Catalin Marculescu

Dr. Catalin Marculescu

National Institute for Research and Development in Microtechnologies, Bucharest, Bucureşti, Romania
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2013 in Analytical Chemistry
Verified
Journal Article
Closed access
GTGuillaume Tresset
Guillaume Tresset
CMCatalin Marculescu
Catalin Marculescu
ASAnniina Salonen
Anniina Salonen
MNMing Ni
Ming Ni
Ciprian IliescuCiprian Iliescu
Ciprian Iliescu

29 October 2014 in Langmuir
Verified
Journal Article
Closed access
Ciprian IliescuCiprian Iliescu
Ciprian Iliescu
CMCatalin Marculescu
Catalin Marculescu
SVShrinivas Venkataraman
Shrinivas Venkataraman
BLBaptiste Languille
Baptiste Languille
HYHanry Yu
Hanry Yu
GTGuillaume Tresset
Guillaume Tresset

21 September 2022 in Gels
Verified
Journal Article
Open access
PDF file
PPPetruta Preda
Petruta Preda
AEAna-Maria Enciu
Ana-Maria Enciu
BABianca Adiaconita
Bianca Adiaconita
IMIuliana Mihalache
Iuliana Mihalache
GCGabriel Craciun
Gabriel Craciun
MAMarioara Avram
Marioara Avram
The study and discovery of bioactive compounds and new formulations as potential tools for promoting the repair of dermoepidermal tissue in wound healing is of continuing interest. We have developed a new formulation of amorphous hydrogel based on sodium alginate (NaAlg); type I collagen, isolated by the authors from silver carp tails (COL); glycerol (Gli); Aloe vera gel powder (AV); and silver nanoparticles obtained by green synthesis with aqueous Cinnamomum verum extract (AgNPs@CIN) and vitamin C, respectively. The gel texture of the amorphous hydrogels was achieved by the addition of Aloe vera, demonstrated by a rheological analysis. The evaluations of the cytotoxicity and cell proliferation capacity of the experimental amorphous hydrogels were performed against human foreskin fibroblast Hs27 cells (CRL-1634-ATCC). The developed gel formulations did not show a cytotoxic effect. The hydrogel variant containing AgNPs@CIN in a concentration of 8 µg Ag/gel formulation and hydrogel variant with vitamin C had proliferative activity. In addition, the antibacterial activity of the hydrogels was evaluated against S. aureus ATCC 6538, Ps. aeruginosa ATCC 27853, and E. coli ATCC 25922. The results demonstrated that the gel variant based on AgNPs@CIN in a concentration of 95 µg Ag/gel formulation and the hydrogel based on vitamin C show antibacterial activity. Therefore, the developed hydrogels with AgNPs@CIN and vitamin C could be promising alternatives in wound healing.

24 March 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
CMCatalin Marculescu
Catalin Marculescu
PPPetruta Preda
Petruta Preda
TBTiberiu Burinaru
Tiberiu Burinaru
ECEugen Chiriac
Eugen Chiriac
BABianca Adiaconita
Bianca Adiaconita
MAMarioara Avram
Marioara Avram
In recent research, 3D printing has become a powerful technique and has been applied in the last few years to carbon-based materials. A new generation of 3D-printed electrodes, more affordable and easier to obtain due to rapid prototyping techniques, has emerged. We propose a customizable fabrication process for flexible (and rigid) carbon-based biosensors, from biosensor design to printable conductive inks. The electrochemical biosensors were obtained on a 50 µm Kapton® (polyimide) substrate and transferred to a 500 µm PDMS substrate, using a 3D-extrusion-based printing method. The main features of our fabrication process consist of short-time customization implementation, fast small-to-medium batch production, ease of electrochemical spectroscopy measurements, and very good resolution for an extrusion-based printing method (100 µm). The sensors were designed for future integration into a smart wound dressing for wound monitoring and other biomedical applications. We increased their sensibility with electro-deposited gold nanoparticles. To assess the biosensors’ functionality, we performed surface functionalization with specific anti-N-protein antibodies for SARS-CoV 2 virus, with promising preliminary results.

4 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
BABianca Adiaconita
Bianca Adiaconita
TBTiberiu Burinaru
Tiberiu Burinaru
AEAna-Maria Enciu
Ana-Maria Enciu
PPPetruta Preda
Petruta Preda
ECEugen Chiriac
Eugen Chiriac
Marius Andrei AvramMarius Andrei Avram
Marius Andrei Avram
The selective and rapid detection of tumor cells is of critical consequence for the theragnostic field of tumorigenesis; conventional methods, such as histopathological diagnostic methods, often require a long analysis time, excessive analytical costs, complex operations, qualified personnel and deliver many false-positive results. We are considering a new approach of an electrochemical biosensor based on graphene, which is evidenced to be a revolutionary nanomaterial enabling the specific and selective capture of tumor cells. In this paper, we report a biosensor fabricated by growing vertically aligned graphene nanosheets on the conductive surface of interdigitated electrodes which is functionalized with anti-EpCAM antibodies. The dielectric signature of the three types of tumor cells is determined by correlating the values from the Nyquist and Bode diagram: charge transfer resistance, electrical double layer capacity, Debye length, characteristic relaxation times of mobile charges, diffusion/adsorption coefficients, and variation in the electrical permittivity complex and of the phase shift with frequency. These characteristics are strongly dependent on the type of membrane molecules and the electromagnetic resonance frequency. We were able to use the fabricated sensor to differentiate between three types of tumor cell lines, HT-29, SW403 and MCF-7, by dielectric signature. The proposed evaluation method showed the permittivity at 1 MHz to be 3.63 nF for SW403 cells, 4.97 nF for HT 29 cells and 6.9 nF for MCF-7 cells.

1 January 2016 in Energy Procedia
Verified
Journal Article
Open access
CMCatalin Marculescu
Catalin Marculescu
BTBianca Tincu
Bianca Tincu
Marius Andrei AvramMarius Andrei Avram
Marius Andrei Avram
TBTiberiu Burinaru
Tiberiu Burinaru
MAMarioara Avram
Marioara Avram
The present microfluidic study is emphasizing the flow behavior of two immiscible fluids within a Y shape micro-bifurcation with two inlets and one outlet. We report here a numerical investigation on the interface shape dynamics manifested at different capillary numbers (Ca), by a variation of the flow rate ratios (FRR) over the inlets. The numerical flow patterns are found to be in good agreement with the experimental manifestations. We demonstrated numerically that the Ca variation has an important impact on the droplet frequency formation. Changing only the FRR of the inlets, the droplets behavior modifies drastically. From the numerical point of view, the interface shape is used to characterize the manifestation of droplet formation