Emerson Luís Yoshio Hara

Dr. Emerson Luís Yoshio Hara

Federal University of Paraná, Curitiba, Paraná, Brazil
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2017 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Closed access
APAngela Maria Palacio-Cortés
Angela Maria Palacio-Cortés
ISIsadora de Lourdes Signorini-Souza
Isadora de Lourdes Signorini-Souza
Emerson Luís Yoshio HaraEmerson Luís Yoshio Hara
Emerson Luís Yoshio Hara
Geonildo Rodrigo DisnerGeonildo Rodrigo Disner
Geonildo Rodrigo Disner
DRDebora Rebechi
Debora Rebechi
MNMario Antônio Navarro-Silva
Mario Antônio Navarro-Silva

7 December 2022 in Molecules
Verified
Journal Article
Open access
PDF file
GSGustavo Sánchez-Duque
Gustavo Sánchez-Duque
JLJUAN JOSE LOZADA
JUAN JOSE LOZADA
Emerson Luís Yoshio HaraEmerson Luís Yoshio Hara
Emerson Luís Yoshio Hara
MGMarco Tadeu Grassi
Marco Tadeu Grassi
MRMilton Rosero-Moreano
Milton Rosero-Moreano
JRJhon Jairo Rios-Acevedo
Jhon Jairo Rios-Acevedo
A new sorbent material based on modified clay with ionic liquid immobilized into an agarose film was developed as part of this study. It was applied to determine organochlorine pollutants, like disinfection byproducts, through headspace solid-phase microextraction-gas chromatography-electron capture detection (HS-SPME-GC-ECD). The disinfection byproducts determined in this study were used as model molecules because they were volatile compounds, with proven severe effects on human health. Their presence in aquatic environments is in trace concentrations (from pg L−1 to mg L−1). They are classified as emergent pollutants and their determination is a challenge for analytical chemists. The parameters which affected the extraction efficiency, i.e., number and distance between SPME discs, salt concentration, the temperature of extraction, extraction time, and desorption time, were optimized. A wide linear dynamic range of 10–1000 ng mL−1 and coefficients of determination better than 0.997 were achieved. The limits of detection and the limits of quantitation were found in the ranges of (1.7–3.7) ng mL−1 and (5.6–9.9) ng mL−1, respectively. The precision, expressed as relative standard deviation (RSD), was better than 8%. The developed sorbent exhibits good adsorption affinity. The applicability of the proposed methodology for the analysis of trihalomethanes in environmental and water samples showed recoveries in the range of 86–95%. Finally, the newly created method fully complied with the principles of green chemistry. Due to the fact that the sorbent holder was made of agarose, which is a wholly biodegradable material, sorbent clay is a widespread material in nature. Moreover, the reagents intercalated into the montmorillonite are new green solvents, and during the whole procedure, low amounts of organic solvents were used.

1 July 2018 in Química Nova
Verified
Journal Article
Open access
DRDaniel Annunciação Luiz Rodrigues
Daniel Annunciação Luiz Rodrigues
FAFernanda Almeida
Fernanda Almeida
Emerson Luís Yoshio HaraEmerson Luís Yoshio Hara
Emerson Luís Yoshio Hara
MGMarco Tadeu Grassi
Marco Tadeu Grassi
FFFernando Fabriz
Fernando Fabriz

1 January 2021 in Journal of the Brazilian Chemical Society
Verified
Journal Article
Closed access
TWTiago Wacheski
Tiago Wacheski
Emerson Luís Yoshio HaraEmerson Luís Yoshio Hara
Emerson Luís Yoshio Hara
BSBarbara Soares
Barbara Soares
BSBruno Silva
Bruno Silva
GAGilberto Abate
Gilberto Abate
MGMarco Tadeu Grassi
Marco Tadeu Grassi

