG were, respectively, 70.7 ± 11.9 and 70.1 ± 10.9 (AOFAS), 45.7 ± 6.8 and 46.5 ± 10.8 (SF-12 PCS), 54.7 ± 9.9 and 50.9 ± 11.8 (SF-12 MCS) at the final follow-up. Conclusions: The present study showed that in the cases analyzed, the two surgical approaches used for the treatment of CF achieved comparable clinical outcomes. The only substantial difference found between the two groups of patients was the re-intervention rate that afflicted them.

17 April 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
DTDomenico Tigani
Domenico Tigani
LSLudovica Solito
Ludovica Solito
SSStefano Stallone
Stefano Stallone
CLCorrado Maria Leonida
Corrado Maria Leonida
TDTommaso Dieterich
Tommaso Dieterich
GMGiuseppe Melucci
Giuseppe Melucci
The use of 3D-printed highly porous titanium acetabular cups in total hip arthroplasty (THA) is increasing. The porosity and mechanical properties of such highly porous titanium structures mimic those of natural cancellous bone, possibly allowing biological implant fixation to be improved. Recently, a 3D-printed highly porous Dual Mobility (DM) monobloc construct fully manufactured using Ti6Al4V alloy, with a titanium–niobium nitride (TiNbN) ceramic coating on the articular side to allow articulation against the mobile liner by improving the titanium vs. polyethylene tribological behavior, was introduced in THA. To the best of our knowledge, this is the first highly porous titanium monobloc DM implant on the market. The reasons for using a Ti alloy highly porous DM are multifarious: to prevent any possible adverse reactions due to the corrosion of Cobalt–Chromium–Molybdenum Alloy (CoCrMo) and Stainless Steel (SS) implants and to improve implant primary and secondary stability, particularly in cases of poor bone quality. Finally, with the introduction of an inner TiNbN ceramic coating surface, it was possible to overcome the poor tribological quality of titanium. Another interesting characteristic is this material’s higher implant radiolucency, which might facilitate the radiographic assessment of cup orientation, which can, in turn, facilitate the detection of any intraprosthetic dislocation (IPD) and the measurement of polyethylene wear, which is very important in the study of the durability of THA.

25 July 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
DTDomenico Tigani
Domenico Tigani
ECEnrico Ferranti Calderoni
Enrico Ferranti Calderoni
MBMatteo Berti
Matteo Berti
SCSaverio Comitini
Saverio Comitini
LALuca Amendola
Luca Amendola
GMGiuseppe Melucci
Giuseppe Melucci
Background: Total knee arthroplasty (TKA) for poliomyelitis patients is controversial due to its higher complication rate compared with that of TKA for osteoarthritis. In this study we evaluated the results, at a minimum of 10 years, of a consecutive series of third-generation rotating hinge total knee arthroplasties (RHKs) in patients affected by poliomyelitis. Methods: We conducted a retrospective analysis of 14 patients (15 TKA) performed between January 2000 and October 2021 that underwent a third-generation rotating hinge arthroplasty (Nex Gen RHK Zimmer). The clinical results using the American Knee Society Score (AKSS) were evaluated at an average follow-up of 154 months (min 120–max 216 months). Result: Of the 15 cases, 2 were lost at follow-up and 1 was excluded by the final evaluation due to infection. Of the remaining 12 cases at the final follow-up, the average AKKS clinical score improved from 30.08 points preoperatively, to 78.83 points postoperatively, while the average AKKS function score improved from 29.17 points to 56.25 points. We report only one intraoperative complication consisting of a femoral fracture at the tip of the stem, and a case of patellar fracture occurred 3 months after the index procedure. The presence of radiolucent lines was sporadic, while radiosclerotic lines were commonly visible around the stem extension, predominantly at the tip. Conclusions: The third generation of rotating hinge knee replacement has proved to be effective in polio patients, improving clinical and functional scores, and no cases of mechanical failure occurred.