Eugen Chiriac

Mr. Eugen Chiriac

National Institute for Research and Development in Microtechnologies, Bucharest, Bucureşti, Romania
+1

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Octavian Gabriel SimionescuOctavian Gabriel Simionescu
Octavian Gabriel Simionescu
Marius Andrei AvramMarius Andrei Avram
Marius Andrei Avram
BABianca Adiaconita
Bianca Adiaconita
PPPetruta Preda
Petruta Preda
CPCatalin Corneliu Parvulescu
Catalin Corneliu Parvulescu
MAMarioara Avram
Marioara Avram
The progress of advanced materials has invoked great interest in promising novel biosensing applications. Field-effect transistors (FETs) are excellent options for biosensing devices due to the variability of the utilized materials and the self-amplifying role of electrical signals. The focus on nanoelectronics and high-performance biosensors has also generated an increasing demand for easy fabrication methods, as well as for economical and revolutionary materials. One of the innovative materials used in biosensing applications is graphene, on account of its remarkable properties, such as high thermal and electrical conductivity, potent mechanical properties, and high surface area to immobilize the receptors in biosensors. Besides graphene, other competing graphene-derived materials (GDMs) have emerged in this field, with comparable properties and improved cost-efficiency and ease of fabrication. In this paper, a comparative experimental study is presented for the first time, for FETs having a channel fabricated from three different graphenic materials: single-layer graphene (SLG), graphene/graphite nanowalls (GNW), and bulk nanocrystalline graphite (bulk-NCG). The devices are investigated by scanning electron microscopy (SEM), Raman spectroscopy, and I-V measurements. An increased electrical conductance is observed for the bulk-NCG-based FET, despite its higher defect density, the channel displaying a transconductance of up to ≊4.9×10−3 A V−1, and a charge carrier mobility of ≊2.86×10−4 cm2 V−1 s−1, at a source-drain potential of 3 V. An improvement in sensitivity due to Au nanoparticle functionalization is also acknowledged, with an increase of the ON/OFF current ratio of over four times, from ≊178.95 to ≊746.43, for the bulk-NCG FETs.

4 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
BABianca Adiaconita
Bianca Adiaconita
TBTiberiu Burinaru
Tiberiu Burinaru
AEAna-Maria Enciu
Ana-Maria Enciu
PPPetruta Preda
Petruta Preda
ECEugen Chiriac
Eugen Chiriac
Marius Andrei AvramMarius Andrei Avram
Marius Andrei Avram
The selective and rapid detection of tumor cells is of critical consequence for the theragnostic field of tumorigenesis; conventional methods, such as histopathological diagnostic methods, often require a long analysis time, excessive analytical costs, complex operations, qualified personnel and deliver many false-positive results. We are considering a new approach of an electrochemical biosensor based on graphene, which is evidenced to be a revolutionary nanomaterial enabling the specific and selective capture of tumor cells. In this paper, we report a biosensor fabricated by growing vertically aligned graphene nanosheets on the conductive surface of interdigitated electrodes which is functionalized with anti-EpCAM antibodies. The dielectric signature of the three types of tumor cells is determined by correlating the values from the Nyquist and Bode diagram: charge transfer resistance, electrical double layer capacity, Debye length, characteristic relaxation times of mobile charges, diffusion/adsorption coefficients, and variation in the electrical permittivity complex and of the phase shift with frequency. These characteristics are strongly dependent on the type of membrane molecules and the electromagnetic resonance frequency. We were able to use the fabricated sensor to differentiate between three types of tumor cell lines, HT-29, SW403 and MCF-7, by dielectric signature. The proposed evaluation method showed the permittivity at 1 MHz to be 3.63 nF for SW403 cells, 4.97 nF for HT 29 cells and 6.9 nF for MCF-7 cells.