1 January 2018 in Current Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
Emerson Luís Yoshio HaraEmerson Luís Yoshio Hara
Emerson Luís Yoshio Hara
CSCesar Alexandro da Silva
Cesar Alexandro da Silva
RSRogério da Silva Souza
Rogério da Silva Souza
ACAline Garus Saint Clair Colimo
Aline Garus Saint Clair Colimo
MGMarco Tadeu Grassi
Marco Tadeu Grassi
Background: PBDEs consist of synthetic chemicals frequently employed to help reducing or avoiding flame spread in a fire. As reactive flame retardants, they are covalently bound to the polymeric matrix of various domestic products. These compounds have drawn attention due to their large-scale production and use, and numerous papers have reported their presence as well as persistence in water, soil, sediment and atmospheric air, even in remote areas. The aim of this work was to develop a low cost and environmentally friendly analytical protocol to determine PBDEs in riverine sediment samples. Methods: First step consisted of optimizing instrumental parameters of GC-MS to improve the detectability of the target compounds. Then, factorial experiment designs at two levels, 2(3) and 2(4), were applied to evaluate the effects of these parameters on the GC-MS signal responses. The extraction of PBDE from the samples and the clean-up of the extracts were performed in order to ensure efficiency and low consumption of time, power and reagents. Results: GC-MS optimization allowed reduced running time associated with effective PBDE congeners separation and detection, when compared to the official proposed method. Recovery tests of extraction and clean-up steps presented satisfactory values when compared to the costly US EPA methodology. Conclusion: The results allow us to conclude that the proposed methodology is an efficient alternative for the determination of PBDEs from riverine sediments. Its advantage is related to the reduced consumption of time, power and reagents.

2 June 2021 in Brazilian Journal of Analytical Chemistry
Verified
Journal Article
Closed access
Emerson Luís Yoshio HaraEmerson Luís Yoshio Hara
Emerson Luís Yoshio Hara
BSBarbara Soares
Barbara Soares
ASAdriano Santos
Adriano Santos
BSBruno Santos
Bruno Santos
GAGilberto Abate
Gilberto Abate
MGMarco Tadeu Grassi
Marco Tadeu Grassi
Reports on the determination of emerging contaminants (EC) in aqueous samples have been increasingly common. Due to the low levels of concentration of the analytes as well as the complexity of this matrix, the analysis is done preferably by liquid chromatography (LC). Owing to the polar character of most of the EC determination by gas chromatography is deprecated. One way to overcome this barrier is through derivatization, which, in some cases, can be a lengthy step, presents risks to the analyst as well as to the environment due to the toxicity of the derivatizing agent, and, thus, ends up favoring the use of LC. An analytical protocol was developed in this work to increase the efficiency of derivatization in a shorter reaction time for the determination of ibuprofen, 4-octylphenol, 4-nonylphenol, triclosan, bisphenol A, diclofenac, estrone, 17-β-estradiol, estriol, coprostanol, and cholesterol. The proposal then was to carry out the silylation reaction of the analytes with the aid of a domestic microwave oven. The results indicated that the use of the device provided an increase in the efficiency of the reaction, due to the homogeneous heating of the solution. Besides, there was a significant decrease in the derivatization time of the analytes from 30 min to 5 min. Additionally, through a design of experiments (DOE), it was possible to perceive the influence of some instrumental parameters of GC-MS, such as temperature, pressure intensity, and pressure pulse time in the injector on the detectability of the investigated analytes. This study allowed a satisfactory separation of the analytes and an average increase in their areas of up to 35%. These aspects made it possible to obtain an analytical method with limits for the detection and quantification of EC between 0.03-11.00 ng mL-1 and 0.10-33.35 ng mL-1, respectively, and uncertainties below 9%. The developed method was applied in the determination of the analytes in coastal seawater and the determined concentrations varied from 0.24 ng L-1 for estriol and 43.60 ng L-1 for cholesterol. Thus, the improvement of the silylation reaction, combined with the strategy of instrumental optimization, proved to be simple, efficient, and fast, as well as being a comparable alternative to liquid chromatography.