Damage detection is the basis of the damage identification task in Structural Health Monitoring. A good damage detection process can ensure the adequate work of a SHM System because allows to know early information about the presence of a damage in a structure under evaluation. However this process is based on the premise that all sensors are well installed and they are working properly, however, it is not true all the time. Problems such as debonding, cuts and the use of the sensors under different environmental and operational conditions result in changes in the vibrational response and a bad functioning in the SHM system. As a contribution to evaluate the state of the sensors in a SHM system, this paper describes a methodology for sensor fault detection in a piezoelectric active system. The methodology involves the use of PCA for multivariate analysis and some damage indices as pattern recognition technique and is tested in a blade from a wind turbine where different scenarios are evaluated including sensor cuts and debonding.
1 May 2020 in IOP Conference Series: Materials Science and Engineering
Knowing the quality of concrete is very important, because this type of material is part of the design and implementation of most structures such as bridges, buildings, tunnels, among others, in this investigation non-destructive tests were carried out on test specimens of using ultrasound, which were designed and developed in the concrete laboratory at Santo Tomas University in Bogotá D.C. taking into account for its preparation a dosage of the estimated concrete mixture in order to obtain specimens with a compressive strength of 3500psi, 2500psi and 1500psi, in such a way, the specimens were allowed to cure for a period of 28 days, ensuring that they achieved their maximum compression strength. As mentioned above, non-destructive ultrasound tests were applied in order to determine the quality of the manufactured concrete specimens, thus, an ultrasound system is proposed that makes it possible to pass an acoustic wave through a concrete specimen, this was proposed with the purpose of measuring the velocity with which the wave passes in the volume of this material, known as the ultrasonic pulse velocity. Therefore, the respective velocities for each of the concrete specimens were measured, thus finding a relationship between the ultrasonic pulse velocity and the compressive strength, which finally makes possible the evaluation of the manufactured concrete specimens.
20 January 2022 in International Journal of Technology
The noninvasive technique of ultrasonic pulse rate (UPV) is increasingly used in the evaluation of the quality of concrete, providing information about the integrity of structures and preventing possible disasters. Therefore, for its direct application, it is necessary to have a prior correlation between the noninvasive UPV technique and the invasive uniaxial compression resistance (UCS) assay. While correlations have been determined by various authors, each has been given specific conditions and guidelines by the authors because there is no standardized way to perform the correlations. Rather, there are only experimental tests that have generated experimental correlations—both linear and logarithmic—with different graphic shapes. Therefore, this research aims, first, to validate the aforementioned relationship, which allows the compressure resistance of concrete (f'c) to be determined for a given design of concrete mixtures following the American Concrete Institute (ACI. 211.1.). Second, it aims to determine the most accurate trend and the possibly correct form of the correlation plot between the UPV and UCS. In the first instance, 15 plain concrete specimens were designed with an f’c of 28 MPa, whose dosage was carried out following the method of ACI. 211.1. Then, UPV and UCS tests were performed according to regulations in the first 28 days of curing the specimens. Finally, a logarithmic correlation was obtained between the UPV values and the values of the invasive tests for the UCS of concrete. A graphical analysis with some existing correlations of other investigations was then performed, and a similarity in the logarithmic tendency, with a coefficient of determination greater than that of the linear trend, was observed.
This work analyzes the photovoltaic potential of four cities in Colombia—Bogotá, Cúcuta, Manizales, and Pasto—using information collected in situ and data mining strategies. The methodology of this study is based on clustering techniques implemented in MATLAB® software. Two comparison algorithms are presented: K-means, Fuzzy C-means, and an additional visualization algorithm, i.e., Principal Component Analysis (PCA), which supports results analysis. This article explores published studies regarding data mining and it describes the previously mentioned algorithms. On the other hand, the most relevant results and discussion, which are related to the feasibility of implementation of micro-grids, are determined by calculating the Capacity Factor.
25 October 2018 in IOP Conference Series: Materials Science and Engineering
The present work has been made to find out the relationship between the efficiency of two types of photovoltaics panels, monocrystalline and polycrystalline, and the weather variation in the city of Bogota-Colombia. The power generated of two photovoltaic panels, one monocrystalline and one polycrystalline, were collected for one month, 24 hours in condition of variant weather. At the same time, it was implemented a weather station that registered the variations of climatic variables like wind speed, temperature, humidity, irradiance and rainfall, to relate them with the generated power of each photovoltaic panel. Once with this information collected it a study was made with all the correlated variables through of the statistic tool PCA (Principals Components Analysis) where it was seen the impact of each climatic variable over the generated power in both panels and therefore its impact over the efficiency.