24 March 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
CMCatalin Marculescu
Catalin Marculescu
PPPetruta Preda
Petruta Preda
TBTiberiu Burinaru
Tiberiu Burinaru
ECEugen Chiriac
Eugen Chiriac
BABianca Adiaconita
Bianca Adiaconita
MAMarioara Avram
Marioara Avram
In recent research, 3D printing has become a powerful technique and has been applied in the last few years to carbon-based materials. A new generation of 3D-printed electrodes, more affordable and easier to obtain due to rapid prototyping techniques, has emerged. We propose a customizable fabrication process for flexible (and rigid) carbon-based biosensors, from biosensor design to printable conductive inks. The electrochemical biosensors were obtained on a 50 µm Kapton® (polyimide) substrate and transferred to a 500 µm PDMS substrate, using a 3D-extrusion-based printing method. The main features of our fabrication process consist of short-time customization implementation, fast small-to-medium batch production, ease of electrochemical spectroscopy measurements, and very good resolution for an extrusion-based printing method (100 µm). The sensors were designed for future integration into a smart wound dressing for wound monitoring and other biomedical applications. We increased their sensibility with electro-deposited gold nanoparticles. To assess the biosensors’ functionality, we performed surface functionalization with specific anti-N-protein antibodies for SARS-CoV 2 virus, with promising preliminary results.

20 June 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
ECEugen Chiriac
Eugen Chiriac
MAMarioara Avram
Marioara Avram
CBCorneliu Balan
Corneliu Balan
The evolution of an interface between two immiscible liquids in a three-branch symmetric microchannel is numerically and experimentally investigated. The main goals of the paper are to correlate the numeric data with the experimental results for the tested flow case and to assess the quality of the VOF procedure to trace the interface using the Fluent commercial code. The focus of the experiments was to characterize the dynamics of the oil–water interface formed in the vicinity of the bifurcation, at the entrance in the main microchannel of 400 microns width and 50 microns height. The oil core surrounded by water is visualized and micro-PIV measurements are performed in water. Experimental results qualitatively and quantitatively confirm the 3D numerical simulations. We propose the present investigated flow as a benchmark case for the study of the interface in a branching microchannel geometry.

7 October 2020
Verified
Conference Paper
Closed access
ECEugen Chiriac
Eugen Chiriac
MAMarioara Avram
Marioara Avram
CBCorneliu Balan
Corneliu Balan
Over the years several methods were used to separate cells within a microfluidic device such as cavities, with vortex microfluidics method, or cell trapping mechanisms using size filters. However, one of the methods that is widely used to separate cancer cells from blood cells is the dielectrophoresis. In this work we employ the numerical code COMSOL Multiphysics for a dielectrophoretic separation of CTCs (circulating tumor cells) from RBCs (red blood cells) in a 3D microchannel. The microfluidic device is composed of one inlet and three outlets. The non-uniform alternative electric field is generated using interdigitated electrodes and it separates the cells within the device to the corresponding outlet. The electric field frequency was set to 100kHz. For this paper, one single CTC line is selected MDA-MB-231, breast cancer cells. The CTCs and the RBCs are considered in an ideal way in the simulation as spheres, but with the afferent characteristics. This work can be extended to testing multiple CTC lines at various flow velocities and electric field frequencies.

30 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ELEvdochim Lucian
Evdochim Lucian
ECEugen Chiriac
Eugen Chiriac
MAMarioara Avram
Marioara Avram
Lidia DobrescuLidia Dobrescu
Lidia Dobrescu
DDDragoș Dobrescu
Dragoș Dobrescu
SHStela Halichidis
Stela Halichidis
The origin of the photoplethysmography (PPG) signal is a debatable topic, despite plausible models being addressed. One concern revolves around the correlation between the mechanical waveform’s pulsatile nature and the associated biomechanism. The interface between these domains requires a clear mathematical or physical model that can explain physiological behavior. Describing the correct origin of the recorded optical waveform not only benefits the development of the next generation of biosensors but also defines novel health markers. In this study, the assumption of a pulsatile nature is based on the mechanism of blood microcirculation. At this level, two interconnected phenomena occur: variation in blood flow velocity through the capillary network and red blood cell (RBC) shape deformation. The latter effect was qualitatively investigated in synthetic capillaries to assess the experimental data needed for PPG model development. Erythrocytes passed through 10 µm and 6 µm microchannel widths with imposed velocities between 50 µm/s and 2000 µm/s, according to real scenarios. As a result, the length and area deformation of RBCs followed a logarithmic law function of the achieved traveling speeds. Applying radiometric expertise on top, mechanical-optical insights are obtained regarding PPG’s pulsatile nature. The mathematical equations derived from experimental data correlate microcirculation physiologic with waveform behavior at a high confidence level. The transfer function between the biomechanics and the optical signal is primarily influenced by the vasomotor state, capillary network orientation, concentration, and deformation performance of erythrocytes.